Filter interviews by
Concrete is checked at site through various methods to ensure its quality and strength.
Visual inspection of concrete surface
Slump test to check consistency
Compression test to check strength
Ultrasonic testing to detect defects
Core testing to check strength and uniformity
Rebound hammer test to check surface hardness
Temperature monitoring during curing process
Checking for proper mix proportions and curing conditions
Verifi...
Free fall in concrete refers to the process of pouring concrete without any external force to assist in its placement.
Free fall is a method of placing concrete where it is allowed to fall from the mixer truck or pump without any external force.
This method is used for small jobs or in areas where access is limited.
It can result in segregation and air pockets in the concrete if not properly managed.
Free fall height shoul...
Grade of concrete refers to the strength of the concrete mix.
Grade of concrete is denoted by the ratio of cement, sand, and aggregate used in the mix.
The strength of concrete increases with the increase in the grade of concrete.
For example, M20 grade of concrete means the mix contains 1 part cement, 1.5 parts sand, and 3 parts aggregate.
Higher grade of concrete is used for structures that require higher strength, such
Select fill material is a type of soil used to fill in areas where the ground needs to be raised or leveled.
Select fill material is typically composed of clay, sand, and gravel.
It is used in construction projects to create a stable base for buildings, roads, and other structures.
The material is carefully selected and tested to ensure it meets specific engineering requirements.
Examples of select fill material include cr...
Embedded length is the length of a reinforcing bar that is embedded in concrete.
It is the length of a reinforcing bar that is embedded in concrete
It is used to provide anchorage to the reinforcement in the concrete
The length is determined by the diameter of the bar and the strength of the concrete
It is important to ensure that the embedded length is sufficient to prevent failure of the structure
I applied via Recruitment Consulltant and was interviewed in Mar 2023. There were 2 interview rounds.
Safety in design refers to the process of incorporating safety measures and considerations into the design of a structure or system.
Safety in design involves identifying potential hazards and risks and implementing measures to mitigate them.
It includes considering factors such as fire safety, structural integrity, accessibility, and emergency evacuation.
Designing with safety in mind can prevent accidents, injuries, and...
I applied via Campus Placement and was interviewed in Feb 2023. There were 2 interview rounds.
Power factor is the ratio of real power to apparent power in an AC circuit.
Power factor is a measure of how efficiently electrical power is being used.
It is expressed as a decimal or a percentage.
A power factor of 1 means all the power is being used efficiently.
A power factor less than 1 means some power is being wasted.
Inductive loads like motors have a lagging power factor while capacitive loads like transformers hav
Types of motors: AC motors, DC motors, stepper motors. Types of switchgear protection: fuses, circuit breakers, relays.
AC motors: used in high power applications, such as industrial machinery and air conditioning systems
DC motors: used in low power applications, such as toys and small appliances
Stepper motors: used in precision applications, such as robotics and 3D printers
Fuses: protect electrical circuits from overlo...
I applied via Recruitment Consulltant and was interviewed before May 2022. There were 2 interview rounds.
I have handled testing of various electrical equipment including transformers, switchgears, motors, generators, and control panels.
Testing of transformers for insulation resistance, winding resistance, turns ratio, and polarity
Testing of switchgears for insulation resistance, contact resistance, and operation
Testing of motors for insulation resistance, winding resistance, and no-load and load testing
Testing of generato...
DAR Engineering interview questions for popular designations
I applied via Naukri.com and was interviewed before Jan 2022. There were 2 interview rounds.
I have a strong technical knowledge about pipeline design, construction, and maintenance.
I am familiar with different types of pipelines such as oil, gas, water, and sewage pipelines.
I have experience in designing pipeline routes, selecting materials, and calculating pressure drops.
I am knowledgeable about pipeline construction techniques, including welding, trenching, and backfilling.
I am skilled in pipeline inspectio...
Bar bending schedule is a document that provides details of reinforcement steel bars used in construction.
It includes information like bar diameter, length, shape, and number of bars required for each structural element.
It helps in estimating the quantity of steel required for a project and ensures that the reinforcement is placed correctly.
It is prepared by a structural engineer or a detailer and is used by the site e...
I was interviewed before Aug 2016.
Switchgear is a combination of electrical disconnect switches, fuses, or circuit breakers used to control, protect, and isolate electrical equipment.
Switchgear is a general term for a collection of devices used to control, protect, and isolate electrical equipment.
Circuit breakers are a type of switchgear that automatically interrupts the flow of electric current when a fault is detected.
Switchgear can include disconne...
The interface between transformer and switch gears is the electrical connection and communication between the two components.
The transformer and switch gears are connected through electrical cables or busbars.
The switch gears control the flow of electrical power to and from the transformer.
The switch gears may include circuit breakers, relays, and protective devices.
The interface ensures proper coordination and protect...
The value of IBL of Transformer oil is the Insulating Breakdown Level.
IBL is a measure of the dielectric strength of transformer oil.
It indicates the maximum voltage that the oil can withstand before it breaks down and loses its insulating properties.
The IBL value is important for ensuring the safe and reliable operation of transformers.
Regular testing of transformer oil is necessary to monitor the IBL and detect any p...
I am currently earning $80,000 and I am looking for a salary in the range of $90,000 to $100,000.
My current salary is $80,000.
I am expecting a salary in the range of $90,000 to $100,000.
I am open to negotiation based on the overall compensation package.
Yes, I am ready for re-location.
I am open to moving to a new location for the right opportunity.
I have experience working in different cities and adapting to new environments.
I am willing to relocate to further my career and gain new experiences.
I understand the challenges that come with re-location and I am prepared to face them.
I have a flexible mindset and can easily adjust to new surroundings.
Negotiation is typically done before arrival to finalize terms and conditions.
Negotiations are usually conducted before the candidate arrives to ensure all terms are agreed upon in advance.
It is important to have a clear understanding of the offer and terms before accepting the job.
Discussing and finalizing details beforehand can help avoid misunderstandings or conflicts later on.
Top trending discussions
posted on 29 Feb 2024
I applied via Recruitment Consulltant and was interviewed before Feb 2023. There was 1 interview round.
Single Line Diagram (SLD) is used to identify different symbols in electrical engineering.
SLD is a simplified representation of a power system using various symbols to represent different components.
Common symbols in SLD include transformers, circuit breakers, switches, motors, generators, etc.
Each symbol in SLD has a specific meaning and helps in understanding the layout of the electrical system.
Color coding and label...
Switchgear selection process involves evaluating electrical requirements, environmental conditions, and safety standards to choose the appropriate equipment.
Evaluate electrical requirements such as voltage, current, and fault levels
Consider environmental conditions like temperature, humidity, and altitude
Ensure compliance with safety standards such as ANSI, IEEE, and IEC
Select the appropriate type of switchgear based o...
I applied via Company Website and was interviewed in Apr 2022. There were 3 interview rounds.
I was interviewed in Apr 2023.
based on 6 interviews
Interview experience
based on 73 reviews
Rating in categories
Architect
9
salaries
| ₹0 L/yr - ₹0 L/yr |
Electrical Engineer
8
salaries
| ₹0 L/yr - ₹0 L/yr |
BIM Modeller
7
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Architect
6
salaries
| ₹0 L/yr - ₹0 L/yr |
Electrical Project Engineer
5
salaries
| ₹0 L/yr - ₹0 L/yr |
TCE
Mecon
L&T Technology Services
AECOM