Chillers like run building cooling Purpose in internal Floor Ahu mataine Cooling system
Primary And Secondary pumps Run water flow mataine Chiller Cooing system in Floor Ahus .. Ahu blower Freqance Slow or speed auto Running Truths in vfd
Split gas leakages , drain water leakage issues, Gas Charging ac unit Fan Moter, blower Working also we Rectifed
Water cooled chillers require proper water treatment and maintenance to ensure efficient operation and prevent corrosion and scale buildup.
Water quality must be monitored and treated regularly to prevent corrosion and scale buildup
Proper water flow and pressure must be maintained to ensure efficient heat transfer
Regular maintenance of the chiller and its components is necessary to prevent breakdowns and ensure optimal ...
R.O plant working conditions refer to the environment and factors affecting the operation of a reverse osmosis plant.
Temperature and humidity levels should be controlled to prevent damage to equipment
Water quality should be monitored regularly to ensure optimal performance
Proper ventilation is necessary to prevent buildup of harmful gases
Maintenance and cleaning schedules should be followed to prevent contamination
Safe...
Chiller inlet and outlet conditions refer to the temperature and pressure of the fluid entering and leaving the chiller.
Inlet conditions include temperature, pressure, and flow rate of the fluid entering the chiller.
Outlet conditions include temperature, pressure, and flow rate of the fluid leaving the chiller.
Monitoring and adjusting these conditions is crucial for efficient chiller operation.
Examples of inlet and out...
AHU blowers conditions refer to the state of the air handling unit's fans.
The condition of AHU blowers affects the airflow and temperature control of the HVAC system.
Dirty or damaged blowers can cause reduced efficiency and increased energy consumption.
Regular maintenance and cleaning of AHU blowers is important to ensure optimal performance.
AHU blowers should be inspected for wear and tear, and replaced if necessary.
P...
Ahu inlet and outlet water conditions are important for proper functioning of HVAC system.
Water temperature should be within the specified range
Water flow rate should be adequate
Water quality should be maintained to prevent corrosion and scaling
Water pressure should be monitored to avoid leaks and damage to equipment
Top trending discussions
I applied via Naukri.com and was interviewed before Jun 2022. There were 3 interview rounds.
I applied via Naukri.com and was interviewed before Jul 2023. There was 1 interview round.
posted on 12 Apr 2021
I applied via Naukri.com and was interviewed in Mar 2021. There was 1 interview round.
A 2-way switch is a type of electrical switch that allows control of a single light or electrical device from two different locations.
A 2-way switch is commonly used in staircases, hallways, and rooms with multiple entrances.
It has three terminals: a common terminal and two traveler terminals.
The common terminal is connected to the power source, while the traveler terminals are connected to the light or device.
When one...
A 2 way switch is a type of electrical switch that allows control of a single light or set of lights from two different locations.
Also known as a two-way switch or a single-pole double-throw (SPDT) switch
Commonly used in staircases, hallways, and large rooms with multiple entry points
Requires three wires: a live wire, a switched live wire, and a neutral wire
Can be wired in a circuit with multiple 2 way switches to cont...
posted on 1 Oct 2023
I applied via Referral and was interviewed in Apr 2023. There were 3 interview rounds.
I applied via Walk-in and was interviewed in Jun 2021. There were 3 interview rounds.
I applied via Approached by Company and was interviewed in Oct 2023. There were 4 interview rounds.
I applied via Walk-in and was interviewed in Dec 2022. There were 3 interview rounds.
I applied via Approached by Company and was interviewed in Jan 2023. There were 4 interview rounds.
Copy Monitor is a Revit tool that allows users to monitor and synchronize changes made to linked models.
Copy Monitor is used in Revit to ensure that changes made to linked models are reflected in the current model.
It allows users to monitor and synchronize changes made to linked models.
Copy Monitor can be used to track changes to elements such as walls, floors, and roofs.
It can also be used to monitor changes to parame...
Revit models can be linked using the 'Link Revit' tool in the 'Insert' tab.
Open the host model and go to the 'Insert' tab.
Click on 'Link Revit' and select the model to be linked.
Choose the appropriate settings for the link, such as positioning and visibility.
Repeat the process for any additional models to be linked.
Save the host model to ensure the links are maintained.
They gave an architectural model to create a structural model
I applied via Naukri.com and was interviewed in May 2021. There were 4 interview rounds.
based on 1 interview
Interview experience
based on 1 review
Rating in categories
Site Engineer
58
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Engineer
45
salaries
| ₹0 L/yr - ₹0 L/yr |
Assistant Manager
40
salaries
| ₹0 L/yr - ₹0 L/yr |
Civil Site Engineer
40
salaries
| ₹0 L/yr - ₹0 L/yr |
Executive Accountant
40
salaries
| ₹0 L/yr - ₹0 L/yr |
Prestige Group
Brigade Group
Godrej Properties
DLF