Types of breakers include circuit breakers, fuse breakers, and earth leakage circuit breakers.
Circuit breakers are designed to protect electrical circuits from damage caused by overload or short circuit.
Fuse breakers use a fuse to interrupt the circuit when an overload occurs.
Earth leakage circuit breakers detect small stray voltages and disconnect the power to prevent electric shock.
Other types include thermal-magneti...
I applied via Company Website and was interviewed in Oct 2023. There were 2 interview rounds.
A transformer is a device that transfers electrical energy between two or more circuits through electromagnetic induction.
Transformers are commonly used to step up or step down voltage levels in electrical systems.
They consist of two coils of wire, known as the primary and secondary coils, wrapped around a core.
The primary coil is connected to the input voltage source, while the secondary coil is connected to the outpu...
Voltage is the difference in electric potential between two points.
Voltage is measured in volts (V).
It represents the potential energy per unit charge.
Voltage is the driving force that pushes electric current through a circuit.
Ohm's Law states that the current flowing through a conductor is directly proportional to the voltage applied across it, and inversely proportional to the resistance of the conductor.
Ohm's Law is represented by the formula V = IR, where V is the voltage, I is the current, and R is the resistance.
It helps in calculating the current flowing through a circuit when the voltage and resistance are known, or determining the r...
I applied via Company Website and was interviewed in Feb 2023. There were 2 interview rounds.
posted on 6 Aug 2023
I applied via Recruitment Consulltant and was interviewed in Feb 2023. There were 3 interview rounds.
Self Introduction and communication English
posted on 27 Jun 2023
posted on 16 Jun 2023
I applied via Walk-in and was interviewed before Jun 2022. There were 3 interview rounds.
A synchronisation panel for DG is used to synchronize multiple generators to ensure they are running in parallel and sharing the load evenly.
Synchronisation panels are used in situations where multiple diesel generators need to be connected in parallel to supply power to a common bus.
The panel monitors the frequency, voltage, and phase angle of each generator and ensures they are synchronized before connecting them to ...
Pulse width in laser refers to the duration of time that a laser beam is emitted.
Pulse width is measured in seconds or milliseconds.
It determines the amount of energy delivered by the laser beam.
Shorter pulse widths are often used for precision cutting or welding.
Longer pulse widths are used for applications like material processing or drilling.
BDV stands for Breakdown Voltage. It is a measure of the dielectric strength of transformer oil.
BDV is the voltage at which the insulation between two conductors breaks down.
It is an important parameter to determine the quality of transformer oil.
BDV is usually measured in kilovolts (kV).
Higher BDV indicates better quality and higher dielectric strength of the oil.
RTCC panel stands for Remote Tap Changing Control panel, used in power transformers to automatically adjust the voltage ratio.
RTCC panel monitors the load and voltage levels of the transformer.
It automatically adjusts the tap changer to maintain the desired voltage ratio.
RTCC panel can be programmed to operate based on specific parameters like load current, temperature, etc.
It helps in optimizing the transformer perfor...
posted on 15 Jul 2021
posted on 18 May 2022
I applied via Company Website and was interviewed before May 2021. There were 2 interview rounds.
Time and distance
based on 3 reviews
Rating in categories
Senior Engineer
538
salaries
| ₹2 L/yr - ₹7.5 L/yr |
Assistant Manager
279
salaries
| ₹5.1 L/yr - ₹15 L/yr |
Executive
237
salaries
| ₹4 L/yr - ₹10 L/yr |
Quality Engineer
228
salaries
| ₹1.1 L/yr - ₹4.8 L/yr |
Senior Production Engineer
150
salaries
| ₹2.6 L/yr - ₹7 L/yr |
Bharat Forge
Samvardhana Motherson Group
Sundaram Clayton
Rane Group