Filter interviews by
I applied via Other
Yes
Proficient in reading and interpreting electrical diagrams
Familiarity with symbols, circuitry, and components used in electrical diagrams
Ability to understand wiring connections and troubleshoot electrical systems
Experience with schematic diagrams, block diagrams, and ladder logic diagrams
Knowledge of electrical codes and standards
Top trending discussions
posted on 9 May 2023
I applied via Recruitment Consulltant and was interviewed before May 2022. There were 2 interview rounds.
I have handled testing of various electrical equipment including transformers, switchgears, motors, generators, and control panels.
Testing of transformers for insulation resistance, winding resistance, turns ratio, and polarity
Testing of switchgears for insulation resistance, contact resistance, and operation
Testing of motors for insulation resistance, winding resistance, and no-load and load testing
Testing of generato...
I was interviewed before Aug 2016.
Switchgear is a combination of electrical disconnect switches, fuses, or circuit breakers used to control, protect, and isolate electrical equipment.
Switchgear is a general term for a collection of devices used to control, protect, and isolate electrical equipment.
Circuit breakers are a type of switchgear that automatically interrupts the flow of electric current when a fault is detected.
Switchgear can include disconne...
The interface between transformer and switch gears is the electrical connection and communication between the two components.
The transformer and switch gears are connected through electrical cables or busbars.
The switch gears control the flow of electrical power to and from the transformer.
The switch gears may include circuit breakers, relays, and protective devices.
The interface ensures proper coordination and protect...
The value of IBL of Transformer oil is the Insulating Breakdown Level.
IBL is a measure of the dielectric strength of transformer oil.
It indicates the maximum voltage that the oil can withstand before it breaks down and loses its insulating properties.
The IBL value is important for ensuring the safe and reliable operation of transformers.
Regular testing of transformer oil is necessary to monitor the IBL and detect any p...
Yes, I am ready for re-location.
I am open to moving to a new location for the right opportunity.
I have experience working in different cities and adapting to new environments.
I am willing to relocate to further my career and gain new experiences.
I understand the challenges that come with re-location and I am prepared to face them.
I have a flexible mindset and can easily adjust to new surroundings.
posted on 9 May 2023
I applied via Recruitment Consulltant and was interviewed before May 2022. There were 2 interview rounds.
I have handled testing of various electrical equipment including transformers, switchgears, motors, generators, and control panels.
Testing of transformers for insulation resistance, winding resistance, turns ratio, and polarity
Testing of switchgears for insulation resistance, contact resistance, and operation
Testing of motors for insulation resistance, winding resistance, and no-load and load testing
Testing of generato...
posted on 29 Oct 2021
I was interviewed in Sep 2021.
I was interviewed before Aug 2016.
Switchgear is a combination of electrical disconnect switches, fuses, or circuit breakers used to control, protect, and isolate electrical equipment.
Switchgear is a general term for a collection of devices used to control, protect, and isolate electrical equipment.
Circuit breakers are a type of switchgear that automatically interrupts the flow of electric current when a fault is detected.
Switchgear can include disconne...
The interface between transformer and switch gears is the electrical connection and communication between the two components.
The transformer and switch gears are connected through electrical cables or busbars.
The switch gears control the flow of electrical power to and from the transformer.
The switch gears may include circuit breakers, relays, and protective devices.
The interface ensures proper coordination and protect...
The value of IBL of Transformer oil is the Insulating Breakdown Level.
IBL is a measure of the dielectric strength of transformer oil.
It indicates the maximum voltage that the oil can withstand before it breaks down and loses its insulating properties.
The IBL value is important for ensuring the safe and reliable operation of transformers.
Regular testing of transformer oil is necessary to monitor the IBL and detect any p...
Yes, I am ready for re-location.
I am open to moving to a new location for the right opportunity.
I have experience working in different cities and adapting to new environments.
I am willing to relocate to further my career and gain new experiences.
I understand the challenges that come with re-location and I am prepared to face them.
I have a flexible mindset and can easily adjust to new surroundings.
Bombardier Transportation
Hyva
Intact Green Services
Indian Railway Catering and Tourism