Filter interviews by
I applied via Walk-in and was interviewed before Jan 2022. There were 4 interview rounds.
Calculations, questions related to installation works
The voltage drop for a cable length of 40m depends on the cable size, current flow, and resistance.
The cable size and current flow determine the resistance of the cable.
The resistance of the cable determines the voltage drop.
The voltage drop can be calculated using Ohm's Law: V = IR.
For example, a 40m length of 2.5mm² cable carrying a current of 10A would have a voltage drop of approximately 1.6V.
Top trending discussions
posted on 16 Feb 2023
I applied via Indeed and was interviewed before Feb 2022. There were 2 interview rounds.
posted on 16 Mar 2022
I applied via Naukri.com and was interviewed in Feb 2022. There were 2 interview rounds.
posted on 7 Feb 2022
I applied via Company Website and was interviewed in Jan 2022. There were 2 interview rounds.
posted on 27 Sep 2024
I was interviewed in Aug 2024.
Steel is used in construction works due to its strength, durability, versatility, and cost-effectiveness.
Steel is known for its high tensile strength, making it ideal for supporting heavy loads in buildings and bridges.
Steel is durable and resistant to corrosion, ensuring the longevity of structures.
Steel can be easily fabricated into different shapes and sizes, allowing for versatile design options.
Steel is cost-effec...
Concrete cover is provided in all structural members to protect the reinforcement bars from corrosion and fire damage.
Concrete cover protects the reinforcement bars from corrosion caused by exposure to moisture and chemicals in the environment.
It also provides protection against fire damage by acting as a barrier between the reinforcement and the fire.
Proper concrete cover helps in maintaining the durability and streng...
Calculate the amount of steel required for a staircase based on design and dimensions.
Calculate the total length of all the steel bars needed for the staircase
Determine the diameter and spacing of the steel bars based on design requirements
Consider the number of steps and the dimensions of the staircase in the calculation
Account for any additional reinforcement needed for structural integrity
Consult structural drawings
Concrete workability can be determined by conducting a slump test.
Conduct a slump test to measure the consistency of the concrete mix.
Adjust the water content or use admixtures to achieve the desired workability.
Consider factors such as temperature, humidity, and type of aggregates in determining workability.
Consult with concrete mix design experts for guidance on achieving the desired workability.
Use tools like flow t...
Slump test is a method to measure the consistency of concrete before it sets.
Slump test involves filling a cone-shaped mold with concrete, then lifting the mold to see how much the concrete slumps or settles.
The amount of slump indicates the workability of the concrete - higher slump means more workable concrete.
The test helps ensure the concrete is of the right consistency for proper placement and compaction.
Slump tes...
Concrete mix design is the process of selecting suitable ingredients and determining their proportions to produce concrete with desired properties.
Involves selecting the right combination of materials like cement, aggregates, water, and admixtures
Proportions are determined based on desired strength, workability, durability, and other properties
Testing and adjusting the mix design to meet project requirements
Example: A ...
I applied via Walk-in and was interviewed before May 2021. There were 2 interview rounds.
CODAL provisions for concrete refer to the guidelines and regulations set by relevant authorities, while commands of software are the specific instructions or functions within a software program.
CODAL provisions for concrete include specifications for mix design, strength requirements, and durability standards.
Commands of software for site engineers may include functions for structural analysis, quantity takeoff, and p...
I applied via Naukri.com and was interviewed in Jan 2023. There were 3 interview rounds.
Hydro power test of DI pipes is a method to check the strength and integrity of ductile iron pipes under pressure.
Hydro power test involves filling the DI pipes with water and pressurizing them to a specified level.
The test is conducted to ensure that the pipes can withstand the pressure they will be subjected to in actual use.
Leaks or deformations during the test indicate weaknesses in the pipes.
The test helps in iden...
posted on 27 Sep 2023
I applied via Referral and was interviewed before Sep 2022. There were 2 interview rounds.
System studies involve analyzing and evaluating the performance of electrical systems to ensure efficiency and reliability.
System studies involve analyzing the behavior of electrical systems under different operating conditions.
They help identify potential issues and optimize the performance of the system.
Examples of system studies include load flow analysis, short circuit analysis, and protection coordination studies.
Load flow study is a method used in electrical engineering to analyze and calculate the flow of power in an electrical network.
Load flow study helps in determining the steady-state operating conditions of a power system.
It involves calculating the voltage magnitude and phase angle at each bus in the network.
The study considers factors like power generation, transmission line losses, and load demand.
It helps in identify...
posted on 10 Jul 2021
I was interviewed in Jan 2021.
Yes, I have installed transformers and panels in various projects.
I have experience in installing transformers and panels in both commercial and residential projects.
I am familiar with the wiring and connections required for proper installation.
I have worked with different types of transformers such as step-up, step-down, and isolation transformers.
I have also installed various types of panels such as distribution pane...
Yes, I have experience handling ELV packages independently.
I have worked on multiple projects where I was solely responsible for the ELV package.
I am familiar with the design and installation of ELV systems such as fire alarm, CCTV, access control, and PA systems.
I have experience coordinating with other trades to ensure proper integration of ELV systems.
I am confident in my ability to handle any challenges that may ar
based on 1 review
Rating in categories
Civil Site Engineer
3
salaries
| ₹4 L/yr - ₹4 L/yr |
Facade Project Engineer
3
salaries
| ₹20.5 L/yr - ₹33.5 L/yr |
Megha Engineering & Infrastructures
Shapoorji Pallonji Group
Alstom Transportation
Tata Technologies