Q1. What is the maximum size of tank you have designed or come across your experience?
I have designed a 500,000 gallon tank for a petrochemical plant.
Designed a 500,000 gallon tank for a petrochemical plant
Ensured structural integrity and compliance with industry standards
Considered factors such as material selection, seismic design, and operational requirements
Q2. Whether you will able to design the tank as per API 650?
Yes, I am able to design tanks as per API 650 standards.
I have experience in designing tanks according to API 650 standards
I am familiar with the requirements and guidelines outlined in API 650
I have successfully designed tanks that meet API 650 specifications in the past
Q3. Will you able to design the fire water tank with aluminium roof?
Yes, I am able to design the fire water tank with an aluminium roof.
Yes, I have experience in designing static equipment including fire water tanks.
Aluminium roofs are commonly used in fire water tanks due to their lightweight and corrosion resistance.
Proper insulation and ventilation must be considered when designing an aluminium roof for a fire water tank.
Q4. Will you design the tank as per Aramco standard? Do you have any ARAMCO project experience?
Yes, I will design the tank as per Aramco standard and have experience working on ARAMCO projects.
Yes, I am familiar with Aramco standards and have experience designing tanks to meet their requirements.
I have worked on multiple ARAMCO projects in the past, including designing static equipment such as tanks.
I am well-versed in the specific guidelines and specifications outlined by Aramco for tank design.
Q5. What is the difference between API 650 and API 620
API 650 is for welded steel tanks while API 620 is for large, low pressure storage tanks.
API 650 is for atmospheric storage tanks designed to operate at a pressure of 2.5 psig or less.
API 620 is for low pressure storage tanks with design pressure of up to 15 psig.
API 650 covers the design, construction, operation, and maintenance of welded steel tanks.
API 620 covers the design and construction of large, low pressure storage tanks.
API 650 tanks are typically used for oil, gas,...read more
Q6. What kind of material used for tank design
Materials commonly used for tank design include carbon steel, stainless steel, and aluminum.
Carbon steel is often used for its strength and affordability
Stainless steel is preferred for its corrosion resistance
Aluminum is lightweight and resistant to corrosion
Fiberglass reinforced plastic (FRP) is also used for its corrosion resistance and durability
Q7. How many meters minimum distance to allowed mechanical excavation to use near the underground electrical cable
The minimum distance allowed for mechanical excavation near underground electrical cable is dependent on the voltage of the cable.
The minimum distance should be determined by a competent person
The voltage of the cable should be identified
The distance should be at least equal to the depth of the cable plus 500mm
If the voltage of the cable is higher, the distance should be greater
The excavation should be carried out carefully to avoid damaging the cable
Q8. What is the required minimum height required to use safety harness
The required minimum height to use safety harness is 6 feet or higher.
The minimum height requirement for safety harness varies depending on the industry and jurisdiction.
In general, the minimum height requirement is 6 feet or higher.
This is to ensure that workers are protected from falls and other hazards.
Employers should always follow the guidelines set by their industry and jurisdiction to ensure worker safety.
Q9. 1. What does mean of letter B in ASTM A106 Gr. B. 2.Pwht procedure for Alloy steel P22. 3 Essential variable, supplementary variable and non essential variables for WPS.
Answers to technical questions related to materials and welding procedures.
B in ASTM A106 Gr. B stands for Grade B, indicating the minimum yield strength of the material.
PWHT procedure for Alloy Steel P22 involves heating the material to a specific temperature and holding it for a specific time to relieve residual stresses and improve toughness.
Essential variables for WPS include base material, filler material, welding process, thickness, and joint configuration.