Filter interviews by
I applied via Company Website and was interviewed in Aug 2024. There were 2 interview rounds.
Channel dredging given depths in meters
Regards channel dredging how to carried out
Top trending discussions
posted on 9 Aug 2023
I was interviewed in Feb 2023.
FAR stands for Floor Area Ratio, which is the ratio of a building's total floor area to the size of the piece of land on which it is built. Floor area refers to the total area of a floor in a building, carpet area is the area within the walls, and built-up area includes carpet area plus the thickness of walls.
FAR (Floor Area Ratio) is the ratio of a building's total floor area to the size of the land it is built on.
Flo...
posted on 7 May 2024
I applied via Approached by Company and was interviewed before May 2023. There was 1 interview round.
Tests to be conducted before charging of Power transformer
Insulation resistance test
Polarity and phase-relation test
Turns ratio test
Vector group test
Oil test
Functional test
Scheduled maintenance programs for TSS and PSS
TSS (Total Suspended Solids) requires regular cleaning of filters and monitoring of chemical levels
PSS (Particulate Suspended Solids) requires regular cleaning of filters and monitoring of pressure levels
Both TSS and PSS require regular calibration of instruments and replacement of worn out parts
Maintenance schedules may vary depending on the specific equipment and usage
Reg...
Charging current of transmission line varies based on the conditions - OH or UG.
Charging current is the current that flows through the capacitance of the transmission line.
In OH conditions, the charging current is higher due to the larger distance between the conductors and the ground.
In UG conditions, the charging current is lower due to the smaller distance between the conductors and the ground.
The charging current a...
Use advanced earthing techniques and equipment to accurately measure earth values in rocky areas.
Use specialized equipment like clamp-on ground resistance testers
Install additional grounding rods to improve accuracy
Consider using chemical electrodes for better contact with the ground
Ensure proper installation and maintenance of earthing system
Consult with experts in earthing and grounding for best practices
The standard of railway crossings for different voltage lines as per RDSO.
RDSO specifies different standards for railway crossings based on the voltage of the lines.
For 33 kV lines, the minimum height of the overhead equipment is 5.5 meters.
For 11 kV lines, the minimum height of the overhead equipment is 5 meters.
For 132 kV lines, the minimum height of the overhead equipment is 7 meters.
For 440 kV lines, the minimum he...
Differential potential of transformer is the voltage difference between the primary and secondary windings.
It is a measure of the transformer's ability to isolate the primary and secondary circuits.
It is important for safety and proper functioning of the transformer.
The differential potential is affected by the turns ratio and the insulation between the windings.
A high differential potential can cause arcing and damage...
SOP of RE projects involves defining project scope, identifying stakeholders, creating project plan, executing and monitoring progress.
Define project scope and objectives
Identify stakeholders and their requirements
Create project plan with timelines and milestones
Execute project plan and monitor progress
Manage risks and issues
Ensure quality control and compliance
Close out project and conduct lessons learned
Implement strict inventory management, conduct regular audits, and train employees on theft prevention and material handling.
Implement a strict inventory management system to keep track of all materials and equipment.
Conduct regular audits to identify any discrepancies or missing items.
Train employees on theft prevention techniques and proper material handling procedures.
Install security cameras and alarms to deter the...
posted on 23 Apr 2022
I applied via Walk-in and was interviewed in Dec 2021. There was 1 interview round.
posted on 17 Sep 2021
I applied via Naukri.com and was interviewed in Mar 2021. There were 3 interview rounds.
Take appropriate action against contractors not complying with specifications.
Identify the specific non-compliance issues
Communicate the non-compliance to the contractors
Request corrective actions or modifications to meet the specifications
Monitor and document the progress of corrective actions
Consider penalties or contract termination if non-compliance persists
I applied via LinkedIn and was interviewed in Nov 2021. There were 3 interview rounds.
based on 1 interview
Interview experience
based on 41 reviews
Rating in categories
Industrial Trainee
10
salaries
| ₹0.9 L/yr - ₹2.4 L/yr |
Senior Assistant
6
salaries
| ₹6 L/yr - ₹8 L/yr |
Assistant Manager
5
salaries
| ₹7.5 L/yr - ₹15 L/yr |
Joint General Manager
5
salaries
| ₹19.5 L/yr - ₹33 L/yr |
Deputy General Manager
4
salaries
| ₹22 L/yr - ₹24 L/yr |
Inland Waterways Authority of India
Mercator
Adani Ports and SEZ
Essar Ports