Filter interviews by
I applied via Recruitment Consulltant and was interviewed before Oct 2022. There were 3 interview rounds.
I have 3 years of experience in sheet metal work, including designing and fabricating components for various projects.
Experience in designing sheet metal components using CAD software
Knowledge of different types of sheet metal materials and their properties
Hands-on experience in fabricating sheet metal parts using various tools and techniques
Ability to interpret engineering drawings and specifications accurately
Experie...
I was interviewed in Apr 2021.
I applied via Walk-in and was interviewed in Mar 2024. There was 1 interview round.
CT current can be calculated by dividing the primary current by the turns ratio of the current transformer.
CT current = Primary current / Turns ratio
Primary current is the current flowing through the primary conductor
Turns ratio is the ratio of the number of turns in the primary winding to the number of turns in the secondary winding
Lockout is a safety procedure used to ensure that machinery or equipment is properly shut off and cannot be restarted until maintenance or servicing is completed.
Lockout involves isolating energy sources to prevent accidental startup.
Lockout devices like padlocks and tags are used to physically lock equipment.
Lockout procedures must be followed to prevent accidents and injuries.
Examples of lockout include locking out e...
IP65 for panel refers to the level of protection against dust and water ingress.
IP65 rating means the panel is dust tight and protected against water jets from any direction.
The first digit '6' indicates the level of protection against solid objects like dust.
The second digit '5' indicates the level of protection against water ingress.
Commonly used in outdoor or industrial applications where the panel may be exposed to...
TCS and Master Trip Relay are protective devices used in electrical systems to prevent damage during faults.
TCS stands for Time Current Characteristic Relay, which operates based on the relationship between time and current to trip the circuit breaker during faults.
Master Trip Relay is a relay that receives signals from various protective relays and initiates a trip signal to disconnect the circuit in case of a fault.
B...
LSC 2A and LSC 2B are standards for lighting in commercial and industrial buildings.
LSC 2A and LSC 2B are part of the Lighting Power Density (LPD) requirements in building codes.
LSC 2A is for commercial buildings while LSC 2B is for industrial buildings.
They specify the maximum allowable power consumption for lighting per unit area in a building.
For example, LSC 2A may require a maximum LPD of 0.9 watts per square foot
REF protection is used to prevent damage to equipment from electrical faults. High impedance protection is used for sensitive equipment, while low impedance protection is used for power systems.
REF protection is used to detect ground faults and prevent damage to equipment.
High impedance protection is used for sensitive equipment that requires high accuracy and low fault currents.
Low impedance protection is used for pow...
ANSI codes are used to identify various types of protection devices in electrical systems.
ANSI code 50/51 is for instantaneous overcurrent protection
ANSI code 67 is for directional power protection
ANSI code 87 is for differential protection
ANSI code 59 is for overvoltage protection
A capacitor is an electronic component that stores and releases electrical energy in a circuit.
Capacitors consist of two conductive plates separated by an insulating material called a dielectric.
They are commonly used in electronic circuits to filter out noise, smooth voltage fluctuations, and store energy.
Capacitors are rated in farads (F) for their capacitance value.
Examples of capacitors include ceramic capacitors, ...
MCB is a miniature circuit breaker used for low currents, while MCCB is a molded case circuit breaker used for higher currents.
MCB is designed for low currents, typically up to 100A, while MCCB is designed for higher currents, typically up to 2500A.
MCB is a compact device with fixed trip settings, while MCCB is larger and has adjustable trip settings.
MCB is commonly used in residential and commercial applications, whil...
A relay is an electrically operated switch that uses an electromagnet to mechanically operate the switch contacts.
Relays are used to control high power circuits with a low power signal.
When the coil of the relay is energized, it creates a magnetic field that causes the switch contacts to close or open.
Relays are commonly used in automotive applications, industrial controls, and home appliances.
There are different types...
I applied via Recruitment Consulltant and was interviewed in May 2023. There were 3 interview rounds.
Application of technical knowledge in your previous experience
I applied via campus placement at Sri Jayachamarajendran College of Engineering (SJCE) and was interviewed in Aug 2023. There were 2 interview rounds.
Technical,verbal,and logical question
I applied via Recruitment Consulltant and was interviewed in Aug 2022. There were 3 interview rounds.
I applied via Recruitment Consulltant and was interviewed in Jan 2022. There was 1 interview round.
I would rate myself as highly proficient in AutoCAD.
I have extensive experience using AutoCAD in various design projects.
I am skilled in creating detailed 2D and 3D models using AutoCAD.
I am familiar with advanced features and tools in AutoCAD, such as parametric modeling and rendering.
I have successfully completed complex design projects using AutoCAD, meeting all requirements and deadlines.
I continuously update my kn...
based on 7 reviews
Rating in categories
Senior Engineer
81
salaries
| ₹4.4 L/yr - ₹11.6 L/yr |
Design Engineer
66
salaries
| ₹2 L/yr - ₹6.5 L/yr |
Engineer
51
salaries
| ₹2.9 L/yr - ₹7 L/yr |
Deputy Manager
48
salaries
| ₹7.5 L/yr - ₹16.5 L/yr |
Senior Design Engineer
23
salaries
| ₹5.1 L/yr - ₹10 L/yr |
Siemens
TK Elevator
Bosch
ABB