Filter interviews by
I applied via Campus Placement and was interviewed before Mar 2022. There were 4 interview rounds.
General Aptitude test of 50 questions, need to clear in 1 hour
Top trending discussions
posted on 19 Mar 2015
I have the necessary skills, experience, and passion to excel in this role.
I have a strong background in design engineering with a proven track record of success.
I am highly skilled in using various design software and tools.
I am a quick learner and can adapt to new technologies and processes easily.
I am a team player and can work collaboratively with others to achieve common goals.
I am passionate about design engineer...
posted on 8 Jan 2015
Discussion on soil mechanics starting from modulus of elasticity to liquifaction
Modulus of elasticity is a measure of soil stiffness
Soil strength is important in determining its ability to withstand loads
Liquifaction occurs when soil loses strength and behaves like a liquid
Factors affecting soil strength include soil type, moisture content, and stress history
Liquifaction can lead to soil failure and damage to structure
posted on 10 Sep 2015
I applied via PLACEMENT
posted on 10 Sep 2017
I was interviewed before Sep 2016.
posted on 12 May 2018
posted on 18 Nov 2020
Android architecture stack is a set of layers that make up the Android operating system.
The stack includes four main layers: Linux kernel, native libraries, Android runtime, and application framework.
The Linux kernel provides low-level system functionality.
Native libraries are written in C or C++ and provide access to hardware-specific features.
The Android runtime includes the Dalvik virtual machine and core libraries.
...
AIDL stands for Android Interface Definition Language, used for inter-process communication in Android.
AIDL is used to define the interface between client and service in Android.
It allows communication between different processes in Android.
AIDL is used to pass complex data types between processes.
AIDL is similar to Remote Procedure Call (RPC) in other programming languages.
Example: AIDL is used in Android to implement...
Hash set and hash map are data structures used to store key-value pairs for efficient retrieval.
Hash set stores unique values without any specific order.
Hash map stores key-value pairs and allows fast retrieval of values based on keys.
Both use hashing to map keys to their corresponding values.
In Java, HashSet and HashMap are implementations of these data structures.
posted on 4 Nov 2021
I applied via Naukri.com and was interviewed in May 2021. There were 3 interview rounds.
I applied via Walk-in and was interviewed in Mar 2024. There was 1 interview round.
CT current can be calculated by dividing the primary current by the turns ratio of the current transformer.
CT current = Primary current / Turns ratio
Primary current is the current flowing through the primary conductor
Turns ratio is the ratio of the number of turns in the primary winding to the number of turns in the secondary winding
Lockout is a safety procedure used to ensure that machinery or equipment is properly shut off and cannot be restarted until maintenance or servicing is completed.
Lockout involves isolating energy sources to prevent accidental startup.
Lockout devices like padlocks and tags are used to physically lock equipment.
Lockout procedures must be followed to prevent accidents and injuries.
Examples of lockout include locking out e...
IP65 for panel refers to the level of protection against dust and water ingress.
IP65 rating means the panel is dust tight and protected against water jets from any direction.
The first digit '6' indicates the level of protection against solid objects like dust.
The second digit '5' indicates the level of protection against water ingress.
Commonly used in outdoor or industrial applications where the panel may be exposed to...
TCS and Master Trip Relay are protective devices used in electrical systems to prevent damage during faults.
TCS stands for Time Current Characteristic Relay, which operates based on the relationship between time and current to trip the circuit breaker during faults.
Master Trip Relay is a relay that receives signals from various protective relays and initiates a trip signal to disconnect the circuit in case of a fault.
B...
LSC 2A and LSC 2B are standards for lighting in commercial and industrial buildings.
LSC 2A and LSC 2B are part of the Lighting Power Density (LPD) requirements in building codes.
LSC 2A is for commercial buildings while LSC 2B is for industrial buildings.
They specify the maximum allowable power consumption for lighting per unit area in a building.
For example, LSC 2A may require a maximum LPD of 0.9 watts per square foot
REF protection is used to prevent damage to equipment from electrical faults. High impedance protection is used for sensitive equipment, while low impedance protection is used for power systems.
REF protection is used to detect ground faults and prevent damage to equipment.
High impedance protection is used for sensitive equipment that requires high accuracy and low fault currents.
Low impedance protection is used for pow...
ANSI codes are used to identify various types of protection devices in electrical systems.
ANSI code 50/51 is for instantaneous overcurrent protection
ANSI code 67 is for directional power protection
ANSI code 87 is for differential protection
ANSI code 59 is for overvoltage protection
based on 1 interview
Interview experience
based on 5 reviews
Rating in categories
Assistant Manager
418
salaries
| ₹0 L/yr - ₹0 L/yr |
Deputy Manager
295
salaries
| ₹0 L/yr - ₹0 L/yr |
Associate Manager
236
salaries
| ₹0 L/yr - ₹0 L/yr |
Manager
215
salaries
| ₹0 L/yr - ₹0 L/yr |
Business Manager
116
salaries
| ₹0 L/yr - ₹0 L/yr |
CG Power and Industrial Solutions
Thermax Limited
BHEL
Larsen & Toubro Limited