i
H.G. Infra Engineering
Proud winner of ABECA 2024 - AmbitionBox Employee Choice Awards
Filter interviews by
I applied via Referral and was interviewed before Aug 2021. There was 1 interview round.
I applied via Approached by Company and was interviewed before Apr 2022. There were 3 interview rounds.
posted on 8 Jul 2024
Structures are framed by designing a skeleton of beams and columns to support the load.
Start by determining the loads the structure will need to support.
Design a skeleton of beams and columns to distribute the load.
Consider factors such as material strength, stability, and aesthetics.
Use software like AutoCAD or Revit to create detailed plans and drawings.
Consult with architects and other engineers to ensure the struct
The value for shape mode represents the most frequently occurring value in a dataset.
Shape mode is the value that appears most frequently in a dataset.
It is used to describe the central tendency of a dataset.
For example, in a dataset of test scores, if the score of 85 appears most frequently, then 85 is the shape mode.
posted on 24 Dec 2023
I applied via Walk-in and was interviewed in Nov 2023. There were 3 interview rounds.
The IS code for structures in India is IS 456:2000, which covers the general requirements for the design and construction of reinforced concrete structures.
The IS code for structures in India is IS 456:2000
It covers the general requirements for the design and construction of reinforced concrete structures
The code provides guidelines for materials, design, construction, quality control, and maintenance of structures
posted on 17 Mar 2021
I applied via Naukri.com and was interviewed in Sep 2020. There were 3 interview rounds.
The density of steel is approximately 7.85 grams per cubic centimeter.
The density of steel is commonly measured in grams per cubic centimeter (g/cm³).
The density of steel can vary depending on the specific type and composition of the steel.
For example, the density of carbon steel is typically around 7.85 g/cm³.
Stainless steel, on the other hand, has a slightly lower density of around 7.9 g/cm³.
The density of steel is a...
The density of RCC (Reinforced Cement Concrete) and PCC (Plain Cement Concrete) varies depending on the mix proportions.
The density of RCC typically ranges from 2200 to 2500 kg/m³.
The density of PCC generally ranges from 2200 to 2400 kg/m³.
The density can vary based on the type and size of aggregates used, the water-cement ratio, and the presence of additives.
For example, a mix with a higher proportion of aggregates wi...
BBS stands for Bar Bending Schedule. It is a document that provides details of reinforcement steel bars required for a construction project.
BBS is calculated based on the design drawings and specifications.
It includes details such as bar diameter, length, shape, and number of bars required for each structural element.
BBS helps in estimating the quantity of steel required and also ensures that the reinforcement is place...
I have executed various types of structures including high-rise buildings, bridges, and industrial facilities.
Executed high-rise buildings with complex structural systems
Designed and analyzed bridges with different span lengths and types of materials
Managed the structural design of industrial facilities such as power plants and manufacturing plants
Worked on retrofitting and rehabilitation of existing structures
Collabor...
posted on 26 Aug 2023
I applied via Recruitment Consulltant and was interviewed in Jul 2023. There were 2 interview rounds.
The bolt to bolt distance depends on the specific design requirements and standards for the structural connection.
The bolt to bolt distance is typically specified in the design drawings or calculations provided by the engineer.
It is important to follow the recommended bolt to bolt distance to ensure the structural integrity of the connection.
The bolt to bolt distance may vary depending on factors such as the size and t...
Edge distance refers to the distance between the edge of a structural member and the center of a hole or fastener.
Edge distance is typically specified in design codes and standards.
It is important to maintain adequate edge distance to prevent failure of the connection.
The required edge distance can vary depending on the type of connection and the loading conditions.
For example, in steel connections, the minimum edge di...
The type of weld used for connecting a column to a base plate is typically a fillet weld.
Fillet welds are commonly used for connecting structural steel components.
The size of the fillet weld is determined based on the forces and stresses the connection will experience.
Proper welding procedures and inspections are essential to ensure the weld's quality and strength.
Column to beam joints are typically connected using various methods such as welding, bolting, or using mechanical connectors.
Common methods for connecting column to beam include welding, bolting, or using mechanical connectors
Welding is a common method where the column and beam are fused together using heat
Bolting involves using bolts to secure the column and beam together
Mechanical connectors such as shear connectors ...
The top moment column to beam top side is typically welded on the compression side of the beam.
Weld the top moment connection on the compression side of the beam for maximum strength.
Ensure proper welding techniques and inspections are followed to maintain structural integrity.
Consider using fillet welds or groove welds depending on the design requirements.
Consult structural engineering codes and standards for specific...
Edge distance of 75mm is required to cover vertical reinforcement in all types of foundations.
Edge distance is important to ensure proper anchorage and structural integrity of the reinforcement.
In this case, a minimum edge distance of 75mm is specified for covering vertical reinforcement in all types of foundations.
Examples of foundations where this requirement applies include spread footings, pile caps, and mat founda
posted on 10 May 2024
I applied via Campus Placement and was interviewed before May 2023. There was 1 interview round.
posted on 16 Feb 2022
I applied via Company Website and was interviewed in Jan 2022. There were 2 interview rounds.
The volume of concrete refers to the amount of space occupied by concrete.
Volume of concrete is measured in cubic units (e.g., cubic meters or cubic feet).
It is calculated by multiplying the length, width, and height of the concrete element.
For example, if a concrete slab has a length of 5 meters, width of 3 meters, and height of 0.15 meters, the volume of concrete would be 5 x 3 x 0.15 = 2.25 cubic meters.
I applied via campus placement at Birla Institute of Technology and Science (BITS), Pilani and was interviewed in Jul 2024. There were 3 interview rounds.
Social media connecting people
Sfd and bmd diagrams show the variation of shear force and bending moment along the length of a structural member.
SFD (Shear Force Diagram) shows the variation of shear force along the length of a beam or structural member.
BMD (Bending Moment Diagram) shows the variation of bending moment along the length of a beam or structural member.
SFD and BMD are essential for analyzing the internal forces and moments in a structu...
I am a structural engineer with 5 years of experience in designing and analyzing buildings and bridges.
Graduated with a degree in Civil Engineering
Worked on various projects including high-rise buildings and pedestrian bridges
Proficient in software such as AutoCAD and SAP2000
I am open to job locations that offer opportunities for growth and development.
I am willing to relocate for the right job opportunity
I prefer job locations with good transportation options
I am open to both urban and rural locations depending on the job requirements
Base plate design involves determining the size, thickness, and material of the plate to support the structural load.
Consider the load requirements and dimensions of the column being supported
Calculate the required thickness and size of the base plate based on the load
Select a suitable material for the base plate, such as steel or concrete
Ensure proper anchorage and connection details for the base plate
A base plate connection is a structural element used to connect a steel column to a concrete foundation.
Base plate connections are typically used in steel structures to transfer loads from the column to the foundation.
The base plate is usually welded to the bottom of the column and anchored to the concrete foundation using anchor bolts.
The base plate connection design must consider factors such as load transfer, bendin...
based on 5 reviews
Rating in categories
Assistant Manager
107
salaries
| ₹4.2 L/yr - ₹12 L/yr |
Senior Engineer
82
salaries
| ₹4.1 L/yr - ₹8.7 L/yr |
Assistant Engineer
82
salaries
| ₹2.4 L/yr - ₹4.5 L/yr |
Structural Engineer
66
salaries
| ₹2.6 L/yr - ₹5.4 L/yr |
Engineer
59
salaries
| ₹2.5 L/yr - ₹6.8 L/yr |
Ashoka Buildcon
IRB Infrastructure
Nagarjuna Construction Company
PNC Infratech