I applied via Recruitment Consultant and was interviewed before Jun 2019. There were 3 interview rounds.
Reciprocating compressor 1st stage pressure increase - reason and troubleshooting
Possible reasons: clogged suction filter, worn out piston rings, valve failure, incorrect valve timing, inadequate lubrication
Troubleshooting steps: check suction filter, inspect piston rings and valves, adjust valve timing, ensure proper lubrication
If issue persists, consult manufacturer's manual or seek professional help
Different types of pumps and their parts with sectional drawings.
Centrifugal pumps have impellers, volutes, and shafts.
Positive displacement pumps have gears, lobes, and vanes.
Diaphragm pumps have diaphragms, check valves, and ball valves.
Sectional drawings show the internal parts of a pump.
Pumps can be classified based on their application, such as water pumps, fuel pumps, and chemical pumps.
Alignment of pump and driver coupling is crucial for efficient operation and to prevent damage.
Proper alignment ensures smooth power transmission between the pump and driver.
Misalignment can lead to excessive vibration, premature wear, and reduced efficiency.
Alignment can be achieved through various methods such as laser alignment or dial indicators.
Alignment should be checked regularly and adjusted if necessary.
Exampl...
DBS in coupling refers to the distance between the two shafts.
DBS stands for Distance Between Shafts.
It is the distance between the two shafts in a coupling.
It is an important parameter to consider while selecting a coupling.
The DBS value is usually provided by the coupling manufacturer.
It helps in ensuring proper alignment and avoiding misalignment issues.
Top trending discussions
posted on 18 Jan 2018
I applied via Referral and was interviewed before Jan 2017. There were 3 interview rounds.
Yes, it is comfortable to transfer all over INDIA.
As an electrical engineer, I am trained to work in various locations.
I am adaptable and can easily adjust to different environments and cultures.
I have experience working on projects in different states of India.
I am willing to travel and relocate as required for the job.
posted on 18 Jan 2018
posted on 3 Jun 2018
I applied via Other and was interviewed in Jan 2018. There were 5 interview rounds.
posted on 6 Nov 2020
I applied via Campus Placement and was interviewed before Nov 2019. There were 3 interview rounds.
posted on 30 Mar 2022
I applied via Newspaper Ad and was interviewed before Mar 2021. There were 2 interview rounds.
Basic aptitude and mathematics
posted on 4 May 2019
I applied via Approached by Company and was interviewed in Oct 2018. There were 5 interview rounds.
posted on 12 May 2018
I applied via Recruitment Consultant and was interviewed in Jan 2018. There were 5 interview rounds.
I applied via Naukri.com and was interviewed in May 2021. There was 1 interview round.
posted on 3 May 2022
I applied via Naukri.com and was interviewed before May 2021. There was 1 interview round.
Various types of valves are used in chemical industries for different purposes.
Gate valves are commonly used in chemical industries for on/off control of flow.
Globe valves are used for regulating flow and controlling pressure.
Ball valves are suitable for high-pressure applications and provide tight shut-off.
Butterfly valves are used for throttling and controlling flow.
Diaphragm valves are used for handling corrosive an...
Some of the top questions asked at the Petrofac Mechanical Maintenance Supervisor interview -
based on 1 review
Rating in categories
Senior Engineer
65
salaries
| ₹0 L/yr - ₹0 L/yr |
Principal Engineer
61
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Design Engineer
49
salaries
| ₹0 L/yr - ₹0 L/yr |
Instrument Engineer
35
salaries
| ₹0 L/yr - ₹0 L/yr |
Process Engineer
33
salaries
| ₹0 L/yr - ₹0 L/yr |
L&T Energy Hydrocarbon
TechnipFMC
McDermott International
Saipem