I applied via Company Website and was interviewed in Jan 2022. There were 5 interview rounds.
My concrete work level is excellent and I have experience in various finishing techniques.
I have experience in pouring and leveling concrete for foundations, walls, and slabs.
I am skilled in using various finishing techniques such as troweling, stamping, and staining.
I pay close attention to detail to ensure a smooth and even finish.
I am knowledgeable in the proper curing and sealing of concrete to ensure its longevity...
BBS stands for Bar Bending Schedule, which is a detailed list of reinforcement bars in a structure.
BBS is used in drawing work to ensure the correct amount of reinforcement is used in a structure.
It includes details such as bar diameter, length, shape, and placement.
BBS helps in estimating the amount of steel required for a project and also helps in cost estimation.
It is an important part of the construction process an...
I applied via Naukri.com and was interviewed in Jan 2022. There was 1 interview round.
I applied via Company Website and was interviewed in Jan 2022. There was 1 interview round.
Top trending discussions
Nothing much , rest is basically technical
We have to talk on a subject for log time thats all
Speed control on motors and generators can be achieved through various methods.
For motors, speed control can be achieved by adjusting the voltage, frequency, or the number of poles.
For generators, speed control can be achieved by adjusting the mechanical input or the load connected to the generator.
In motors, variable frequency drives (VFDs) can be used to control the speed by adjusting the frequency of the power suppl...
IDFT controller stands for Inverse Discrete Fourier Transform controller.
IDFT controller is used in signal processing to convert frequency domain signals to time domain signals.
It is the inverse of the Discrete Fourier Transform (DFT) controller.
IDFT controller is commonly used in audio and video processing applications.
It is also used in communication systems to convert frequency domain signals to time domain signals ...
I applied via Naukri.com and was interviewed in Nov 2021. There was 1 interview round.
Impedance is the total opposition to the flow of alternating current in a circuit, while reactance is the opposition to the flow of alternating current caused by capacitance or inductance.
Impedance is a combination of resistance and reactance in a circuit.
Reactance is the opposition to the flow of alternating current caused by capacitance or inductance.
Capacitive reactance is the opposition to the flow of alternating c...
Plant load factor is calculated by dividing the actual energy generated by the maximum possible energy that could have been generated.
Plant load factor = Actual energy generated / Maximum possible energy that could have been generated
Maximum possible energy is calculated by multiplying the rated capacity of the plant with the number of hours in a given time period
Plant load factor is expressed as a percentage
It is used...
I applied via Company Website and was interviewed before May 2021. There was 1 interview round.
Impedance is the measure of opposition to the flow of electric current in a circuit. DGR fundamental refers to the Dielectric Withstand Voltage test.
Impedance is measured in ohms and is the combination of resistance, capacitance, and inductance in a circuit.
DGR fundamental is a test to determine the maximum voltage a material can withstand without breaking down.
Basics of impedance include understanding the relationship...
I applied via Company Website and was interviewed before Jul 2022. There were 3 interview rounds.
The IR resistance of a motor refers to the insulation resistance, which measures the resistance of the insulation material surrounding the motor windings.
IR resistance is measured in ohms and indicates the ability of the insulation to prevent current leakage.
A higher IR resistance value indicates better insulation quality and less risk of electrical faults.
Regular testing of IR resistance is important to ensure the mot...
About power plants activities
based on 2 interviews
1 Interview rounds
based on 10 reviews
Rating in categories
Deputy Manager
222
salaries
| ₹5 L/yr - ₹17.5 L/yr |
Manager
165
salaries
| ₹5.8 L/yr - ₹24.1 L/yr |
Senior Engineer
157
salaries
| ₹4 L/yr - ₹12 L/yr |
Engineer
85
salaries
| ₹3 L/yr - ₹8.4 L/yr |
Senior Manager
63
salaries
| ₹10 L/yr - ₹32 L/yr |
Vestas
Dhoot Transmission
Hitachi Energy
Siemens Energy