Q1. 1 ton steel work how much quantity of binding wire required?
The quantity of binding wire required for 1 ton of steel work depends on various factors such as the type of binding wire used, the thickness of the steel bars, and the binding technique.
The type of binding wire used can vary, such as galvanized or black annealed wire.
The thickness of the steel bars also affects the quantity of binding wire required.
The binding technique, whether it is single or double binding, will determine the amount of wire needed.
To determine the exact q...read more
Q2. What is the pressure of CPVC pipe when testing the water test?
The pressure of CPVC pipe during water testing varies depending on the specific application and industry standards.
The pressure of CPVC pipe during water testing is typically measured in pounds per square inch (psi).
The specific pressure requirements may vary based on the intended use of the CPVC pipe, such as residential plumbing or industrial applications.
Industry standards, such as ASTM D1785 for CPVC pipes, provide guidelines for the pressure ratings of CPVC pipes.
For exa...read more
Q3. Which brand of CP sanitary used in your current project?
The brand of CP sanitary used in my current project is XYZ.
The brand XYZ is known for its high-quality and durable CP sanitary products.
We chose XYZ brand for its wide range of options and competitive pricing.
The CP sanitary products from XYZ have been performing well in our project.
We have received positive feedback from the users regarding the XYZ brand.
Q4. Cost of material and labour for Door frame with the size of 3"*4"*7' ?
The cost of material and labor for a door frame with the size of 3"*4"*7' depends on various factors.
The cost of material will depend on the type of wood or material used for the door frame.
The cost of labor will depend on the hourly rate of the workers and the time required to complete the installation.
Additional costs may include transportation, tools, and any customization or finishing required.
To provide an accurate cost estimate, specific prices for materials and labor r...read more
Q5. How we can design busbar for increased fault level but same current rating?
To design busbar for increased fault level but same current rating, increase the cross-sectional area of the busbar.
Increase the thickness of the busbar
Increase the width of the busbar
Use materials with higher conductivity
Use busbar supports with higher short-circuit strength
Consider the temperature rise of the busbar
Perform a fault level calculation to determine the required cross-sectional area
Q6. Should we continue concreting of foundation the next day, if there is one day of continuous rainfall?
No, it is not advisable to continue concreting of foundation the next day after one day of continuous rainfall.
Continuous rainfall can saturate the soil, making it unstable for concreting.
Rainwater can mix with the concrete, affecting its strength and durability.
The presence of water can lead to the formation of voids and cracks in the foundation.
It is important to ensure that the foundation is dry and stable before proceeding with concreting.
Delaying the concreting process b...read more
Q7. What will be the bending radius for different HT cables?
The bending radius for HT cables varies depending on the cable type and size.
The bending radius for XLPE cables is typically 12 times the cable diameter.
For PILC cables, the bending radius is usually 20 times the cable diameter.
The bending radius for EPR cables is generally 10 times the cable diameter.
It is important to follow the manufacturer's recommendations for bending radius to avoid damaging the cable.
Bending radius can also be affected by factors such as temperature an...read more
Q8. What is the slum rate for column concrete
The slum rate for column concrete is not a standard term in construction. Please provide more context.
Slump test is used to measure the consistency of concrete.
The slump test measures the vertical settlement of the concrete after the slump cone is removed.
The slump test is not used to determine the rate of concrete for columns.
The rate of concrete for columns depends on the design specifications and the construction schedule.
Q9. Working and maintenance activities regarding DG set and hydel equipment
Maintenance activities for DG set and hydel equipment involve regular inspections, servicing, and repairs to ensure optimal performance and longevity.
Regularly inspecting and testing the DG set and hydel equipment for any signs of wear or damage
Performing routine servicing such as oil changes, filter replacements, and lubrication
Conducting preventive maintenance to avoid unexpected breakdowns
Addressing any issues or malfunctions promptly to prevent further damage
Keeping detai...read more
Q10. Currently working location
I am currently working at XYZ Company as an Assistant Manager.
Currently working at XYZ Company
Position: Assistant Manager
Q11. What's opc prefer for mix design
OPC 43 grade cement is commonly preferred for mix design in construction sites.
OPC 43 grade cement has a higher compressive strength compared to OPC 33 grade cement.
It is suitable for construction of buildings, bridges, and other structures.
OPC 43 grade cement is cost-effective and easily available in the market.
It is important to consider the specific requirements of the project before finalizing the mix design.
Q12. What's explosive vent for air cooled transformer
An explosive vent is a safety device installed on air-cooled transformers to prevent explosions.
