I applied via Campus Placement and was interviewed in Nov 2021. There were 3 interview rounds.
Easy basic questions
COVID-19 had a significant impact on my work as an MEP Engineer.
Worked remotely from home during lockdowns
Adapted to virtual meetings and collaboration tools
Delays in project timelines due to supply chain disruptions
Implemented safety measures on construction sites
Increased focus on indoor air quality and ventilation systems
I applied via Recruitment Consulltant and was interviewed before Aug 2022. There were 2 interview rounds.
I appeared for an interview in Mar 2022.
Landing zones are pre-defined architectures for deploying workloads in Azure.
Landing zones provide a standardized approach to deploying workloads in Azure.
They help ensure compliance with organizational policies and best practices.
Landing zones can be customized to meet specific requirements.
Examples of landing zones include the Enterprise-Scale Landing Zone and the Hub-Spoke Landing Zone.
I appeared for an interview in Mar 2022.
Assystem interview questions for popular designations
I applied via Referral and was interviewed before Apr 2022. There were 3 interview rounds.
I applied via Referral and was interviewed before Mar 2022. There were 2 interview rounds.
Cooling tower in power plant is used to remove excess heat from the water used in the cooling system.
Cooling tower helps in maintaining the temperature of water used in the cooling system.
It removes excess heat from the water and releases it into the atmosphere.
This helps in preventing overheating of the equipment and ensures efficient operation.
Examples of cooling towers include natural draft, mechanical draft, and hy
Cooling towers are used in power plants to remove excess heat from the process water.
Natural draft cooling towers
Mechanical draft cooling towers
Crossflow cooling towers
Counterflow cooling towers
Wet cooling towers
Dry cooling towers
Chimney in power plant is used to release the exhaust gases produced during the combustion process.
Chimney helps in maintaining the air quality by releasing the harmful gases at a higher altitude.
It prevents the accumulation of toxic gases in the plant and surrounding areas.
The height of the chimney is designed based on the amount of gases produced and the wind speed in the area.
Chimneys can also be equipped with scrub...
I applied via Naukri.com and was interviewed before Apr 2022. There were 2 interview rounds.
Beam column junction is a connection point between a beam and a column in a structure.
The junction should be designed to transfer loads from the beam to the column without failure.
The connection can be made using bolts, welds, or other mechanical fasteners.
The junction should be designed to resist bending, shear, and axial forces.
Proper detailing of reinforcement is necessary to ensure the strength and stability of the...
IS 1893:2016 is a code of practice for earthquake-resistant design of structures in India.
The code has been revised to include new seismic hazard maps for India
It now includes provisions for seismic design of non-structural components
The code has also introduced new seismic performance levels for buildings
It now requires consideration of soil-structure interaction effects in design
The revised code has updated provision
I applied via Naukri.com and was interviewed before May 2022. There were 3 interview rounds.
A circular pier with reinforcement detail requires a structural drawing.
The pier should be designed to withstand the loads it will bear.
The reinforcement should be placed in a way that ensures the pier's stability.
The drawing should include dimensions, materials, and placement of reinforcement.
The design should comply with local building codes and regulations.
Examples of reinforcement include steel bars, mesh, and fibe
I applied via Campus Placement and was interviewed before Nov 2021. There were 3 interview rounds.
Verbal Ability, Numerical Ability, LRDI
Bending moment calculation involves determining the internal forces acting on a beam to ensure it can withstand external loads.
Calculate the reactions at the supports of the beam
Determine the internal forces (shear force and bending moment) at different sections of the beam
Use the bending moment equation to calculate the maximum bending moment at critical sections of the beam
Consider the material properties of the beam...
I applied via Approached by Company and was interviewed before Sep 2021. There were 2 interview rounds.
Technical discussion and revit test
The duration of Assystem interview process can vary, but typically it takes about less than 2 weeks to complete.
based on 38 interviews
Interview experience
based on 642 reviews
Rating in categories
2-4 Yrs
Not Disclosed
8-9 Yrs
Not Disclosed
6-8 Yrs
Not Disclosed
Design Engineer
80
salaries
| ₹3.6 L/yr - ₹13.3 L/yr |
Assistant Design Engineer
52
salaries
| ₹3 L/yr - ₹6 L/yr |
Structural Design Engineer
50
salaries
| ₹3.3 L/yr - ₹12.5 L/yr |
Consultant Engineer
49
salaries
| ₹4.8 L/yr - ₹10 L/yr |
Senior Manager
32
salaries
| ₹12.5 L/yr - ₹32 L/yr |
Suzlon Group
Torrent Power
Eaton
Vestas