Filter interviews by
I am a trainee at XYZ Company, currently working on various projects under the guidance of senior team members.
Trainee at XYZ Company
Working on various projects
Under the guidance of senior team members
I am a dedicated and hardworking individual with a passion for learning and growth.
I have a strong work ethic and am always eager to take on new challenges.
I am a quick learner and adapt well to new environments.
I am detail-oriented and strive for excellence in everything I do.
I applied via Naukri.com and was interviewed in Oct 2024. There was 1 interview round.
Manpower nhandling only
Petrofac interview questions for popular designations
Transformers are rated in kVA because it indicates the maximum amount of power that can be safely handled by the transformer.
kVA rating is used to determine the maximum load that a transformer can handle without overheating.
It takes into account both the voltage and current ratings of the transformer.
kVA rating helps in selecting the right size of transformer for a specific application.
For example, a 100 kVA transforme...
MCCB stands for Molded Case Circuit Breaker.
MCCB is a type of circuit breaker that is commonly used in electrical distribution systems.
It provides protection against overcurrent and short circuit faults.
MCCBs have adjustable trip settings for different levels of current protection.
Examples of MCCB manufacturers include Schneider Electric, Siemens, and ABB.
Get interview-ready with Top Petrofac Interview Questions
I applied via Company Website and was interviewed in Jun 2023. There were 3 interview rounds.
Graph based question. Duration: 45 mins
Various sensors used in oil and gas industries include pressure sensors, temperature sensors, flow sensors, level sensors, and gas detectors.
Pressure sensors - used to measure pressure in pipelines and equipment.
Temperature sensors - monitor temperature levels in various processes.
Flow sensors - measure the flow rate of liquids or gases in pipelines.
Level sensors - detect the level of liquids in tanks or vessels.
Gas de...
HAZOP stands for Hazard and Operability Study, while HAZID stands for Hazard Identification.
HAZOP is a systematic method to identify potential hazards and operability issues in a process plant.
HAZID is a process used to identify hazards in a facility or operation before they become accidents.
Both HAZOP and HAZID are important tools in risk assessment and management in engineering projects.
P, PI, PID are types of controllers used in process control to regulate the output based on the input.
P stands for Proportional controller, which adjusts the output based on the error signal.
PI stands for Proportional-Integral controller, which not only adjusts based on error signal but also integrates the error over time.
PID stands for Proportional-Integral-Derivative controller, which adjusts based on error signal, i...
Digital Electronics is a branch of electronics that deals with digital signals and systems.
Deals with digital signals (0s and 1s)
Involves logic gates, flip-flops, and digital circuits
Used in computers, calculators, digital watches, etc.
Binary arithmetic and Boolean algebra are fundamental concepts
Level sensor, flow sensor, and temperature sensor are devices used to measure different physical parameters in various industries.
Level sensor measures the level of a substance in a container or tank, such as liquid level sensors in water tanks.
Flow sensor measures the flow rate of a fluid, like a flow meter in a pipeline.
Temperature sensor measures the temperature of a system or environment, for example, a thermocoupl
Saudi Aramco Engineering Standards are guidelines and specifications used in engineering projects for Saudi Aramco.
Saudi Aramco Engineering Standards cover various aspects of engineering design, materials, construction, and operation.
These standards ensure consistency, quality, and safety in all engineering projects undertaken by Saudi Aramco.
Examples of areas covered by the standards include piping design, electrical ...
Safe practices in design involve considering potential hazards, following regulations, and prioritizing safety.
Identify potential hazards in the design process
Follow industry regulations and standards for safety
Prioritize safety over cost or convenience
Regularly review and update safety protocols
Include safety features in the design, such as emergency shut-off valves
Consider environmental impact and sustainability in d
Quality of deliverables is crucial for successful project completion.
Ensuring accuracy and completeness of drawings and documents
Adhering to project specifications and standards
Regularly reviewing and revising deliverables to meet client requirements
Seeking feedback from stakeholders to improve quality
Using software tools effectively to enhance deliverables
Maintaining clear communication with team members for consisten
posted on 9 Jul 2024
I applied via LinkedIn and was interviewed before Jul 2023. There was 1 interview round.
I applied via Walk-in and was interviewed in Jul 2023. There were 3 interview rounds.
Pressure drop criteria for liquid and vapor phases are essential for accurate hydraulic calculations.
Pressure drop criteria for liquid phase typically range from 0.5-2 psi per 100 feet of pipe length.
Pressure drop criteria for vapor phase can vary depending on the specific application and design parameters.
Factors such as flow rate, pipe diameter, fluid properties, and equipment specifications must be considered when d...
Top trending discussions
Interview experience
based on 865 reviews
Rating in categories
Senior Engineer
64
salaries
| ₹10 L/yr - ₹30 L/yr |
Principal Engineer
60
salaries
| ₹12 L/yr - ₹36 L/yr |
Senior Design Engineer
47
salaries
| ₹8 L/yr - ₹21.5 L/yr |
Instrument Engineer
35
salaries
| ₹10.3 L/yr - ₹25 L/yr |
Process Engineer
34
salaries
| ₹7 L/yr - ₹22 L/yr |
L&T Energy Hydrocarbon
TechnipFMC
McDermott International
Saipem