Chillers like run building cooling Purpose in internal Floor Ahu mataine Cooling system
Primary And Secondary pumps Run water flow mataine Chiller Cooing system in Floor Ahus .. Ahu blower Freqance Slow or speed auto Running Truths in vfd
Split gas leakages , drain water leakage issues, Gas Charging ac unit Fan Moter, blower Working also we Rectifed
Water cooled chillers require proper water treatment and maintenance to ensure efficient operation and prevent corrosion and scale buildup.
Water quality must be monitored and treated regularly to prevent corrosion and scale buildup
Proper water flow and pressure must be maintained to ensure efficient heat transfer
Regular maintenance of the chiller and its components is necessary to prevent breakdowns and ensure optimal ...
R.O plant working conditions refer to the environment and factors affecting the operation of a reverse osmosis plant.
Temperature and humidity levels should be controlled to prevent damage to equipment
Water quality should be monitored regularly to ensure optimal performance
Proper ventilation is necessary to prevent buildup of harmful gases
Maintenance and cleaning schedules should be followed to prevent contamination
Safe...
Chiller inlet and outlet conditions refer to the temperature and pressure of the fluid entering and leaving the chiller.
Inlet conditions include temperature, pressure, and flow rate of the fluid entering the chiller.
Outlet conditions include temperature, pressure, and flow rate of the fluid leaving the chiller.
Monitoring and adjusting these conditions is crucial for efficient chiller operation.
Examples of inlet and out...
AHU blowers conditions refer to the state of the air handling unit's fans.
The condition of AHU blowers affects the airflow and temperature control of the HVAC system.
Dirty or damaged blowers can cause reduced efficiency and increased energy consumption.
Regular maintenance and cleaning of AHU blowers is important to ensure optimal performance.
AHU blowers should be inspected for wear and tear, and replaced if necessary.
P...
Ahu inlet and outlet water conditions are important for proper functioning of HVAC system.
Water temperature should be within the specified range
Water flow rate should be adequate
Water quality should be maintained to prevent corrosion and scaling
Water pressure should be monitored to avoid leaks and damage to equipment
Top trending discussions
posted on 8 Aug 2024
I applied via AmbitionBox and was interviewed in Feb 2024. There was 1 interview round.
posted on 8 Aug 2024
I applied via AmbitionBox and was interviewed in Feb 2024. There was 1 interview round.
posted on 9 Sep 2024
The compressor is removed by disconnecting electrical connections, refrigerant lines, and mounting bolts.
Disconnect electrical connections to the compressor
Disconnect refrigerant lines from the compressor
Remove mounting bolts securing the compressor in place
Carefully lift and remove the compressor from its location
I applied via Walk-in and was interviewed in Dec 2022. There were 3 interview rounds.
Interview experience
based on 1 review
Rating in categories
Site Engineer
55
salaries
| ₹3.2 L/yr - ₹5.2 L/yr |
Senior Engineer
45
salaries
| ₹4.3 L/yr - ₹8.5 L/yr |
Assistant Manager
41
salaries
| ₹4.8 L/yr - ₹10.2 L/yr |
Civil Site Engineer
40
salaries
| ₹3.2 L/yr - ₹5.7 L/yr |
Executive Accountant
40
salaries
| ₹2.2 L/yr - ₹5.5 L/yr |
Prestige Group
Brigade Group
Godrej Properties
DLF