A fuse is an electrical safety device that protects electrical circuits from overloading and short circuits. Its maximum rating depends on the application.
A fuse contains a metal wire or filament that melts when the current exceeds a certain level, breaking the circuit and preventing damage to the equipment or wiring.
Fuses are rated based on their current-carrying capacity and voltage rating.
Examples of fuse ratings in...
Relays are electrically operated switches used to control circuits. There are several types of relays.
Electromechanical relays use a coil to create a magnetic field that pulls a switch to make or break a circuit.
Solid-state relays use semiconductor devices to switch the circuit on and off.
Reed relays use a magnetic field to control the switch.
Polarized relays have a specific polarity and can only be used in one directi...
Schneider Electric interview questions for designations
I applied via Job Portal and was interviewed in Aug 2021. There were 5 interview rounds.
Live sheetmetal designing using Creo/Solidworks involves real-time creation and modification of sheet metal parts.
Ability to create and modify sheet metal parts in real-time
Knowledge of sheet metal design principles and manufacturing processes
Proficiency in using Creo/Solidworks sheet metal tools
Understanding of bend allowances, K-factors, and other sheet metal parameters
Experience with designing sheet metal parts for ...
Top trending discussions
posted on 23 Sep 2024
The current unit refers to the standard unit of measurement being used in a particular context.
The current unit can vary depending on the field or industry, such as inches in construction or Celsius in weather forecasting.
It is important to clarify the current unit to ensure accurate communication and data analysis.
Examples of current units include meters for length, kilograms for weight, and seconds for time.
The resistance unit is the ohm (Ω), which measures the opposition to the flow of electric current.
The resistance unit is measured in ohms (Ω)
It represents the opposition to the flow of electric current
Resistance can be calculated using Ohm's Law: R = V/I, where R is resistance, V is voltage, and I is current
I applied via Walk-in and was interviewed in Mar 2024. There was 1 interview round.
CT current can be calculated by dividing the primary current by the turns ratio of the current transformer.
CT current = Primary current / Turns ratio
Primary current is the current flowing through the primary conductor
Turns ratio is the ratio of the number of turns in the primary winding to the number of turns in the secondary winding
Lockout is a safety procedure used to ensure that machinery or equipment is properly shut off and cannot be restarted until maintenance or servicing is completed.
Lockout involves isolating energy sources to prevent accidental startup.
Lockout devices like padlocks and tags are used to physically lock equipment.
Lockout procedures must be followed to prevent accidents and injuries.
Examples of lockout include locking out e...
IP65 for panel refers to the level of protection against dust and water ingress.
IP65 rating means the panel is dust tight and protected against water jets from any direction.
The first digit '6' indicates the level of protection against solid objects like dust.
The second digit '5' indicates the level of protection against water ingress.
Commonly used in outdoor or industrial applications where the panel may be exposed to...
TCS and Master Trip Relay are protective devices used in electrical systems to prevent damage during faults.
TCS stands for Time Current Characteristic Relay, which operates based on the relationship between time and current to trip the circuit breaker during faults.
Master Trip Relay is a relay that receives signals from various protective relays and initiates a trip signal to disconnect the circuit in case of a fault.
B...
LSC 2A and LSC 2B are standards for lighting in commercial and industrial buildings.
LSC 2A and LSC 2B are part of the Lighting Power Density (LPD) requirements in building codes.
LSC 2A is for commercial buildings while LSC 2B is for industrial buildings.
They specify the maximum allowable power consumption for lighting per unit area in a building.
For example, LSC 2A may require a maximum LPD of 0.9 watts per square foot
REF protection is used to prevent damage to equipment from electrical faults. High impedance protection is used for sensitive equipment, while low impedance protection is used for power systems.
REF protection is used to detect ground faults and prevent damage to equipment.
High impedance protection is used for sensitive equipment that requires high accuracy and low fault currents.
Low impedance protection is used for pow...
ANSI codes are used to identify various types of protection devices in electrical systems.
ANSI code 50/51 is for instantaneous overcurrent protection
ANSI code 67 is for directional power protection
ANSI code 87 is for differential protection
ANSI code 59 is for overvoltage protection
Motor selection for rotary table involves considering torque requirements, speed, size constraints, and control system compatibility.
Consider torque requirements for the rotary table based on load and acceleration/deceleration needs
Select a motor with appropriate speed capabilities to meet the desired rotation speed
Ensure the motor size fits within the constraints of the rotary table design
Check compatibility with the ...
posted on 30 May 2024
I applied via Naukri.com and was interviewed in Nov 2023. There were 4 interview rounds.
Making an animated clip from a reference video provided.
posted on 10 Feb 2025
Cad test & technical
based on 4 interviews
1 Interview rounds
based on 32 reviews
Rating in categories
Deputy Manager
1.2k
salaries
| ₹5.2 L/yr - ₹14.3 L/yr |
Senior Manager
678
salaries
| ₹9 L/yr - ₹28 L/yr |
Manager
673
salaries
| ₹5.8 L/yr - ₹22 L/yr |
Assistant Manager
324
salaries
| ₹3.8 L/yr - ₹11 L/yr |
Senior Engineer
300
salaries
| ₹3.5 L/yr - ₹12 L/yr |
Siemens
ABB
Honeywell Automation
Emerson Electric Co.