Filter interviews by
I applied via Referral and was interviewed in Oct 2020. There were 5 interview rounds.
There are several file extensions used in Revit, including .rvt, .rfa, .rte, .rft, .rte, .rte, .rvtl, .rvtz, .rvtc, .rvtm, .rvtlink, .rvtserver, .rvtjournal, .rvtlib, .rvtlog, .rvttmp, .rvtstate, .rvtbackup, .rvtjournal, .rvtserver, .rvtlib, .rvtlog, .rvttmp, .rvtstate, .rvtbackup
The most common file extension in Revit is .rvt, which is used for project files
.rfa is used for family files, which contain individual build...
To model an I-Beam and a set of piles, pile caps, pier and pier cap in Revit, follow these steps:
Create a new project and set the units to the desired scale.
Use the Structural Framing tool to create the I-Beam.
Use the Structural Foundation tool to create the piles, pile caps, pier, and pier cap.
Add dimensions and annotations to the model as needed.
Save the model and export it in the desired format.
Lap length is the amount of overlap between two reinforcing bars in a concrete structure.
Lap length is determined by the diameter of the bars and the strength of the concrete.
It is important to follow the lap length requirements to ensure the structural integrity of the building.
Lap length can vary depending on the type of reinforcement used and the specific design of the structure.
For example, lap length for tension b...
Reinforcement placing in a pile involves placing steel bars or cages inside a drilled hole before pouring concrete.
Reinforcement is placed in a pile to increase its strength and stability.
The size and spacing of the reinforcement bars are determined by the design requirements.
The reinforcement is usually placed in a cage or bundle and lowered into the drilled hole.
The cage or bundle is then secured in place and the con...
I applied via Company Website and was interviewed in Oct 2020. There was 1 interview round.
Top trending discussions
I applied via Recruitment Consulltant and was interviewed before Jun 2023. There were 2 interview rounds.
Single phase and three phase are two types of electrical power distribution systems.
Single phase has one live conductor and one neutral conductor, while three phase has three live conductors and one neutral conductor.
Single phase is commonly used in residential and small commercial applications, while three phase is used in industrial and large commercial applications.
Single phase power supply is suitable for low power...
R, Y, B phases are the three phases of AC power supply. They differ in their phase angle and voltage level.
R phase has a phase angle of 0 degrees and is usually connected to the red wire.
Y phase has a phase angle of 120 degrees and is usually connected to the yellow wire.
B phase has a phase angle of 240 degrees and is usually connected to the blue wire.
The voltage level of each phase is the same, but they are out of ph...
In series, voltage adds up while current remains the same. In parallel, voltage remains the same while current adds up.
In series, batteries are connected end-to-end, positive to negative. In parallel, batteries are connected positive to positive and negative to negative.
Series connection increases voltage but does not increase current. Parallel connection increases current but does not increase voltage.
Series connectio...
Periodic maintenance of batteries is crucial for their longevity and optimal performance.
Check the battery terminals for corrosion and clean them if necessary
Inspect the battery case for any cracks or damage
Ensure that the battery is securely fastened in place
Check the electrolyte level and top up with distilled water if required
Test the battery voltage and recharge if necessary
A faulty battery can be identified by checking its voltage, capacity, and physical appearance.
Check the voltage of the battery using a multimeter
Test the capacity of the battery using a battery tester
Inspect the physical appearance of the battery for any signs of damage or leakage
Check the battery terminals for corrosion or loose connections
Compare the battery's performance to its specifications
FUSE, MCB, ELCB, and RCCB are all electrical protection devices, but they differ in their functions and applications.
FUSE is a simple device that protects electrical circuits from overloading or short-circuiting by melting and breaking the circuit.
MCB (Miniature Circuit Breaker) is an automatic switch that trips and cuts off the power supply when there is an overload or short-circuit.
ELCB (Earth Leakage Circuit Breaker...
A DOL starter is a direct online motor starter that provides full voltage to the motor.
Consists of a contactor, overload relay, and start/stop buttons
The contactor connects the motor to the power supply
The overload relay protects the motor from overloading
The start/stop buttons control the on/off function of the motor
Used for small motors with low starting current
Not suitable for large motors or motors with high starti
posted on 25 Mar 2021
MOS stands for Metal Oxide Semiconductor. It is a type of transistor used in electronic devices.
MOS is a type of transistor that is commonly used in electronic devices.
It is made up of a metal gate, oxide insulator, and semiconductor material.
MOS transistors are used in digital circuits, amplifiers, and memory devices.
Examples of MOS-based devices include microprocessors, memory chips, and LCD screens.
An instrument is a device used to measure, control, or regulate physical quantities such as temperature, pressure, flow, or level.
Instruments are used in various industries such as manufacturing, chemical, and oil and gas.
Examples of instruments include thermometers, pressure gauges, flow meters, and level sensors.
Instruments can be analog or digital, and can be operated manually or automatically.
Instrument technicians...
based on 3 reviews
Rating in categories
Structural Engineer
45
salaries
| ₹5 L/yr - ₹15 L/yr |
Section Engineer
37
salaries
| ₹7.3 L/yr - ₹20 L/yr |
Structural Design Engineer
36
salaries
| ₹4.8 L/yr - ₹13.3 L/yr |
Site Engineer
26
salaries
| ₹4 L/yr - ₹11.5 L/yr |
Project Management Officer
25
salaries
| ₹5.3 L/yr - ₹10 L/yr |
AECOM
RITES
Jacobs Engineering Group
WSP