I applied via Approached by Company and was interviewed in May 2024. There was 1 interview round.
Outages for line/switchyard are managed by the load dispatch centre through coordination and communication.
Outages are scheduled in advance to minimize impact on the grid and consumers.
Load dispatch centre coordinates with the concerned authorities to plan and execute the outage.
Alternative arrangements are made to ensure continuity of power supply during the outage.
Regular updates are provided to stakeholders regardin...
Double bus system is important for ensuring redundancy and reliability in power distribution.
Enhances reliability by providing backup in case of failure in one bus
Allows for maintenance work to be carried out on one bus while the other remains operational
Reduces the risk of power outages and downtime
Commonly used in critical infrastructure such as hospitals, data centers, and industrial facilities
I applied via Naukri.com and was interviewed in Apr 2021. There were 4 interview rounds.
The contact resistance of VCB is typically very low.
VCB stands for Vacuum Circuit Breaker.
The contact resistance is the resistance between the contacts of the breaker when it is closed.
The contact resistance of VCB is typically in the range of micro-ohms.
Low contact resistance is important for efficient operation of the breaker.
High contact resistance can cause overheating and damage to the breaker.
The contact resistan...
The resistance value of tripping & closing coil of VCB varies depending on the manufacturer and model.
The resistance value can be found in the manufacturer's manual or datasheet.
It is important to use the correct resistance value to ensure proper functioning of the VCB.
The resistance value may also vary depending on the voltage rating of the VCB.
For example, the ABB VD4 VCB has a tripping coil resistance of 50-60 ohms
The minimum height at which the safety belt should be used is determined by the height of the individual and the specific safety regulations in place.
The minimum height requirement for safety belt usage varies depending on the country and jurisdiction.
In the United States, for example, the minimum height for safety belt usage is typically around 4 feet 9 inches (145 cm).
Other factors such as age, weight, and type of ve...
I applied via Company Website and was interviewed before Jun 2023. There was 1 interview round.
based on 1 interview
Interview experience
based on 8 reviews
Rating in categories
Lead Engineer
255
salaries
| ₹11 L/yr - ₹30.2 L/yr |
Senior Software Engineer
172
salaries
| ₹13.8 L/yr - ₹37 L/yr |
Software Engineer
139
salaries
| ₹7.8 L/yr - ₹22 L/yr |
Engineer
80
salaries
| ₹4.5 L/yr - ₹14.9 L/yr |
Mechanical Engineer
79
salaries
| ₹4.2 L/yr - ₹13.5 L/yr |
Suzlon Group
Adani Group
NTPC
Torrent Power