Filter interviews by
posted on 30 Dec 2023
I applied via Naukri.com and was interviewed in Nov 2023. There was 1 interview round.
A control module is a device that manages and regulates the operation of a system, while a relay module is a device that controls the flow of electrical current.
Control modules are responsible for monitoring and adjusting various parameters in a system, such as temperature, pressure, or speed.
Relay modules act as switches that open or close circuits to control the flow of electrical current.
Control modules are typicall...
The system architecture of FAS (Fire Alarm System) and BMS (Building Management System) involves the integration of various components and subsystems to ensure efficient monitoring and control of fire safety and building operations.
FAS system architecture typically includes fire detectors, control panels, notification devices, and communication interfaces.
BMS system architecture typically includes sensors, controllers,...
BOQ quantity for FAS system can be calculated by determining the required components and their quantities.
Identify the components needed for the FAS system
Determine the quantity of each component required based on project specifications
Consider factors such as system size, layout, and design requirements
Calculate the total quantity by summing up the quantities of all components
Example: If the FAS system requires 10 smo...
Orifice std refers to standard orifice sizes used in engineering. Types of taps include flange taps, corner taps, and D and D/2 taps.
Orifice std refers to standard sizes of orifices used in flow measurement
Types of taps include flange taps, corner taps, and D and D/2 taps
Flange taps are used for large pipes, corner taps for small pipes, and D and D/2 taps for general applications
Pressure gauge operating range refers to the minimum and maximum pressure values that the gauge can accurately measure.
Pressure gauge operating range is typically specified by the manufacturer.
It is important to ensure that the pressure being measured falls within the gauge's operating range to ensure accurate readings.
For example, a pressure gauge with an operating range of 0-100 psi should not be used to measure pres
Straight length requirements for orifice flow element ensure accurate measurement by allowing flow to stabilize before reaching the element.
Straight length requirements typically range from 10 to 44 pipe diameters upstream and 5 to 22 pipe diameters downstream of the orifice.
These requirements help prevent flow disturbances and ensure accurate measurement of flow rate.
For example, if the pipe diameter is 4 inches, the ...
posted on 25 May 2024
posted on 1 Apr 2022
based on 12 reviews
Rating in categories
Detailing Engineer
79
salaries
| ₹1.8 L/yr - ₹4.2 L/yr |
Senior Detailing Engineer
22
salaries
| ₹2.6 L/yr - ₹7.2 L/yr |
Senior Engineer
22
salaries
| ₹2.5 L/yr - ₹6 L/yr |
Design Engineer
20
salaries
| ₹3 L/yr - ₹8 L/yr |
Production Engineer
13
salaries
| ₹1.7 L/yr - ₹3.6 L/yr |
Tata BlueScope Steel
Jindal Steel and Power
Kirby Building Systems
Interarch Building Product