Filter interviews by
Nothing much , rest is basically technical
We have to talk on a subject for log time thats all
Speed control on motors and generators can be achieved through various methods.
For motors, speed control can be achieved by adjusting the voltage, frequency, or the number of poles.
For generators, speed control can be achieved by adjusting the mechanical input or the load connected to the generator.
In motors, variable frequency drives (VFDs) can be used to control the speed by adjusting the frequency of the power suppl...
IDFT controller stands for Inverse Discrete Fourier Transform controller.
IDFT controller is used in signal processing to convert frequency domain signals to time domain signals.
It is the inverse of the Discrete Fourier Transform (DFT) controller.
IDFT controller is commonly used in audio and video processing applications.
It is also used in communication systems to convert frequency domain signals to time domain signals ...
Top trending discussions
I applied via Company Website and was interviewed before May 2021. There was 1 interview round.
Impedance is the measure of opposition to the flow of electric current in a circuit. DGR fundamental refers to the Dielectric Withstand Voltage test.
Impedance is measured in ohms and is the combination of resistance, capacitance, and inductance in a circuit.
DGR fundamental is a test to determine the maximum voltage a material can withstand without breaking down.
Basics of impedance include understanding the relationship...
I applied via Naukri.com and was interviewed in Nov 2021. There was 1 interview round.
Impedance is the total opposition to the flow of alternating current in a circuit, while reactance is the opposition to the flow of alternating current caused by capacitance or inductance.
Impedance is a combination of resistance and reactance in a circuit.
Reactance is the opposition to the flow of alternating current caused by capacitance or inductance.
Capacitive reactance is the opposition to the flow of alternating c...
Plant load factor is calculated by dividing the actual energy generated by the maximum possible energy that could have been generated.
Plant load factor = Actual energy generated / Maximum possible energy that could have been generated
Maximum possible energy is calculated by multiplying the rated capacity of the plant with the number of hours in a given time period
Plant load factor is expressed as a percentage
It is used...
I applied via Job Portal and was interviewed before Sep 2021. There were 3 interview rounds.
I applied via Company Website and was interviewed before Jul 2022. There were 3 interview rounds.
The IR resistance of a motor refers to the insulation resistance, which measures the resistance of the insulation material surrounding the motor windings.
IR resistance is measured in ohms and indicates the ability of the insulation to prevent current leakage.
A higher IR resistance value indicates better insulation quality and less risk of electrical faults.
Regular testing of IR resistance is important to ensure the mot...
posted on 16 May 2024
I applied via Naukri.com and was interviewed in Jul 2023. There were 2 interview rounds.
Technical interview with concerned HOD
About power plants activities
based on 3 reviews
Rating in categories
Design Engineer
81
salaries
| ₹5 L/yr - ₹11 L/yr |
Structural Design Engineer
53
salaries
| ₹5.2 L/yr - ₹12.4 L/yr |
Consultant Engineer
51
salaries
| ₹4.8 L/yr - ₹9 L/yr |
Senior Engineer
35
salaries
| ₹7 L/yr - ₹12 L/yr |
Assistant Design Engineer
34
salaries
| ₹3 L/yr - ₹6 L/yr |
Suzlon Group
Torrent Power
Eaton
Vestas