During conveyor inspection, you need to observe various aspects to ensure its proper functioning.
Check for any signs of wear and tear on the conveyor belt
Inspect the rollers and ensure they are rotating smoothly
Look for any loose or damaged components, such as bolts or fasteners
Check the tension of the conveyor belt and adjust if necessary
Observe the alignment of the belt and make any necessary adjustments
Inspect the c...
The process of oil top-up in a fluid coupling involves adding oil to maintain the desired level and ensure proper functioning.
Check the oil level in the fluid coupling regularly
Identify the oil fill point on the fluid coupling
Use the appropriate type and grade of oil recommended by the manufacturer
Slowly pour the oil into the fill point until the desired level is reached
Avoid overfilling the fluid coupling as it can le...
Top trending discussions
posted on 19 Jul 2023
I applied via Referral and was interviewed before Jul 2022. There were 3 interview rounds.
Synchronous motors operate at a constant speed determined by the frequency of the power source.
Synchronous motors have a rotor that rotates at the same speed as the rotating magnetic field in the stator.
They are used in applications where constant speed is required, such as in industrial processes or power generation.
Synchronous motors are more efficient than induction motors at higher loads.
They require a separate DC ...
Induction motors rely on induction to produce torque, while synchronous motors require a magnetic field to rotate at a constant speed.
Induction motors do not require any external connections to the rotor, while synchronous motors need a DC power source to create the magnetic field.
Induction motors are self-starting, while synchronous motors require external means to start.
Induction motors are more commonly used in indu...
I applied via Company Website and was interviewed in Mar 2023. There were 3 interview rounds.
Normal introduction and interview
There are various types of electrical motors including AC motors, DC motors, synchronous motors, and induction motors.
AC motors: commonly used in household appliances and industrial applications
DC motors: used in applications where speed control is important, such as in electric vehicles
Synchronous motors: used in applications where precise speed control is required, such as in clocks and timers
Induction motors: widely...
Protection of transformer involves measures to prevent damage from overcurrent, overvoltage, and overheating.
Use overcurrent protection devices such as fuses and circuit breakers to prevent damage from excessive current flow.
Install overvoltage protection devices like surge arresters to safeguard against voltage spikes.
Implement temperature monitoring systems to prevent overheating, such as thermal sensors and cooling ...
DOL starter stands for Direct-On-Line starter, used to start motors by directly connecting them to the power supply.
DOL starter is the simplest and most common type of motor starter.
It directly connects the motor to the power supply without any intermediate starting method.
It provides full voltage to the motor during starting, which can cause high inrush current.
DOL starters are suitable for small to medium-sized motor...
APFC PANEL stands for Automatic Power Factor Correction Panel, used to maintain power factor in electrical systems.
APFC PANEL automatically monitors and corrects the power factor of electrical systems.
It helps in reducing electricity bills by maintaining a high power factor.
APFC PANELs are commonly used in industries and commercial buildings.
They consist of capacitors that are switched on and off based on the load requ...
posted on 25 Oct 2023
posted on 28 Dec 2022
I applied via Naukri.com and was interviewed in Jun 2022. There were 2 interview rounds.
ATS stands for Automatic Transfer Switch. It is used to transfer power supply between two sources. Transformer and motor maintenance procedures and protection methods are essential for their efficient operation. SAP is a software used for enterprise resource planning.
ATS is used to automatically switch power supply between two sources, ensuring uninterrupted power supply.
Transformer maintenance involves regular inspect...
HT motor rating is the maximum power it can handle and FLC is the current it draws at full load.
HT motor rating is expressed in kilowatts (kW) or megawatts (MW).
FLC of HT motor is the full load current it draws at rated voltage and frequency.
FLC is expressed in amperes (A) and varies depending on the motor's power rating and efficiency.
For example, a 1 MW HT motor may have a FLC of 1000 A at 11 kV.
The rating and FLC of...
Plant EHT system and single line diagram of plants.
EHT system refers to Extra High Tension system used in power plants
Single line diagram shows the electrical connections between different components
It is important to have a clear and accurate diagram for safety and maintenance purposes
posted on 11 Feb 2024
I was interviewed before Feb 2023.
The major parts in a power transformer include the core, windings, insulation, cooling system, and tap changer.
Core: Provides a path for magnetic flux and is usually made of laminated steel sheets.
Windings: Consist of primary and secondary coils that transfer electrical energy.
Insulation: Prevents electrical leakage and ensures safety.
Cooling System: Keeps the transformer within operating temperature limits, commonly u...
I want to switch electrical circuits and devices.
Switching electrical circuits to control the flow of electricity.
Switching electrical devices on or off.
Switching between different power sources.
Switching between different modes or settings of electrical equipment.
Switching between different electrical connections or configurations.
I applied via campus placement at KLN College of Engineering, Madurai and was interviewed before Sep 2021. There were 3 interview rounds.
Just work with R.S. Aggarwal book
I applied via Naukri.com and was interviewed in Jan 2021. There was 1 interview round.
Interview experience
based on 11 reviews
Rating in categories
Mechanical Engineer
122
salaries
| ₹1.6 L/yr - ₹5.6 L/yr |
Shift Incharge
68
salaries
| ₹2.5 L/yr - ₹7.6 L/yr |
Safety Officer
55
salaries
| ₹2.6 L/yr - ₹5.3 L/yr |
Mechanical Maintenance Engineer
51
salaries
| ₹2.3 L/yr - ₹7.2 L/yr |
Shift Engineer
45
salaries
| ₹2.5 L/yr - ₹5 L/yr |
Thermax Limited
Kirloskar Brothers
BHEL
Larsen & Toubro Limited