Explanation of tan delta test and winding test in transformers
Tan delta test measures the insulation quality of transformer windings
It is performed to detect any insulation defects or aging in the transformer
The value of tan delta should be low, ideally less than 0.5%
Winding test is performed to check the integrity of transformer windings
It helps to detect any short circuits or open circuits in the winding
Manufactured ...
I applied via Company Website
I applied via Recruitment Consulltant and was interviewed before Feb 2022. There were 2 interview rounds.
I applied via Naukri.com and was interviewed in Feb 2021. There were 5 interview rounds.
TP Central Odisha Distribution interview questions for designations
I applied via Company Website and was interviewed in Dec 2020. There was 1 interview round.
Top trending discussions
I applied via Naukri.com and was interviewed in Jul 2022. There were 3 interview rounds.
Supervision of Solar plants, Liaising with govt bodies related to theft and miss happenings, action emergency task with immediate effect like firefighting, mock drills & ets, investigation, interrogation, supervision security installation.
Prophylactic security, intelligence tasks, vigilance, surveillance, transport management.
Magnetic core balance test is done to measure the balance of magnetic cores in a transformer.
The test is performed by injecting a current into one winding of the transformer and measuring the voltage induced in the other winding.
The test is repeated for each winding of the transformer.
The results are compared to determine if the magnetic cores are balanced.
If the magnetic cores are not balanced, it can lead to increase...
Power factor is a measure of how effectively electrical power is being used and it affects the efficiency of electrical systems.
Power factor is the ratio of real power (kW) to apparent power (kVA) in an electrical system.
It indicates how much of the total power is being used for useful work.
A power factor of 1 means all the power is being used effectively, while a power factor less than 1 indicates inefficiency.
Low pow...
Active power is the actual power consumed by a device or system.
Active power is measured in watts (W).
It is the power that is actually doing the work.
It is the product of voltage and current in an AC circuit.
It is also known as real power.
For example, a 100W light bulb consumes 100W of active power.
I applied via Referral and was interviewed in Feb 2022. There were 4 interview rounds.
About your previous company experience
I applied via Company Website and was interviewed before Dec 2022. There were 3 interview rounds.
Some of the top questions asked at the TP Central Odisha Distribution Senior Officer interview -
based on 1 interview
Interview experience
based on 4 reviews
Rating in categories
Lead Engineer
98
salaries
| ₹3.5 L/yr - ₹8.7 L/yr |
Team Lead
96
salaries
| ₹3.8 L/yr - ₹15.5 L/yr |
Senior Officer
13
salaries
| ₹3.5 L/yr - ₹6.7 L/yr |
Associate Lead
11
salaries
| ₹8.5 L/yr - ₹12 L/yr |
Officer
10
salaries
| ₹3 L/yr - ₹4.8 L/yr |
Suzlon Group
Adani Power
Adani Group
NTPC