Filter interviews by
I applied via Naukri.com and was interviewed in May 2024. There was 1 interview round.
I was interviewed before Feb 2024.
Top trending discussions
posted on 24 Sep 2024
The question is likely asking about the difference between joining tables in a database.
Explain the concept of joining tables in a database
Discuss different types of joins such as inner join, outer join, and cross join
Provide examples of how joining tables can be used to retrieve data from multiple tables
posted on 23 Jun 2024
I applied via LinkedIn
posted on 2 May 2024
I applied via Approached by Company and was interviewed in Apr 2024. There was 1 interview round.
posted on 16 Apr 2024
I applied via Walk-in and was interviewed in Mar 2024. There was 1 interview round.
posted on 16 Dec 2023
I applied via LinkedIn and was interviewed in Jun 2023. There were 2 interview rounds.
The hipot test can be done on a cable multiple times depending on the specific requirements and standards.
The number of times a hipot test can be done on a cable depends on the cable's specifications and the testing requirements.
Generally, a hipot test is performed once during the manufacturing process to ensure the cable's insulation integrity.
However, additional hipot tests may be conducted during the cable's lifespa...
If battery polarity is inverse with respect to battery charger, it can lead to damage or malfunction.
Inverse polarity can cause short circuits or overheating.
It can damage the battery, charger, or both.
Reverse polarity protection circuits can prevent damage.
Always double-check the polarity before connecting the battery to the charger.
There are several types of earthing used in electrical systems.
The most common types of earthing are:
- TN-S system: Separate neutral and protective earth conductors
- TN-C system: Combined neutral and protective earth conductors
- TN-C-S system: Combination of TN-S and TN-C systems
- TT system: Separate earth electrode for each electrical installation
- IT system: No direct connection between earth and neutral
Each type of ...
I have handled various quality documents such as quality control plans, inspection reports, and non-conformance reports.
Quality control plans
Inspection reports
Non-conformance reports
Tests done on power transformers include insulation resistance, turns ratio, winding resistance, and dielectric tests.
Insulation resistance test checks the insulation quality of the transformer.
Turns ratio test measures the ratio of primary to secondary turns.
Winding resistance test determines the resistance of transformer windings.
Dielectric tests assess the dielectric strength and insulation properties of the transfo...
Hipot testing is a process used to verify the insulation integrity of busbars, breakers, cables, and transformers.
Hipot testing involves applying a high voltage to the component being tested.
The purpose is to check for any insulation breakdown or leakage current.
For busbars and cables, the test is typically performed between the conductor and the ground.
For breakers and transformers, the test is performed between diffe...
IR, WR, and CR are abbreviations used in different contexts. IR stands for Infrared, WR stands for Weather Resistant, and CR stands for Compression Ratio.
IR refers to Infrared, which is a type of electromagnetic radiation with longer wavelengths than visible light.
WR is used to indicate that a product or material is designed to withstand various weather conditions.
CR is a term commonly used in engineering and physics t...
Tap changer in a transformer is located on the high voltage winding side to regulate the voltage output.
Tap changer is typically located on the high voltage winding side of a transformer.
It is used to adjust the turns ratio and regulate the voltage output.
If the voltage output in the secondary decreases, the tap changer will be moved to a higher tap position to increase the voltage.
I applied via campus placement at Tolani Maritime Institute, Pune
General Ouestion and aptitude
posted on 5 Sep 2023
I applied via Approached by Company and was interviewed in Aug 2023. There were 2 interview rounds.
Tree lamp method is a technique used to test the insulation resistance of electrical equipment.
Tree lamp method involves connecting a high voltage source to the equipment under test and measuring the insulation resistance.
The test is performed by applying a voltage between the conductors and the earthed parts of the equipment.
The insulation resistance is calculated using Ohm's Law: R = V/I, where R is the resistance, V...
posted on 20 Apr 2024
I applied via Company Website and was interviewed in Mar 2024. There was 1 interview round.
based on 2 interviews
Interview experience
based on 39 reviews
Rating in categories
Piping Engineer
5
salaries
| ₹1.7 L/yr - ₹5 L/yr |
Account Assistant
5
salaries
| ₹1.8 L/yr - ₹2.2 L/yr |
Estimation Engineer
5
salaries
| ₹3.1 L/yr - ₹5 L/yr |
Senior Manager
5
salaries
| ₹13.5 L/yr - ₹14.5 L/yr |
Engineer
5
salaries
| ₹2.4 L/yr - ₹4.6 L/yr |
ABG Shipyard
Bharati Defence and Infrastructure
Swan Defence and Heavy Industries
Coastal Marine Construction & Engineering