i
Sterling & Wilson
Filter interviews by
I applied via Approached by Company and was interviewed in Jun 2024. There was 1 interview round.
The top diameter of a slump cone is typically 4 inches.
The top diameter of a slump cone is usually 4 inches.
The slump cone is used to measure the consistency of fresh concrete.
The top diameter of the slump cone affects the flow of the concrete mix.
A larger top diameter will result in a higher slump value.
Thermo-Mechanically Treated
TMT stands for Thermo-Mechanically Treated
TMT bars are commonly used in construction for reinforcement
The process involves heating the steel bars and then rapidly cooling them to increase their strength
Top trending discussions
posted on 21 Apr 2024
I applied via Approached by Company and was interviewed before Apr 2023. There was 1 interview round.
I was interviewed in Jan 2025.
I was interviewed in Jan 2025.
I am currently working at a construction company specializing in infrastructure projects.
Specializing in infrastructure projects
Working at a construction company
Dealing with civil engineering tasks
I have 5 years of experience working on various civil engineering projects, including site development, infrastructure design, and construction management.
Managed site development projects from concept to completion
Designed infrastructure systems such as water supply and drainage
Performed construction management duties to ensure projects stayed on schedule and within budget
Worked on projects ranging from residential de...
Handling a site in the transmission sector involves coordinating with various stakeholders, ensuring compliance with regulations, and overseeing the construction process.
Coordinate with utility companies to ensure proper installation of transmission lines
Ensure compliance with safety regulations and environmental standards
Oversee the construction process to ensure quality and timely completion
Manage and resolve any iss...
Key considerations for foundation in transmission line construction
Soil type and bearing capacity must be assessed
Proper foundation design to support the weight and wind loads of the transmission line towers
Consideration of environmental factors such as seismic activity and flooding
Accessibility for construction equipment and maintenance
Proper drainage to prevent erosion and foundation instability
The best method for erection in transmission is using cranes and specialized equipment.
Use cranes for lifting and placing heavy transmission components
Ensure proper planning and coordination to avoid delays
Utilize specialized equipment for precise positioning
Follow safety protocols to prevent accidents
Consider environmental factors such as wind and terrain
I adapt to challenging situations by staying calm, analyzing the problem, seeking advice from colleagues, and coming up with creative solutions.
Stay calm and composed under pressure
Analyze the problem thoroughly before taking action
Seek advice and input from colleagues or experts
Think creatively to come up with innovative solutions
The diagonal in the transmission sector plays a crucial role in providing structural stability and support to the transmission towers.
The diagonal members in transmission towers help to distribute the load and provide stability against wind and seismic forces.
They prevent the tower from buckling or collapsing under various loads.
Diagonals also help in reducing the overall weight of the tower by transferring some of the...
posted on 6 Feb 2025
Designing beams and columns involves determining the size, material, and layout to support the required loads.
Consider the type of structure and the loads it will bear
Calculate the required dimensions and reinforcement based on structural analysis
Select appropriate materials such as steel or concrete
Ensure proper connections and detailing for stability and safety
Limit state of serviceability refers to the condition where a structure is still functioning properly without any excessive deflection or deformation.
Limit state of serviceability ensures that a structure remains usable and safe for occupants.
It involves checking factors like deflection, vibration, cracking, and durability.
For example, a bridge should not deflect excessively under the weight of traffic to maintain serv...
What is the colume
The vertical part of the building and base of the slab, distribution of load
posted on 19 Jan 2024
I applied via Naukri.com and was interviewed in Dec 2023. There was 1 interview round.
posted on 14 Feb 2024
posted on 1 Aug 2024
I applied via Recruitment Consulltant and was interviewed in Feb 2024. There were 2 interview rounds.
As usual simple question.
Software test like ms office suit ad auto cad.
based on 1 interview
Interview experience
based on 1 review
Rating in categories
Electrical Engineer
270
salaries
| ₹1.8 L/yr - ₹8.4 L/yr |
Senior Engineer
246
salaries
| ₹3.1 L/yr - ₹9.1 L/yr |
Project Engineer
212
salaries
| ₹2.4 L/yr - ₹8.5 L/yr |
Assistant Manager
165
salaries
| ₹4.7 L/yr - ₹17 L/yr |
Manager
137
salaries
| ₹7.3 L/yr - ₹23.6 L/yr |
Larsen & Toubro Limited
Tata Power
Thermax Limited
BHEL