i
G R Infraprojects
Proud winner of ABECA 2024 - AmbitionBox Employee Choice Awards
Filter interviews by
I applied via Approached by Company and was interviewed in Feb 2024. There was 1 interview round.
Structural engineers work to combat factors like wind, snow, rain, and gravity on various structures.
Structural engineers design and analyze structures to ensure they can withstand different environmental conditions.
They consider factors such as wind loads, snow loads, seismic forces, and the effects of gravity on buildings and bridges.
Structural engineers use computer-aided design (CAD) software and mathematical calcu...
posted on 22 Feb 2024
I applied via LinkedIn and was interviewed in Jan 2024. There was 1 interview round.
posted on 27 Jan 2022
I applied via Company Website and was interviewed in Jan 2022. There was 1 interview round.
GFC drawing stands for Good for Construction drawing, which is a final set of drawings used for construction purposes.
GFC drawings are the final set of drawings used for construction purposes
They include all the necessary details and dimensions required for construction
GFC drawings are used by contractors and builders to construct the building as per the design
They are also used for obtaining necessary permits and appr...
I applied via campus placement at Birla Institute of Technology and Science (BITS), Pilani and was interviewed in Jul 2024. There were 3 interview rounds.
Social media connecting people
Sfd and bmd diagrams show the variation of shear force and bending moment along the length of a structural member.
SFD (Shear Force Diagram) shows the variation of shear force along the length of a beam or structural member.
BMD (Bending Moment Diagram) shows the variation of bending moment along the length of a beam or structural member.
SFD and BMD are essential for analyzing the internal forces and moments in a structu...
I am a structural engineer with 5 years of experience in designing and analyzing buildings and bridges.
Graduated with a degree in Civil Engineering
Worked on various projects including high-rise buildings and pedestrian bridges
Proficient in software such as AutoCAD and SAP2000
I am open to job locations that offer opportunities for growth and development.
I am willing to relocate for the right job opportunity
I prefer job locations with good transportation options
I am open to both urban and rural locations depending on the job requirements
I applied via Walk-in and was interviewed in Feb 2024. There was 1 interview round.
IS 2911 is the Indian Standard code for design and construction of pile foundations.
IS 2911 is the code for design and construction of pile foundations in India.
It covers various types of piles including driven piles, bored cast-in-situ piles, etc.
The code provides guidelines for the design, materials, construction, and testing of piles.
It ensures the safety and stability of structures supported by piles.
Example: IS 29...
The density of bentonite during piling is typically around 1.0 to 1.2 g/cm^3.
The density of bentonite can vary depending on the specific type and concentration used.
Higher density bentonite is often preferred for better support during piling operations.
Typical range of density for bentonite during piling is 1.0 to 1.2 g/cm^3.
posted on 15 Jun 2024
Shear key is a device used to transfer shear forces between two components in a structure.
Shear keys are typically used in construction joints to prevent sliding between adjacent components.
They are designed to resist horizontal forces and ensure stability.
Shear keys can be found in structures such as bridges, buildings, and dams.
Examples include shear keys in bridge expansion joints to prevent movement between bridge
Columns are vertical structural members that support loads, while beams are horizontal members that transfer loads to columns or walls.
Columns are vertical and primarily support compressive loads.
Beams are horizontal and primarily support bending loads.
Columns are typically taller than they are wide, while beams are typically wider than they are tall.
Examples: In a building, columns support the weight of the floors abo...
posted on 26 Aug 2023
I applied via Recruitment Consulltant and was interviewed in Jul 2023. There were 2 interview rounds.
The bolt to bolt distance depends on the specific design requirements and standards for the structural connection.
The bolt to bolt distance is typically specified in the design drawings or calculations provided by the engineer.
It is important to follow the recommended bolt to bolt distance to ensure the structural integrity of the connection.
The bolt to bolt distance may vary depending on factors such as the size and t...
Edge distance refers to the distance between the edge of a structural member and the center of a hole or fastener.
Edge distance is typically specified in design codes and standards.
It is important to maintain adequate edge distance to prevent failure of the connection.
The required edge distance can vary depending on the type of connection and the loading conditions.
For example, in steel connections, the minimum edge di...
The type of weld used for connecting a column to a base plate is typically a fillet weld.
Fillet welds are commonly used for connecting structural steel components.
The size of the fillet weld is determined based on the forces and stresses the connection will experience.
Proper welding procedures and inspections are essential to ensure the weld's quality and strength.
Column to beam joints are typically connected using various methods such as welding, bolting, or using mechanical connectors.
Common methods for connecting column to beam include welding, bolting, or using mechanical connectors
Welding is a common method where the column and beam are fused together using heat
Bolting involves using bolts to secure the column and beam together
Mechanical connectors such as shear connectors ...
The top moment column to beam top side is typically welded on the compression side of the beam.
Weld the top moment connection on the compression side of the beam for maximum strength.
Ensure proper welding techniques and inspections are followed to maintain structural integrity.
Consider using fillet welds or groove welds depending on the design requirements.
Consult structural engineering codes and standards for specific...
Edge distance of 75mm is required to cover vertical reinforcement in all types of foundations.
Edge distance is important to ensure proper anchorage and structural integrity of the reinforcement.
In this case, a minimum edge distance of 75mm is specified for covering vertical reinforcement in all types of foundations.
Examples of foundations where this requirement applies include spread footings, pile caps, and mat founda
posted on 4 May 2022
I applied via Walk-in and was interviewed in Apr 2022. There were 3 interview rounds.
I applied via Recruitment Consulltant and was interviewed in Sep 2021. There were 3 interview rounds.
posted on 18 Jan 2024
I applied via Walk-in and was interviewed in Dec 2023. There was 1 interview round.
The Fillet command is used in structural engineering to create a rounded corner between two lines or objects.
The Fillet command is used to create a smooth transition between two lines or objects by adding a rounded corner.
It is commonly used in structural engineering to create fillets at the junctions of beams, columns, and other structural elements.
The Fillet command can be used with different radius values to control...
based on 4 reviews
Rating in categories
Assistant Manager
355
salaries
| ₹4.6 L/yr - ₹11.5 L/yr |
Senior Engineer
220
salaries
| ₹3.6 L/yr - ₹8.9 L/yr |
Engineer
137
salaries
| ₹2 L/yr - ₹6.5 L/yr |
Senior Executive
133
salaries
| ₹3 L/yr - ₹7.2 L/yr |
Structural Engineer
132
salaries
| ₹2 L/yr - ₹6.3 L/yr |
Nagarjuna Construction Company
PNC Infratech
Ashoka Buildcon
IRB Infrastructure