The pH value of bentonite typically ranges from 8 to 10.
Bentonite is a clay material commonly used in construction and engineering projects.
The pH value of bentonite can vary depending on its source and composition.
A pH value of 7 is considered neutral, so bentonite is slightly alkaline.
The pH value of bentonite is important in determining its suitability for various applications.
FE500 is a grade of steel used in construction, indicating its yield strength in megapascals.
FE500 is a designation for a type of steel reinforcement used in construction
The 'FE' stands for 'iron', while '500' indicates the minimum yield strength in megapascals
FE500 steel is commonly used in reinforced concrete structures for its high strength and durability
I applied via campus placement at Birla Institute of Technology and Science (BITS), Pilani and was interviewed in Jul 2024. There were 3 interview rounds.
Social media connecting people
Sfd and bmd diagrams show the variation of shear force and bending moment along the length of a structural member.
SFD (Shear Force Diagram) shows the variation of shear force along the length of a beam or structural member.
BMD (Bending Moment Diagram) shows the variation of bending moment along the length of a beam or structural member.
SFD and BMD are essential for analyzing the internal forces and moments in a structu...
I am a structural engineer with 5 years of experience in designing and analyzing buildings and bridges.
Graduated with a degree in Civil Engineering
Worked on various projects including high-rise buildings and pedestrian bridges
Proficient in software such as AutoCAD and SAP2000
I am open to job locations that offer opportunities for growth and development.
I am willing to relocate for the right job opportunity
I prefer job locations with good transportation options
I am open to both urban and rural locations depending on the job requirements
posted on 3 Jan 2025
I applied via LinkedIn and was interviewed in Feb 2024. There were 2 interview rounds.
Static analysis deals with loads that do not change over time, while dynamic analysis considers loads that vary with time.
Static analysis is used to determine the effects of loads that do not change over time, such as dead loads and live loads.
Dynamic analysis considers loads that vary with time, such as wind loads, seismic loads, and vibrations.
Static analysis is simpler and less computationally intensive compared to ...
Spectral fatigue analysis is performed by calculating the stress response of a structure to dynamic loads over a range of frequencies.
Determine the dynamic loads acting on the structure
Calculate the stress response of the structure using spectral methods
Analyze the stress response at different frequencies to assess fatigue damage
Consider factors such as material properties, load history, and environmental conditions
Use...
I prioritize transparency, disclose the conflict, and recuse myself if necessary.
Prioritize transparency and disclose the conflict to all parties involved
Evaluate the situation and determine if recusal is necessary
Seek guidance from a supervisor or ethics committee if unsure how to proceed
My notice period is currently one month.
Notice period is one month
I am required to give one month notice before leaving my current position
I can start a new position after one month
I applied via Walk-in and was interviewed in Feb 2024. There was 1 interview round.
IS 2911 is the Indian Standard code for design and construction of pile foundations.
IS 2911 is the code for design and construction of pile foundations in India.
It covers various types of piles including driven piles, bored cast-in-situ piles, etc.
The code provides guidelines for the design, materials, construction, and testing of piles.
It ensures the safety and stability of structures supported by piles.
Example: IS 29...
The density of bentonite during piling is typically around 1.0 to 1.2 g/cm^3.
The density of bentonite can vary depending on the specific type and concentration used.
Higher density bentonite is often preferred for better support during piling operations.
Typical range of density for bentonite during piling is 1.0 to 1.2 g/cm^3.
Yes, I have extensive experience with basements and below ground structures.
I have designed and analyzed numerous basements for residential and commercial buildings.
I am familiar with waterproofing techniques and soil mechanics related to below ground structures.
I have experience with retaining walls, foundations, and underground parking structures.
I have worked on projects involving deep excavations and shoring system...
based on 2 interviews
Interview experience
based on 7 reviews
Rating in categories
Design Engineer
271
salaries
| ₹4.5 L/yr - ₹18 L/yr |
Senior Design Engineer
151
salaries
| ₹7.5 L/yr - ₹26 L/yr |
Piping Designer
100
salaries
| ₹3.4 L/yr - ₹15 L/yr |
Piping Design Engineer
99
salaries
| ₹4.7 L/yr - ₹15 L/yr |
Senior Engineer
73
salaries
| ₹9 L/yr - ₹21 L/yr |
AECOM
Bechtel
Fluor Corporation
Worley