I applied via Naukri.com and was interviewed in Mar 2023. There were 3 interview rounds.
Scan cycle of PLC is the time taken by the PLC to execute a complete cycle of reading inputs, executing the program and updating outputs.
Scan cycle time varies depending on the complexity of the program and the speed of the processor.
It is important to ensure that the scan cycle time is fast enough to meet the requirements of the application.
For example, in a high-speed production line, a fast scan cycle time is necess...
Analog module converts 4-20mA to counts using an ADC and a microcontroller.
Analog-to-digital converter (ADC) measures the current and converts it to a digital value.
Microcontroller processes the digital value and converts it to counts.
Counts are proportional to the current and can be used for control purposes.
Example: A 4-20mA signal can be converted to 0-4095 counts using a 12-bit ADC.
Example: A 4-20mA signal can be c
I applied via Approached by Company and was interviewed in Jan 2024. There were 3 interview rounds.
I applied via Company Website and was interviewed in Aug 2022. There were 3 interview rounds.
I applied via Recruitment Consultant and was interviewed before Oct 2020. There were 4 interview rounds.
Kirloskar Chillers interview questions for popular designations
Top trending discussions
posted on 18 Jan 2025
I applied via Indeed and was interviewed in Dec 2024. There were 3 interview rounds.
PPM of dosing can be calculated by dividing the weight of the solute by the weight of the solution and multiplying by 1,000,000.
Calculate the weight of the solute (in grams)
Calculate the weight of the solution (in grams)
Divide the weight of the solute by the weight of the solution
Multiply the result by 1,000,000 to get the ppm
Aerobic and anaerobic digesters are systems used to break down organic matter. FM ratio is the ratio of food waste to microorganisms in the digester.
Aerobic digester uses oxygen to break down organic matter, while anaerobic digester operates without oxygen.
Aerobic digesters are faster but require more energy, while anaerobic digesters are slower but more energy efficient.
FM ratio (Food to Microorganism ratio) is the ra...
Yes, I have extensive experience in pump and motors as well as electrical components.
I have worked with various types of pumps and motors, including centrifugal pumps and induction motors.
I am familiar with troubleshooting and repairing electrical components such as circuit breakers and control panels.
I have experience in conducting preventive maintenance on pumps and motors to ensure optimal performance.
I have knowled...
I have 5 years of experience in the construction industry with a salary range of $50,000 to $70,000.
5 years of experience in construction industry
Salary range between $50,000 to $70,000
Familiar with industry standards for compensation
Negotiated salary increases based on performance
Received bonuses for meeting project deadlines
Vernier caliper is a precision measuring tool used to measure dimensions with high accuracy.
Vernier calipers have two scales - main scale and vernier scale for precise measurements.
Measurements can be taken in millimeters or inches depending on the caliper.
Commonly used in engineering, manufacturing, and quality control for accurate measurements.
Example: Measuring the diameter of a bolt using a vernier caliper.
The Vernier caliper is used to measure the length, width, and depth of objects with high precision.
Vernier calipers have both metric and imperial scales for accurate measurements.
The main scale on a Vernier caliper is in centimeters or inches, while the Vernier scale allows for more precise readings.
To take a measurement, align the object between the jaws and read the Vernier scale where it lines up with the main scale...
Sleep gauge use is common in quality engineering to monitor sleep patterns and improve overall well-being.
Sleep gauges are used to track sleep duration, quality, and patterns.
Data collected from sleep gauges can be analyzed to identify trends and make adjustments to improve sleep quality.
Examples of sleep gauges include Fitbit, Apple Watch, and specialized sleep tracking devices.
Quality engineers may use sleep gauge da...
posted on 3 Jan 2025
I applied via Company Website and was interviewed in Dec 2024. There were 3 interview rounds.
posted on 30 Dec 2024
I applied via Approached by Company and was interviewed in Nov 2024. There was 1 interview round.
posted on 3 Nov 2024
I applied via Company Website and was interviewed in Oct 2024. There was 1 interview round.
I applied via Campus Placement and was interviewed in Oct 2024. There were 2 interview rounds.
Normal test for releted filed of position
Interview experience
based on 72 reviews
Rating in categories
Service Engineer
30
salaries
| ₹2.2 L/yr - ₹6 L/yr |
Senior Engineer
29
salaries
| ₹3.2 L/yr - ₹7 L/yr |
Senior Sales Engineer
19
salaries
| ₹4 L/yr - ₹8 L/yr |
Assistant Manager
15
salaries
| ₹7 L/yr - ₹12 L/yr |
Sales Manager
7
salaries
| ₹9.5 L/yr - ₹17 L/yr |
Thermax Limited
Voltas
Blue Star
Daikin