Filter interviews by
I applied via Walk-in and was interviewed in Jul 2023. There were 3 interview rounds.
Safety policy is a set of rules and guidelines implemented by an organization to ensure the safety and well-being of employees.
Safety policy outlines the organization's commitment to providing a safe work environment.
It includes procedures for identifying and mitigating hazards in the workplace.
Employees are expected to follow safety policies to prevent accidents and injuries.
Regular training and communication are esse...
There are several different types of hazards, including physical, chemical, biological, ergonomic, and psychosocial hazards.
Physical hazards include noise, vibration, radiation, and temperature extremes.
Chemical hazards involve exposure to harmful substances such as gases, liquids, or dusts.
Biological hazards come from exposure to viruses, bacteria, fungi, and other living organisms.
Ergonomic hazards result from poor w...
Incidents refer to unexpected events that cause harm, damage, or disruption to people, property, or the environment.
Incidents can include accidents, injuries, spills, fires, and near misses.
They can occur in the workplace, at home, on the road, or in public spaces.
Incidents should be reported, investigated, and analyzed to prevent future occurrences.
Effective incident management involves identifying root causes, implem...
A crane is a type of machine used to lift and move heavy objects, while Le is likely a typo or abbreviation that needs clarification.
Cranes are commonly used in construction and manufacturing industries to lift and move heavy materials.
There are different types of cranes such as tower cranes, mobile cranes, and overhead cranes.
Cranes require skilled operators to ensure safety and efficiency in their operation.
Le could ...
Precautions during scaffold erection include proper training, inspection of equipment, securing the scaffold, and following safety guidelines.
Ensure workers are properly trained on scaffold erection and safety procedures
Inspect scaffold components for damage or defects before use
Secure the scaffold to prevent tipping or collapse
Follow safety guidelines such as using guardrails and fall protection systems
Regularly inspe...
Top trending discussions
Procedures for LOTO and W@H activities are essential for EHS Officer role.
Develop written procedures for each activity
Ensure procedures are communicated to all employees involved
Train employees on the procedures
Conduct regular audits to ensure compliance
Update procedures as needed based on feedback and incidents
Examples: Lockout/Tagout procedures, Working at Heights procedures
posted on 8 Dec 2024
I applied via Walk-in and was interviewed in Jun 2024. There were 3 interview rounds.
QMS is adopted to ensure consistent quality, meet customer requirements, and improve processes.
Ensures consistent quality of products or services
Helps meet customer requirements and expectations
Improves processes and efficiency
Reduces risks and errors
Enhances customer satisfaction
Provides a framework for continuous improvement
Design mix procedure involves determining the proportions of materials to create a concrete mix with desired properties.
Identify the required strength and durability of the concrete
Select suitable materials such as cement, aggregates, and water
Calculate the proportions of each material based on mix design methods
Test the mix to ensure it meets specifications
Adjust the mix if necessary to achieve desired properties
A work permit system is a formal written system used to control high-risk work activities to ensure safety of workers and the workplace.
Work permit systems outline the procedures and requirements for carrying out specific high-risk tasks.
They are used to assess risks, implement controls, and communicate safety measures to workers.
Examples include hot work permits for welding, confined space entry permits, and electrica...
Confined space is an area that is not designed for continuous occupancy, has limited entry and exit points, and may have hazardous conditions.
Confined spaces are typically small and enclosed, making it difficult to enter and exit.
These spaces may have poor ventilation, limited lighting, or contain hazardous substances.
Examples of confined spaces include storage tanks, silos, tunnels, and sewers.
Oxygen level in confined spaces should be monitored to ensure safety of workers.
Oxygen levels in confined spaces should be maintained between 19.5% and 23.5%.
Low oxygen levels can lead to dizziness, confusion, and even loss of consciousness.
High oxygen levels can increase the risk of fire and explosion.
Monitoring equipment such as oxygen meters should be used to regularly check oxygen levels in confined spaces.
posted on 12 Jun 2024
I applied via Recruitment Consulltant and was interviewed in May 2024. There was 1 interview round.
ITP stands for Inspection and Test Plan, a document outlining the procedures and criteria for quality control in a project.
Define the scope and objectives of the project
Identify the key activities and deliverables
Specify the inspection and testing requirements
Outline the acceptance criteria
Assign responsibilities and timelines
Review and approve the ITP before implementation
Checklist can be made by identifying key tasks, setting priorities, creating categories, and including necessary details.
Identify key tasks that need to be completed
Set priorities for each task
Create categories to organize tasks
Include necessary details such as deadlines, responsible parties, and resources needed
I applied via Company Website and was interviewed in Mar 2023. There were 3 interview rounds.
Normal introduction and interview
There are various types of electrical motors including AC motors, DC motors, synchronous motors, and induction motors.
AC motors: commonly used in household appliances and industrial applications
DC motors: used in applications where speed control is important, such as in electric vehicles
Synchronous motors: used in applications where precise speed control is required, such as in clocks and timers
Induction motors: widely...
Protection of transformer involves measures to prevent damage from overcurrent, overvoltage, and overheating.
Use overcurrent protection devices such as fuses and circuit breakers to prevent damage from excessive current flow.
Install overvoltage protection devices like surge arresters to safeguard against voltage spikes.
