Filter interviews by
I was interviewed in Dec 2024.
I applied via Company Website and was interviewed before Dec 2022. There were 3 interview rounds.
Top trending discussions
I applied via Company Website and was interviewed in Sep 2022. There were 4 interview rounds.
The qualification for an Instrumentation Technician typically includes a degree or diploma in instrumentation technology or a related field.
A degree or diploma in instrumentation technology or a related field is usually required.
Knowledge of electrical and electronic systems is important.
Experience with calibration and troubleshooting of instruments is often necessary.
Familiarity with industry standards and regulations...
Thermocouple range refers to the temperature range within which a thermocouple can accurately measure temperature.
Thermocouple range varies depending on the type of thermocouple used.
Common thermocouple types include J, K, T, E, and N.
For example, a type K thermocouple has a range of -200 to 1350 degrees Celsius.
It is important to select the appropriate thermocouple type for the temperature range being measured.
An anti-surge valve is a control valve used in a compressor system to prevent surge and maintain stable operation.
An anti-surge valve is typically installed in the discharge line of a compressor.
It is designed to protect the compressor from surge, which is a phenomenon of unstable flow and pressure that can cause damage to the compressor.
The valve opens or closes based on the compressor's operating conditions to mainta...
Yes, I have experience working with gas turbines.
I have worked with gas turbines in my previous job as an instrumentation technician.
I am familiar with the maintenance and troubleshooting of gas turbines.
I have experience in calibrating and testing gas turbine sensors and instruments.
I have knowledge of the safety protocols and regulations related to gas turbines.
There are three types of vibration in the field: axial, radial, and tangential.
Axial vibration occurs parallel to the axis of rotation.
Radial vibration occurs perpendicular to the axis of rotation.
Tangential vibration occurs at a right angle to both axial and radial vibration.
Vibration analysis is used to detect and diagnose problems in rotating machinery.
Excessive vibration can lead to premature failure of bearings, g
Yes, I am familiar with preventive maintenance jobs.
Preventive maintenance involves regularly scheduled inspections, cleaning, and repairs to prevent equipment breakdowns.
I have experience performing preventive maintenance on various types of instrumentation equipment, such as calibrators, transmitters, and controllers.
Examples of preventive maintenance tasks I have performed include checking for leaks, replacing worn ...
Precautions are necessary to ensure safe and efficient plant operation.
Regular maintenance of equipment and machinery
Proper training and certification of personnel
Strict adherence to safety protocols and procedures
Regular inspections and audits to identify potential hazards
Effective communication and coordination among team members
Use of personal protective equipment (PPE) as required
Emergency response planning and dri...
I am interested to work in maintenance field and troubleshooting
posted on 15 Jun 2023
I applied via Campus Placement
It was an online assessment of 1hr
Different types of faults in electrical engineering include short circuit, open circuit, ground fault, and overload.
Short circuit: occurs when two conductors come into contact with each other, causing a sudden increase in current flow.
Open circuit: occurs when there is a break in the circuit, preventing current flow.
Ground fault: occurs when a live conductor comes into contact with the ground, causing current to flow t...
posted on 14 Nov 2021
I applied via Referral and was interviewed in Jul 2022. There was 1 interview round.
posted on 17 Feb 2022
I applied via Recruitment Consulltant and was interviewed in Feb 2022. There were 3 interview rounds.
I applied via Approached by Company and was interviewed in Oct 2022. There were 2 interview rounds.
posted on 2 Jun 2022
PSL 2 has stricter requirements than PSL 1. Gas pipelines use PSL 2 pipes.
PSL 2 has higher minimum yield strength and stricter chemical composition requirements than PSL 1
PSL 2 also has non-destructive inspection requirements
Gas pipelines use PSL 2 pipes due to their higher strength and durability
PSL 1 pipes are typically used for low-pressure applications
posted on 14 Aug 2021
I applied via Recruitment Consultant and was interviewed in Jul 2021. There were 4 interview rounds.
Oil and gas offshore operations pose various hazards and require effective evacuation procedures.
Offshore drilling platforms are exposed to risks such as blowouts, fires, explosions, and structural failures.
Hazardous substances like oil, gas, and chemicals can lead to toxic exposures and environmental damage.
Evacuation plans should be in place to ensure the safety of personnel in case of emergencies.
Emergency response ...
If a person is hanging on their body harness at scaffolding, the Lead Safety Officer should take immediate action to rescue them and ensure their safety.
Assess the situation and call for emergency assistance
Attempt to lower the person to the ground using a rescue plan or equipment
Provide first aid or medical attention if necessary
Investigate the incident to determine the cause and prevent future occurrences
Gas detectors are devices used to detect the presence of gases in the environment.
Gas detectors can be categorized into two main types: fixed gas detectors and portable gas detectors.
Fixed gas detectors are permanently installed in a specific location to continuously monitor for the presence of gases.
Portable gas detectors are handheld devices that can be carried around to detect gases in different areas.
Gas detectors ...
To improve backlog of KPI system at work site, prioritize KPIs, automate data collection, and establish regular reporting.
Prioritize KPIs based on their impact on safety and health
Automate data collection to reduce manual errors and save time
Establish regular reporting to track progress and identify areas for improvement
based on 33 reviews
Rating in categories
Process Engineer
18
salaries
| ₹2 L/yr - ₹4.3 L/yr |
Piping Designer
16
salaries
| ₹1.6 L/yr - ₹8.6 L/yr |
Piping Engineer
14
salaries
| ₹2.2 L/yr - ₹4 L/yr |
Instrument Engineer
8
salaries
| ₹3 L/yr - ₹7.2 L/yr |
Electrical Engineer
7
salaries
| ₹3.2 L/yr - ₹4 L/yr |
Larsen & Toubro Limited
Tata Projects
Reliance Infrastructure
GMR Group