Chiller and VRF systems differ in their cooling capacity, efficiency, and cost.
Chillers are better suited for large commercial buildings with high cooling loads.
VRF systems are more efficient and cost-effective for smaller buildings or individual rooms.
Chillers use water as a cooling medium, while VRF systems use refrigerant.
Chillers require more maintenance and have a longer lifespan than VRF systems.
VRF systems offer...
posted on 23 Feb 2024
I applied via Job Portal
I applied via Approached by Company and was interviewed before Jun 2022. There were 5 interview rounds.
Sub cooling in air conditioning is the process of cooling the refrigerant below its saturation temperature to improve system efficiency.
Sub cooling increases the efficiency of the air conditioning system by ensuring the refrigerant is in a liquid state before entering the expansion valve.
It helps in preventing flash evaporation of the refrigerant, which can lead to inefficiencies in the system.
Sub cooling is typically ...
ISEER rating is calculated based on the weighted average of the cooling performance of an air conditioner under different conditions.
ISEER = (Weighted Cooling Capacity at 100% load x 0.4) + (Weighted Cooling Capacity at 75% load x 0.2) + (Weighted Cooling Capacity at 50% load x 0.4)
The higher the ISEER rating, the more energy efficient the air conditioner is.
ISEER rating helps consumers compare the energy efficiency of...
The refrigeration cycle is a thermodynamic cycle used in refrigerators and air conditioning systems to transfer heat from a low temperature to a high temperature environment.
The cycle consists of four main components: compressor, condenser, expansion valve, and evaporator.
The refrigerant enters the compressor as a low-pressure gas and leaves as a high-pressure, high-temperature gas.
The high-pressure gas then flows into...
Mainstream refrigerants used in household air conditioning include R-410A, R-22, and R-134a.
R-410A is a popular refrigerant known for its high efficiency and environmental friendliness.
R-22, although being phased out due to its ozone-depleting properties, is still commonly found in older air conditioning systems.
R-134a is commonly used in automotive air conditioning systems but can also be found in some household units
1 ton cooling concept refers to the amount of heat required to melt one ton of ice in a 24-hour period.
1 ton of cooling is equal to 12,000 BTUs per hour
It is commonly used in the HVAC industry to measure the cooling capacity of air conditioning systems
For example, a 2-ton air conditioner can remove 24,000 BTUs of heat per hour
The relationship between current, voltage, and power is described by Ohm's Law, which states that current is directly proportional to voltage and inversely proportional to resistance.
Ohm's Law states that V = I * R, where V is voltage, I is current, and R is resistance.
Power (P) is calculated using the formula P = V * I, where P is power, V is voltage, and I is current.
In a circuit with a constant resistance, an increa...
1 BTU is approximately equal to 0.29307107 watts. To convert BTU to watts, multiply by 0.29307107. To convert watts to BTU, divide by 0.29307107.
1 BTU = 0.29307107 watts
To convert BTU to watts, multiply by 0.29307107
To convert watts to BTU, divide by 0.29307107
I applied via Approached by Company and was interviewed in Apr 2022. There were 4 interview rounds.
Generic leetcode easy medium
I applied via Approached by Company and was interviewed before Sep 2022. There were 3 interview rounds.
Finance Executive
152
salaries
| ₹0 L/yr - ₹0 L/yr |
Financial Analyst
137
salaries
| ₹0 L/yr - ₹0 L/yr |
Assistant Manager
95
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Financial Analyst
78
salaries
| ₹0 L/yr - ₹0 L/yr |
Design Engineer
74
salaries
| ₹0 L/yr - ₹0 L/yr |
Schindler
KONE
Johnson Lifts
Mitsubishi Electric India