Implement temperature monitoring systems to prevent overheating, such as thermal sensors and cooling ...
DOL starter stands for Direct-On-Line starter, used to start motors by directly connecting them to the power supply.
DOL starter is the simplest and most common type of motor starter.
It directly connects the motor to the power supply without any intermediate starting method.
It provides full voltage to the motor during starting, which can cause high inrush current.
DOL starters are suitable for small to medium-sized motor...
APFC PANEL stands for Automatic Power Factor Correction Panel, used to maintain power factor in electrical systems.
APFC PANEL automatically monitors and corrects the power factor of electrical systems.
It helps in reducing electricity bills by maintaining a high power factor.
APFC PANELs are commonly used in industries and commercial buildings.
They consist of capacitors that are switched on and off based on the load requ...
posted on 28 Dec 2022
I applied via Naukri.com and was interviewed in Jun 2022. There were 2 interview rounds.
ATS stands for Automatic Transfer Switch. It is used to transfer power supply between two sources. Transformer and motor maintenance procedures and protection methods are essential for their efficient operation. SAP is a software used for enterprise resource planning.
ATS is used to automatically switch power supply between two sources, ensuring uninterrupted power supply.
Transformer maintenance involves regular inspect...
HT motor rating is the maximum power it can handle and FLC is the current it draws at full load.
HT motor rating is expressed in kilowatts (kW) or megawatts (MW).
FLC of HT motor is the full load current it draws at rated voltage and frequency.
FLC is expressed in amperes (A) and varies depending on the motor's power rating and efficiency.
For example, a 1 MW HT motor may have a FLC of 1000 A at 11 kV.
The rating and FLC of...
Plant EHT system and single line diagram of plants.
EHT system refers to Extra High Tension system used in power plants
Single line diagram shows the electrical connections between different components
It is important to have a clear and accurate diagram for safety and maintenance purposes
posted on 27 Jun 2022
I applied via Recruitment Consulltant
Electrical panels can be used by various types of contractors.
Electrical contractors are the most common type of contractors who use electrical panels.
General contractors may also use electrical panels for specific projects.
HVAC contractors may require electrical panels for their heating and cooling systems.
Plumbing contractors may need electrical panels for water heaters or pumps.
Fire protection contractors may use el...
Various types of MCBs are used in the panel.
Type B MCB for general purpose circuits
Type C MCB for circuits with inductive loads
Type D MCB for circuits with high inrush currents
Type K MCB for circuits with high inrush currents and motors
Type Z MCB for circuits with DC components
Type F MCB for circuits with sensitive equipment
Type G MCB for circuits with surge protection
Type L MCB for lighting circuits
AC current changes direction periodically while DC current flows in one direction only.
AC current is used in household appliances while DC current is used in batteries and electronic devices.
AC current can be easily transformed into different voltages using a transformer while DC current cannot.
AC current is more dangerous to humans than DC current because it can cause muscle contractions.
DC current is more efficient f...
Voltage is the measure of electric potential difference between two points in a circuit.
Voltage is measured in volts (V).
It is the force that drives electric current through a circuit.
Voltage can be positive or negative depending on the direction of the current flow.
A battery provides a voltage difference between its terminals to power a circuit.
Voltage drop occurs when there is a decrease in voltage along a circuit du
The question is unclear. Please provide more context.
Please provide more information about the fault.
Are you asking about fault-finding techniques or the number of people required to find a fault?
Without more context, it is difficult to provide a specific answer.
Transformer safety parts include fuses, circuit breakers, and grounding systems.
Fuses protect against overcurrent and short circuits.
Circuit breakers protect against overloads and faults.
Grounding systems prevent electrical shock and protect equipment.
Other safety parts may include temperature sensors and pressure relief devices.
Capacitors are used to store and release electrical energy in circuits.
Capacitors can filter out noise and stabilize voltage in power supplies.
They can also be used in timing circuits and oscillators.
Capacitors are commonly used in audio equipment to filter out unwanted frequencies.
They can also be used in electric motors to improve power factor and efficiency.
Capacitors are essential components in electronic devices a
A sun t relay is a type of time-delay relay used in electrical systems.
It is used to control the operation of a circuit based on a time delay.
It is commonly used in lighting systems to delay turning on or off.
It can also be used in motor control circuits to prevent damage from sudden power surges.
The delay time can be adjusted to suit the specific needs of the circuit.
It works by using a small current to charge a capac...
Under voltage can cause major electrical problems.
Under voltage can cause equipment damage and failure.
It can also lead to power outages and disruptions.
Proper monitoring and maintenance can prevent under voltage issues.
Examples of under voltage problems include brownouts and voltage sags.
based on 1 interview
Interview experience
based on 1 review
Rating in categories
Engineer
901
salaries
| ₹2.2 L/yr - ₹7 L/yr |
Senior Engineer
850
salaries
| ₹3.2 L/yr - ₹11.5 L/yr |
Associate Manager
493
salaries
| ₹4.8 L/yr - ₹15.5 L/yr |
Mechanical Engineer
407
salaries
| ₹2.1 L/yr - ₹9 L/yr |
Civil Engineer
354
salaries
| ₹2.2 L/yr - ₹7.5 L/yr |
Larsen & Toubro Limited
Tata Projects
GMR Group
Hindustan Construction Company