HVAC stands for Heating, Ventilation, and Air Conditioning. UPS stands for Uninterruptible Power Supply. AHU stands for Air Handling Unit.
HVAC refers to the technology used for indoor environmental comfort, including heating, cooling, and air quality control.
UPS is a device that provides emergency power to a load when the input power source fails.
AHU is a device used to regulate and circulate air as part of a heating,
An air cold chiller is a device that cools air by removing heat from it.
An air cold chiller is commonly used in air conditioning systems to cool indoor spaces.
It works by circulating a refrigerant that absorbs heat from the air and then releases it outside.
The chilled air is then distributed through ducts or vents to cool the desired area.
Air cold chillers can be used in various settings such as homes, offices, hospita...
An AHU (Air Handling Unit) is a device used to regulate and circulate air as part of a heating, ventilation, and air conditioning (HVAC) system.
AHU is an abbreviation for Air Handling Unit.
It is a device used in HVAC systems to control and distribute air.
AHUs typically consist of a fan, heating and cooling coils, filters, and dampers.
They are responsible for conditioning and circulating air within a building.
AHUs can b...
LP stands for Low Pass and HP stands for High Pass.
LP (Low Pass) is a type of filter that allows low-frequency signals to pass through while attenuating high-frequency signals.
HP (High Pass) is a type of filter that allows high-frequency signals to pass through while attenuating low-frequency signals.
LP and HP filters are commonly used in audio systems to control the frequency range of the output signal.
LP filters are ...
A UPS (Uninterruptible Power Supply) is a device that provides emergency power to a load when the input power source fails.
UPS is used to protect critical equipment from power outages, voltage fluctuations, and other power-related issues.
It typically consists of a battery, an inverter, and a rectifier.
UPS can be used for various applications such as computers, data centers, hospitals, telecommunications, etc.
Examples o...
PAC stands for Programmable Automation Controller. It is a device used in industrial automation to control and monitor processes.
PAC is a type of controller used in industrial automation systems.
It is programmable and can be customized to control and monitor various processes.
PACs are often used in manufacturing plants, power plants, and other industrial settings.
They can communicate with other devices and systems to g...
A water cold chiller is a device that cools water by removing heat from it, typically used in air conditioning systems or industrial processes.
A water cold chiller uses a refrigeration cycle to cool water.
It consists of components such as a compressor, condenser, expansion valve, and evaporator.
The chiller circulates chilled water through a system to remove heat from the surroundings.
It is commonly used in air conditio...
ACB stands for Air Circuit Breaker and VCB stands for Vacuum Circuit Breaker.
ACB is a type of circuit breaker that uses air as the medium to extinguish the arc.
VCB is a type of circuit breaker that uses vacuum as the medium to extinguish the arc.
Both ACB and VCB are used for electrical circuit protection and can interrupt the flow of current in case of faults.
ACBs are commonly used in low voltage applications, while VC...
Precision air conditioning units are commonly used in server rooms.
Precision air conditioning units are designed to provide precise temperature and humidity control.
These units are capable of maintaining stable and optimal conditions for sensitive equipment like servers.
They often feature redundant systems for reliability and may include features like hot aisle/cold aisle containment.
Examples of precision air condition...
A CSU, or Channel Service Unit, is a device used in telecommunications to connect a digital line to a customer's equipment.
CSU stands for Channel Service Unit.
It is used in telecommunications to connect a digital line to a customer's equipment.
CSUs provide signal regeneration, line coding, and diagnostic capabilities.
They ensure reliable transmission of data over long distances.
Examples of CSUs include T1 CSUs, ISDN CS
I applied via Approached by Company and was interviewed in Mar 2024. There were 2 interview rounds.
Sr.enjineer mock test
I applied via Referral and was interviewed before Apr 2021. There were 2 interview rounds.
posted on 2 Mar 2021
I applied via Naukri.com and was interviewed before Mar 2020. There were 6 interview rounds.
posted on 15 Jun 2024
Check point of plastering is a crucial step in ensuring a smooth and even finish on walls or ceilings.
Check for any uneven areas or bumps in the plaster surface
Ensure that the plaster is fully dried before proceeding to the next step
Use a straight edge or level to check for any dips or high spots in the plaster
Inspect the corners and edges for any rough or unfinished areas
Make sure to sand down any rough patches before
Check points of water proofing involves inspecting areas prone to water leakage and ensuring proper sealing and protection.
Inspecting roof for cracks or missing shingles
Checking windows and doors for gaps or faulty seals
Examining foundation for signs of water seepage
Testing waterproofing membranes in basements or bathrooms
based on 1 interview
Interview experience
MEP Supervisor
9
salaries
| ₹8 L/yr - ₹12 L/yr |
Hvac Technician
8
salaries
| ₹3 L/yr - ₹7.2 L/yr |
Electrical Technician
8
salaries
| ₹4.8 L/yr - ₹9 L/yr |
Vice President
6
salaries
| ₹36 L/yr - ₹60 L/yr |
Facility Engineer
6
salaries
| ₹9 L/yr - ₹21 L/yr |
Sobha
Lodha Group
Cushman & Wakefield
Godrej Properties