It is designed to release pressure buildup inside the transformer in case of a fault or malfunction.
The vent is typically made of a thin metal membrane that ruptures when pressure exceeds a certain level.
This allows the hot gases and oil to escape, preventing the transformer from exploding.
Explosive vents are required by industry standards and regulations to ensure the safety of pe...read more
Q13. What do you mean by quality control
Quality control refers to the process of ensuring that products or services meet the desired level of quality.
Quality control involves inspecting and testing products or services to ensure they meet the required standards.
It also involves identifying and correcting any defects or issues that may arise during the production process.
Quality control is important in construction to ensure that buildings and structures are safe and meet the necessary regulations.
Examples of qualit...read more
Q14. What is Is code for opc 33/43/53
IS code for OPC 33/43/53 is IS 269:2015
IS 269:2015 is the Indian Standard code for OPC 33/43/53
This code specifies the requirements and methods of sampling and testing for ordinary Portland cement
OPC 33/43/53 refers to the compressive strength of the cement in megapascals (MPa)
OPC 33 has a compressive strength of 33 MPa, OPC 43 has a compressive strength of 43 MPa, and OPC 53 has a compressive strength of 53 MPa
Q15. What is the stagnant hight of DG
The stagnant height of DG refers to the maximum height at which a diesel generator can operate without overheating or malfunctioning.
Stagnant height of DG is determined by factors such as cooling system efficiency, ambient temperature, and load capacity.
For example, a diesel generator may have a stagnant height of 1000 meters, meaning it can operate effectively up to that altitude.
Regular maintenance and monitoring of the cooling system are essential to ensure the DG operates...read more
Q16. How to manage store and out side material staging
To manage store and outside material staging, organize inventory, maintain clear labeling, implement FIFO system, and regularly inspect and update stock levels.
Organize inventory in a systematic manner to easily locate items
Maintain clear labeling on shelves, bins, and containers for quick identification
Implement FIFO (First In, First Out) system to ensure older stock is used first
Regularly inspect and update stock levels to avoid overstocking or stockouts
Q17. What is the mix design?
Mix design is the process of determining the proportions of cement, water, aggregates, and admixtures to produce a concrete mix with desired properties.
Mix design is crucial for achieving the desired strength, workability, and durability of concrete.
It involves selecting the appropriate materials and determining their proportions based on the desired properties of the concrete.
Factors such as the type of cement, aggregate gradation, water-cement ratio, and admixtures are cons...read more
Q18. What's ACB and how does it trip
ACB stands for Air Circuit Breaker. It trips when the current flowing through it exceeds its rated capacity.
ACB is a type of circuit breaker that is used to protect electrical circuits from overloads, short circuits, and other faults.
It works by interrupting the flow of current when it exceeds the rated capacity of the breaker.
ACBs are commonly used in industrial and commercial settings, where large amounts of power are required.
Examples of ACB manufacturers include Siemens, ...read more
Q19. 3. What type of bridges drawing you have done?
I have experience in drawing various types of bridges including beam, truss, arch, suspension, and cable-stayed bridges.
Beam bridges - simple and economical design with horizontal beams supported by piers or abutments
Truss bridges - composed of interconnected triangles for added strength and stability
Arch bridges - curved design that distributes weight evenly to supports at each end
Suspension bridges - main cables anchored to towers and suspender cables supporting the deck
Cab...read more
Q20. How much coverage does sprinkler have
The coverage of sprinklers depends on the type of sprinkler system installed and the size of the area to be covered.
Sprinkler coverage can range from a few feet to over 100 feet depending on the system.
The size and shape of the area to be covered also affects the sprinkler coverage.
Different types of sprinklers have different coverage patterns, such as circular, rectangular, or square.
Sprinkler coverage can also be affected by obstacles or obstructions in the area.
It is impor...read more
Q21. What is PRV and what are different types
PRV stands for Pressure Relief Valve. It is a safety device used to protect equipment and systems from overpressure.
PRVs are used in various industries such as oil and gas, chemical, and power generation.
There are different types of PRVs such as spring-loaded, pilot-operated, and bellows.
Spring-loaded PRVs are the most common type and operate by using a spring to keep the valve closed until the pressure exceeds a set limit.
Pilot-operated PRVs use a smaller valve to control th...read more
Q22. Shuttering column up to FFL how much cover required
The cover required for shuttering column up to FFL depends on the type of concrete being used and the environmental conditions.
Cover required for shuttering column up to FFL typically ranges from 25mm to 50mm.
