Filter interviews by
General aptitude test which regularly conducted.
posted on 27 Jan 2023
I applied via Walk-in and was interviewed before Jan 2022. There were 2 interview rounds.
posted on 11 Dec 2024
I applied via Company Website and was interviewed in Nov 2024. There was 1 interview round.
To grow your career and transition to another company, focus on networking, gaining new skills, updating your resume, and preparing for interviews.
Network with professionals in your industry to learn about job opportunities
Attend industry events, conferences, and workshops to expand your knowledge and skills
Update your resume with your latest projects, achievements, and certifications
Practice for interviews by research...
Minimum diameter of bar used in column is determined by structural requirements and load calculations.
Minimum diameter is typically specified in the structural design drawings or calculations
Factors such as column height, load capacity, and seismic considerations influence the minimum bar diameter
Common minimum diameters for column bars range from 12mm to 25mm depending on the structural requirements
Minimum grade of concrete used in column is typically M20.
Minimum grade of concrete used in column is usually M20
Higher grades like M25, M30, M35, etc. can also be used for columns based on structural requirements
The grade of concrete is determined based on the strength required for the structure
Minimum thickness of slab is determined based on factors like load, span, and material used.
Minimum thickness of slab is typically determined by structural engineers based on the expected loads and span of the slab.
Factors such as the material used for the slab and any additional reinforcement also play a role in determining the minimum thickness.
For example, a residential slab may have a minimum thickness of 4 inches,...
Water cement ratio is the ratio of the weight of water to the weight of cement used in a concrete mix.
Water cement ratio is a crucial factor in determining the strength and durability of concrete.
A lower water cement ratio results in stronger and more durable concrete.
The ideal water cement ratio varies depending on the type of concrete mix and its intended use.
For example, a typical water cement ratio for general purp
The density of steel is approximately 7.85 g/cm^3.
The density of steel is commonly expressed in grams per cubic centimeter (g/cm^3).
The density of steel can vary slightly depending on the specific alloy and composition.
For example, the density of stainless steel is around 7.9 g/cm^3, while carbon steel is around 7.85 g/cm^3.
What is the colume
The vertical part of the building and base of the slab, distribution of load
Cracks in beams typically develop at locations of high stress concentrations or due to external factors like corrosion.
Cracks can develop at the supports of the beam where the bending moment is highest.
Cracks can also form at locations where there are changes in cross-section or material properties.
External factors like corrosion can lead to cracks in beams over time.
Cracks may also develop at locations where there are...
Different types of slab concrete testing include slump test, air content test, compressive strength test, and flexural strength test.
Slump test measures the consistency and workability of concrete.
Air content test determines the amount of air trapped in the concrete mixture.
Compressive strength test assesses the ability of concrete to withstand loads.
Flexural strength test evaluates the bending strength of concrete.
posted on 20 Aug 2024
Concrete grade directly affects the development length of reinforcement bars in a structure.
Higher concrete grades typically require longer development lengths for reinforcement bars to achieve the desired bond strength.
Lower concrete grades may allow for shorter development lengths, but may compromise the overall strength and durability of the structure.
Development length is influenced by factors such as bar diameter,...
posted on 3 Jul 2024
I applied via Approached by Company and was interviewed in Jun 2024. There was 1 interview round.
The top diameter of a slump cone is typically 4 inches.
The top diameter of a slump cone is usually 4 inches.
The slump cone is used to measure the consistency of fresh concrete.
The top diameter of the slump cone affects the flow of the concrete mix.
A larger top diameter will result in a higher slump value.
Thermo-Mechanically Treated
TMT stands for Thermo-Mechanically Treated
TMT bars are commonly used in construction for reinforcement
The process involves heating the steel bars and then rapidly cooling them to increase their strength
posted on 6 May 2024
I applied via Naukri.com and was interviewed in Apr 2024. There were 2 interview rounds.
Civil engineers work with a variety of materials including concrete, steel, asphalt, and wood.
Common materials used in civil engineering include concrete, steel, asphalt, wood, and aggregates.
Concrete is used for foundations, roads, and structures.
Steel is used for beams, columns, and reinforcement.
Asphalt is used for roads and pavements.
Wood is used for formwork, bridges, and buildings.
Aggregates are used in concrete
Assistant Engineer
19
salaries
| ₹2 L/yr - ₹4.6 L/yr |
Assistant Manager
5
salaries
| ₹1.8 L/yr - ₹5.2 L/yr |
Engineer
5
salaries
| ₹1.9 L/yr - ₹3.7 L/yr |
Diploma Mechanical Engineer
4
salaries
| ₹2 L/yr - ₹2 L/yr |
Assistant Quality Engineer
4
salaries
| ₹2 L/yr - ₹6.5 L/yr |
L&T Technology Services
TCS
Wipro
HCLTech