Filter interviews by
I applied via Company Website and was interviewed before May 2020. There was 1 interview round.
Top trending discussions
posted on 8 Jul 2024
Structures are framed by designing a skeleton of beams and columns to support the load.
Start by determining the loads the structure will need to support.
Design a skeleton of beams and columns to distribute the load.
Consider factors such as material strength, stability, and aesthetics.
Use software like AutoCAD or Revit to create detailed plans and drawings.
Consult with architects and other engineers to ensure the struct
The value for shape mode represents the most frequently occurring value in a dataset.
Shape mode is the value that appears most frequently in a dataset.
It is used to describe the central tendency of a dataset.
For example, in a dataset of test scores, if the score of 85 appears most frequently, then 85 is the shape mode.
posted on 26 Jun 2024
posted on 24 Dec 2023
I applied via Walk-in and was interviewed in Nov 2023. There were 3 interview rounds.
The IS code for structures in India is IS 456:2000, which covers the general requirements for the design and construction of reinforced concrete structures.
The IS code for structures in India is IS 456:2000
It covers the general requirements for the design and construction of reinforced concrete structures
The code provides guidelines for materials, design, construction, quality control, and maintenance of structures
I applied via Walk-in and was interviewed in Feb 2024. There was 1 interview round.
IS 2911 is the Indian Standard code for design and construction of pile foundations.
IS 2911 is the code for design and construction of pile foundations in India.
It covers various types of piles including driven piles, bored cast-in-situ piles, etc.
The code provides guidelines for the design, materials, construction, and testing of piles.
It ensures the safety and stability of structures supported by piles.
Example: IS 29...
The density of bentonite during piling is typically around 1.0 to 1.2 g/cm^3.
The density of bentonite can vary depending on the specific type and concentration used.
Higher density bentonite is often preferred for better support during piling operations.
Typical range of density for bentonite during piling is 1.0 to 1.2 g/cm^3.
posted on 15 Jun 2024
Shear key is a device used to transfer shear forces between two components in a structure.
Shear keys are typically used in construction joints to prevent sliding between adjacent components.
They are designed to resist horizontal forces and ensure stability.
Shear keys can be found in structures such as bridges, buildings, and dams.
Examples include shear keys in bridge expansion joints to prevent movement between bridge
Columns are vertical structural members that support loads, while beams are horizontal members that transfer loads to columns or walls.
Columns are vertical and primarily support compressive loads.
Beams are horizontal and primarily support bending loads.
Columns are typically taller than they are wide, while beams are typically wider than they are tall.
Examples: In a building, columns support the weight of the floors abo...
posted on 26 Aug 2023
I applied via Recruitment Consulltant and was interviewed in Jul 2023. There were 2 interview rounds.
The bolt to bolt distance depends on the specific design requirements and standards for the structural connection.
The bolt to bolt distance is typically specified in the design drawings or calculations provided by the engineer.
It is important to follow the recommended bolt to bolt distance to ensure the structural integrity of the connection.
The bolt to bolt distance may vary depending on factors such as the size and t...
Edge distance refers to the distance between the edge of a structural member and the center of a hole or fastener.
Edge distance is typically specified in design codes and standards.
It is important to maintain adequate edge distance to prevent failure of the connection.
The required edge distance can vary depending on the type of connection and the loading conditions.
For example, in steel connections, the minimum edge di...
The type of weld used for connecting a column to a base plate is typically a fillet weld.
Fillet welds are commonly used for connecting structural steel components.
The size of the fillet weld is determined based on the forces and stresses the connection will experience.
Proper welding procedures and inspections are essential to ensure the weld's quality and strength.
Column to beam joints are typically connected using various methods such as welding, bolting, or using mechanical connectors.
Common methods for connecting column to beam include welding, bolting, or using mechanical connectors
Welding is a common method where the column and beam are fused together using heat
Bolting involves using bolts to secure the column and beam together
Mechanical connectors such as shear connectors ...
The top moment column to beam top side is typically welded on the compression side of the beam.
Weld the top moment connection on the compression side of the beam for maximum strength.
Ensure proper welding techniques and inspections are followed to maintain structural integrity.
Consider using fillet welds or groove welds depending on the design requirements.
Consult structural engineering codes and standards for specific...
Edge distance of 75mm is required to cover vertical reinforcement in all types of foundations.
Edge distance is important to ensure proper anchorage and structural integrity of the reinforcement.
In this case, a minimum edge distance of 75mm is specified for covering vertical reinforcement in all types of foundations.
Examples of foundations where this requirement applies include spread footings, pile caps, and mat founda
I applied via Recruitment Consulltant and was interviewed in Sep 2021. There were 3 interview rounds.
I applied via campus placement at Birla Institute of Technology and Science (BITS), Pilani and was interviewed in Jul 2024. There were 3 interview rounds.
Social media connecting people
Sfd and bmd diagrams show the variation of shear force and bending moment along the length of a structural member.
SFD (Shear Force Diagram) shows the variation of shear force along the length of a beam or structural member.
BMD (Bending Moment Diagram) shows the variation of bending moment along the length of a beam or structural member.
SFD and BMD are essential for analyzing the internal forces and moments in a structu...
I am a structural engineer with 5 years of experience in designing and analyzing buildings and bridges.
Graduated with a degree in Civil Engineering
Worked on various projects including high-rise buildings and pedestrian bridges
Proficient in software such as AutoCAD and SAP2000
I am open to job locations that offer opportunities for growth and development.
I am willing to relocate for the right job opportunity
I prefer job locations with good transportation options
I am open to both urban and rural locations depending on the job requirements
posted on 28 Dec 2023
Box type structures are commonly used in construction for their strength and durability, often supported by pile foundations with coating for protection against corrosion.
Box type structures are known for their rigid and strong design, providing stability and support for various applications.
Pile foundations are used to transfer the load of the structure to a deeper, more stable soil or rock layer.
Coating on pile found...
based on 1 review
Rating in categories
Junior Engineer
184
salaries
| ₹2 L/yr - ₹4.8 L/yr |
Civil Engineer
156
salaries
| ₹2.2 L/yr - ₹9 L/yr |
Civil Site Engineer
152
salaries
| ₹2 L/yr - ₹6.4 L/yr |
Senior Engineer
146
salaries
| ₹4.5 L/yr - ₹13.5 L/yr |
Engineer
113
salaries
| ₹2.5 L/yr - ₹10 L/yr |
Larsen & Toubro Limited
Hindustan Construction Company
Simplex Infrastructures
IRB Infrastructure