Factors such as type of concrete mix, exposure conditions, and structural requirements can influence the required cover.
For example, in harsh environmental conditions or high-strength concrete, a higher cover may be needed for protection.
Consult relevant codes and standa...read more
Q23. What are Turbines and its types?
Turbines are machines that convert fluid energy into mechanical energy. There are four main types of turbines.
Turbines are used in power generation, aviation, and marine propulsion.
The four main types of turbines are steam, gas, hydro, and wind turbines.
Steam turbines are used in power plants to generate electricity.
Gas turbines are used in aviation and power generation.
Hydro turbines are used in hydroelectric power plants.
Wind turbines are used to generate electricity from w...read more
Q24. Basic make & material specifications for HVAC, FF & PHE
HVAC - Heating, Ventilation, and Air Conditioning systems; FF - Fire Fighting systems; PHE - Plumbing and Heating systems
HVAC systems are typically made of metal components such as ductwork, fans, and coils
FF systems include materials like pipes, valves, pumps, and fire extinguishers
PHE systems consist of pipes, fittings, pumps, and heat exchangers
Common materials used in these systems include steel, copper, PVC, and aluminum
Q25. What is Hazard, Risk and Control Measure
Hazard is a potential source of harm, risk is the likelihood of harm occurring, and control measures are actions taken to reduce or eliminate the risk.
Hazard: Any potential source of harm or adverse health effect.
Risk: The likelihood of harm occurring from exposure to a hazard.
Control Measure: Actions taken to reduce or eliminate the risk associated with a hazard.
Example: Hazard - Chemical exposure, Risk - Inhalation of toxic fumes, Control Measure - Providing proper ventilat...read more
Q26. Determine the breakbale point of participants regarding knowledge.
The breakable point of participants' knowledge can be determined through assessment and evaluation.
Assessment and evaluation can be done through tests, quizzes, and exams.
The breakable point can vary depending on the complexity of the subject matter.
It is important to consider the participants' background and experience.
The breakable point can also be influenced by the learning environment and teaching methods.
Regular feedback and monitoring can help determine the breakable p...read more
Q27. What is Safety Management System
Safety Management System is a systematic approach to managing safety, including policies, procedures, and processes.
SMS involves identifying hazards, assessing risks, and implementing controls to mitigate risks.
It includes setting safety goals, monitoring performance, and continuously improving safety practices.
SMS helps organizations comply with regulations, reduce incidents, and create a safer work environment.
Examples of SMS tools include incident reporting systems, safety...read more
Q28. Foundation footing how much cover required
Foundation footing requires a minimum cover of 50mm to 75mm for reinforcement protection.
Minimum cover of 50mm to 75mm is required for foundation footing to protect the reinforcement from corrosion and provide adequate strength.
The cover requirement may vary based on the type of soil, environmental conditions, and structural design.
Proper cover ensures durability and stability of the foundation.
In some cases, additional cover may be needed for specific project requirements or...read more
Q29. What you have done in hvac system?
I have experience in maintaining and troubleshooting HVAC systems.
Performed regular maintenance checks on HVAC equipment
Identified and repaired faulty components in HVAC systems
Implemented energy-saving measures to improve efficiency
Collaborated with HVAC technicians to resolve complex issues
Q30. What is the nominal size of brick
The nominal size of a brick is the size specified by the manufacturer for identification and classification purposes.
The nominal size of a brick is typically larger than its actual size to account for mortar joints.
Common nominal sizes for bricks include 4 inches by 8 inches by 2 1/4 inches and 3 5/8 inches by 2 1/4 inches by 8 inches.
It is important to consider the nominal size when planning and designing brickwork projects.
Q31. What are the admixture of concrete
Admixtures are added to concrete to alter its properties or enhance its performance.
Admixtures can improve workability, durability, strength, and set time of concrete
Types of admixtures include water reducers, accelerators, retarders, air-entraining agents, and superplasticizers
Example: Adding a water reducer admixture can increase the workability of concrete without compromising strength
Q32. CTC in current employer
I am currently earning a CTC of $60,000 per year in my current employer.
My current CTC is $60,000 per year
I have been receiving this CTC for the past 2 years
I am open to negotiation for a higher CTC in a new role
Q33. Safety measures taken while executing civil works
Safety measures are crucial during civil works to prevent accidents and injuries.
Conducting regular safety meetings and training sessions for workers
Providing personal protective equipment (PPE) such as hard hats, safety glasses, and gloves
Ensuring proper use of equipment and machinery
Implementing fall protection measures such as guardrails and safety harnesses
Maintaining a clean and organized work area to prevent tripping hazards
Having a designated safety officer on site to ...read more
Q34. Why is plumber important for building
Plumbers are important for building as they ensure proper installation and maintenance of plumbing systems.
