Filter interviews by
I applied via Naukri.com
Foundation footing requires a minimum cover of 50mm to 75mm for reinforcement protection.
Minimum cover of 50mm to 75mm is required for foundation footing to protect the reinforcement from corrosion and provide adequate strength.
The cover requirement may vary based on the type of soil, environmental conditions, and structural design.
Proper cover ensures durability and stability of the foundation.
In some cases, additiona...
The cover required for shuttering column up to FFL depends on the type of concrete being used and the environmental conditions.
Cover required for shuttering column up to FFL typically ranges from 25mm to 50mm.
Factors such as type of concrete mix, exposure conditions, and structural requirements can influence the required cover.
For example, in harsh environmental conditions or high-strength concrete, a higher cover may ...
Top trending discussions
posted on 20 Aug 2023
I applied via Recruitment Consulltant and was interviewed before Aug 2022. There were 3 interview rounds.
Understanding of steel types and grades, development length, BBS, concrete testing, IS codes, de-shuttering time, mix design, admixtures, etc.
Steel types and grades like Fe550 and Fe550D differ in their ductility and strength properties
Development length is the length of bar required for full development of stress in reinforcement
BBS (Bar Bending Schedule) is a detailed list of reinforcement bars with their shapes, siz...
If compressive strength test of concrete fails, investigate potential causes like incorrect mix proportions or curing methods. Testing at 3, 7, and 28 days allows for monitoring strength development over time.
Investigate potential causes of failure such as incorrect mix proportions, improper curing methods, or testing errors
Consider retesting samples to confirm results and identify any discrepancies
Testing at 3 days pr...
posted on 21 Apr 2024
I applied via Approached by Company and was interviewed before Apr 2023. There was 1 interview round.
posted on 7 May 2023
I applied via Naukri.com and was interviewed before May 2022. There were 2 interview rounds.
posted on 19 Aug 2024
I applied via Walk-in and was interviewed in Jul 2024. There was 1 interview round.
posted on 6 Jun 2024
I applied via Walk-in and was interviewed in May 2024. There were 2 interview rounds.
The type of steel used in slabs is typically reinforced steel bars, also known as rebar.
Reinforced steel bars are commonly used in slabs to provide tensile strength and prevent cracking.
Different grades of steel can be used depending on the structural requirements of the slab.
Examples of steel types used in slabs include ASTM A615 Grade 60 and ASTM A706 Grade 60 rebar.
posted on 2 Oct 2024
The size of a concrete cube is typically 150mm x 150mm x 150mm for standard testing purposes.
Standard size for concrete cube is 150mm x 150mm x 150mm
Used for testing the compressive strength of concrete
Other sizes may be used for specific projects or requirements
posted on 14 Feb 2024
I applied via Naukri.com and was interviewed in Jul 2023. There were 3 interview rounds.
The slope of stairs refers to the angle at which the stairs are inclined, affecting safety and accessibility.
The slope of stairs is typically between 30-35 degrees for comfortable and safe use.
Building codes may dictate specific slope requirements for stairs to ensure safety and accessibility.
The slope of stairs can be calculated using trigonometry, with the rise and run of the stairs determining the angle.
A steep slop...
Covering is provided in steel reinforcement to protect it from corrosion and to ensure proper bond with concrete.
Covering protects steel reinforcement from corrosion caused by exposure to moisture and chemicals in the environment.
It helps in maintaining the bond between steel reinforcement and concrete, ensuring structural integrity.
Proper covering thickness is important to prevent rusting of steel bars and maintain du...
The leaping zone of steel reinforcement refers to the area where the steel bars are not provided in a concrete member.
The leaping zone is typically found in beams and slabs where the steel reinforcement is not required to be continuous.
It is important to ensure that the leaping zone does not compromise the structural integrity of the member.
Proper detailing and design considerations are necessary to determine the exten...
Site uses materials can be identified through visual inspection, testing, and documentation.
Conduct visual inspection of materials on site to identify their type and quality
Perform tests on materials such as soil, concrete, and asphalt to determine their properties
Review documentation such as material specifications, delivery receipts, and quality control reports
Consult with suppliers and manufacturers to verify the au
A section of stairs case with reinforcement is a structural drawing showing the details of the stairs and the reinforcement bars used for strength.
Include dimensions and materials used for the stairs and reinforcement bars
Show the arrangement of reinforcement bars in the section view
Label the different components of the stairs case for clarity
Maivan technology consists of various components including sensors, software, and data analytics for monitoring and managing civil infrastructure.
Sensors are used to collect data on various parameters such as temperature, humidity, and structural integrity.
Software is utilized to process the data collected by sensors and provide real-time monitoring and analysis.
Data analytics tools are employed to identify patterns, t...
Interview experience
Assistant Manager
271
salaries
| ₹5.4 L/yr - ₹14.2 L/yr |
Civil Engineer
183
salaries
| ₹2.4 L/yr - ₹9.3 L/yr |
Senior Engineer
179
salaries
| ₹3.8 L/yr - ₹10.2 L/yr |
Deputy Manager
169
salaries
| ₹7.5 L/yr - ₹18 L/yr |
Engineer
168
salaries
| ₹2.6 L/yr - ₹8 L/yr |
Larsen & Toubro Limited
Shapoorji Pallonji Group
Hindustan Construction Company
Simplex Infrastructures