Filter interviews by
The appropriate size for a beam depends on factors such as load, span, material, and building codes.
Consider the load the beam will need to support
Calculate the span of the beam
Select an appropriate material for the beam based on strength and durability
Ensure the beam meets building code requirements for safety
I applied via Campus Placement and was interviewed before Jul 2021. There were 4 interview rounds.
Based own question asked by judges
I applied via Company Website and was interviewed in May 2021. There was 1 interview round.
I applied via Referral and was interviewed in Aug 2022. There were 3 interview rounds.
Aluminium formwork is a construction technique that uses lightweight aluminium panels to form concrete walls, floors, and columns.
Aluminium formwork is a modern construction technique that is faster and more efficient than traditional formwork methods.
It involves using lightweight aluminium panels that are easy to handle and can be reused multiple times.
The panels are assembled on site to form the desired shape and siz...
Waterproofing procedure involves applying a waterproof barrier to prevent water from penetrating a building structure.
Identify the areas that need waterproofing such as roofs, walls, and foundations.
Choose the appropriate waterproofing material based on the type of structure and the level of water exposure.
Prepare the surface by cleaning and repairing any cracks or damage.
Apply the waterproofing material using the reco...
Steel Fibre Road Concrete is a type of concrete that contains steel fibres to improve its strength and durability.
Steel fibres are added to the concrete mix to enhance its mechanical properties.
The fibres act as reinforcement and help to prevent cracking and improve resistance to wear and tear.
Steel Fibre Road Concrete is commonly used in the construction of roads, bridges, and other infrastructure projects.
It is also ...
I have experience in piling works including design, installation, and testing of piles.
Designed pile foundations for various structures including bridges and buildings
Installed piles using various methods such as driven piles and drilled shafts
Conducted pile load tests to ensure the capacity of the piles
Managed and supervised piling works on construction sites
Ensured compliance with safety regulations and quality stand
Concrete technology is crucial for site activity as it involves the proper mixing, placing, and curing of concrete.
Understanding the properties of concrete and how it reacts to different conditions
Proper mixing of concrete ingredients to achieve the desired strength and consistency
Ensuring proper placement and compaction of concrete to avoid voids and weak spots
Proper curing of concrete to achieve maximum strength and ...
I completed various projects during my Bachelor's degree, including a design project for a new bridge and a research project on renewable energy.
Designed a new bridge using CAD software
Researched and implemented renewable energy sources on campus
Collaborated with classmates on a group project to improve campus sustainability
I completed my 6 months internship at ABC Engineering Firm, where I gained hands-on experience in project management and design.
Internship at ABC Engineering Firm
Focused on project management and design
Hands-on experience gained
Low tension cables rated for 440V are commonly used for power distribution in residential and commercial buildings.
Low tension cables are typically rated for voltages up to 1000V.
These cables are commonly used for power distribution in buildings.
Examples of low tension cables include PVC insulated cables and XLPE insulated cables.
I applied via Referral and was interviewed before Jul 2023. There was 1 interview round.
Density of materials is a measure of mass per unit volume.
Density is calculated by dividing the mass of a material by its volume.
Common units for density include g/cm^3, kg/m^3, and lb/ft^3.
Materials with higher density are heavier for their size, while materials with lower density are lighter.
For example, gold has a high density of 19.3 g/cm^3, while air has a low density of 0.0012 g/cm^3.
Testing of materials involves evaluating their physical, mechanical, and chemical properties to ensure quality and performance.
Materials are tested to determine their strength, durability, and suitability for specific applications.
Common testing methods include tensile testing, hardness testing, impact testing, and chemical analysis.
Testing helps identify any defects or weaknesses in materials before they are used in p...
I appeared for an interview in Feb 2025, where I was asked the following questions.
I applied via Company Website and was interviewed before Jan 2023. There was 1 interview round.
Chiller efficiency is a measure of how well a chiller unit is able to cool a space while using the least amount of energy.
Chiller efficiency is typically measured by the Coefficient of Performance (COP), which is the ratio of cooling output to energy input.
Regular maintenance and cleaning of chiller components can improve efficiency.
Upgrading to a more energy-efficient chiller model can also increase efficiency.
Proper ...
Water cooled systems are generally more efficient than air cooled systems due to higher heat transfer capabilities.
Water has higher heat transfer capabilities compared to air
Water cooled systems can maintain more consistent temperatures
Water cooled systems are typically used in high performance applications such as data centers and industrial machinery
Duct velocity can be improved by increasing the fan speed or reducing the duct size.
Increase the fan speed to increase the air velocity in the duct.
Reduce the duct size to increase the air velocity.
Use dampers or adjustable louvers to control and optimize the airflow.
Ensure proper sealing of duct joints to minimize air leakage.
Consider using smooth and straight ducts to reduce friction and improve airflow.
Regularly cle...
The chiller system uses various types of gases for cooling purposes.
Common types of gases used in chiller systems include R-134a, R-410A, and ammonia.
R-134a is a hydrofluorocarbon (HFC) refrigerant commonly used in air conditioning systems.
R-410A is a blend of hydrofluorocarbons used as a replacement for older refrigerants.
Ammonia (NH3) is often used in industrial chiller systems due to its high cooling capacity.
Other ...
The VRF system capacity is determined based on the area's cooling and heating load requirements.
Calculate the total cooling load and heating load for the area
Consider factors such as insulation, windows, occupancy, and equipment
Select VRF system capacity based on the calculated load requirements
Consult with HVAC professionals for accurate sizing
based on 1 interview
Interview experience
based on 6 reviews
Rating in categories
Assistant Manager
87
salaries
| ₹4.3 L/yr - ₹9.5 L/yr |
Engineer
58
salaries
| ₹2 L/yr - ₹5.1 L/yr |
Senior Engineer
58
salaries
| ₹3.5 L/yr - ₹7 L/yr |
Quality Engineer
46
salaries
| ₹1.5 L/yr - ₹5.5 L/yr |
Senior Executive
30
salaries
| ₹3.6 L/yr - ₹6.4 L/yr |
Knight Frank
Berkadia
Smartworks
Xanadu