Plumbers ensure proper installation of pipes, fixtures, and appliances for water supply and drainage.
They help prevent water damage and leaks by maintaining and repairing plumbing systems.
Plumbers play a crucial role in ensuring buildings meet plumbing codes and regulations.
They can also help improve energy efficiency by installing water-saving fixtures.
In emergency situ...read more
Q35. What is Fault Tree Analysis
Fault Tree Analysis is a systematic, deductive method used to identify the root causes of a system failure.
It starts with identifying the top event, which is the system failure.
Then, it breaks down the top event into intermediate events and basic events using logic gates.
Basic events are the lowest level events that directly contribute to the top event.
By analyzing the relationships between events, potential causes of the system failure can be identified.
It helps in understan...read more
Q36. Makes of equipments & IS codes
Various makes of equipments are available in the market, each with their own unique features and specifications. IS codes refer to Indian Standards codes that ensure quality and safety of products.
Different makes of equipments include brands like Samsung, LG, Sony, etc.
IS codes are Indian Standards codes that ensure quality and safety of products in India.
For example, IS 12345 may refer to a specific standard for a particular type of equipment.
Q37. Different make of breakers
There are various makes of breakers available in the market.
Different makes of breakers have different features and specifications.
Some popular brands include Siemens, Schneider Electric, ABB, and Eaton.
The choice of breaker depends on the application and the specific requirements.
It is important to select the right breaker to ensure safety and reliability of the electrical system.
Q38. Which softwares do you know?
I am familiar with various softwares including CMMS, CAD, and Microsoft Office Suite.
CMMS (Computerized Maintenance Management System)
CAD (Computer-Aided Design)
Microsoft Office Suite
Q39. ERP SAP work Experience
I have 3 years of experience working with ERP SAP in inventory management and data entry.
Managed inventory levels using SAP system
Entered data accurately and efficiently into SAP database
Generated reports on inventory status and trends
Collaborated with other departments to ensure accurate inventory records
Q40. Draw a SFD & BMD for fixed end beam
SFD & BMD for fixed end beam
SFD shows the variation of shear force along the length of the beam
BMD shows the variation of bending moment along the length of the beam
At fixed end, SFD starts with a downward force and BMD starts with a positive moment
SFD and BMD diagrams can be drawn using equations of equilibrium and integration
Q41. What is store process
Q42. proper update store data
Properly updating store data involves regular inventory checks, accurate recording of incoming and outgoing items, and utilizing a reliable database system.
Conduct regular inventory checks to ensure accuracy
Record incoming and outgoing items promptly and accurately
Utilize a reliable database system to store and update data
Train staff on proper data entry procedures to maintain consistency
Implement barcode scanning or RFID technology for efficient tracking
Q43. You know about spare tmt bar machine
Q44. Favourite subject
My favourite subject is Mathematics.
I enjoy solving complex problems and equations.
I find it fascinating how mathematical concepts can be applied in various fields.
I appreciate the logical and analytical thinking required in Mathematics.
I have excelled in Mathematics throughout my academic career.
I have also participated in Mathematics Olympiads and competitions.
Q45. M25 grade concrete strength
M25 grade concrete has a compressive strength of 25 megapascals after 28 days of curing.
M25 grade concrete is a mix of 1 part cement, 1 part fine aggregates, and 2 parts coarse aggregates.
The compressive strength of M25 grade concrete is typically achieved after 28 days of curing.
The strength of M25 grade concrete is 25 megapascals, which is suitable for structural applications.
Q46. What is plumber
A plumber is a skilled tradesperson who installs and repairs pipes and plumbing fixtures.
Plumbers work with various materials such as copper, PVC, and PEX piping.
They install and repair water supply lines, drainage systems, and fixtures like sinks and toilets.
Plumbers may also work on gas lines, heating systems, and water heaters.
They use tools such as wrenches, pipe cutters, and soldering equipment.
Plumbers often work in residential, commercial, and industrial settings.
Q47. physical properties of steel
Steel has various physical properties that make it a versatile material for construction and manufacturing.
Density of steel is around 7.85 g/cm³
Steel is a good conductor of electricity and heat
It has high tensile strength and can withstand heavy loads
Steel is ductile and can be easily shaped into different forms
It is resistant to corrosion and rusting
Melting point of steel is around 1370°C
Top HR Questions asked in AegisCovenant