I have worked with a variety of equipments including HVAC systems, fire protection systems, plumbing systems, and electrical systems.
HVAC systems
Fire protection systems
Plumbing systems
Electrical systems
I applied via campus placement at Dr Mahalingam College of Engineering & Technology, Coimbatore and was interviewed before Mar 2021. There were 2 interview rounds.
posted on 6 Feb 2025
Pile heads are removed to allow for further construction or to ensure proper load transfer to the foundation.
To prepare for further construction on top of the piles
To ensure proper load transfer to the foundation
To facilitate the installation of pile caps or beams
To adjust the pile length if necessary
There are four deductions of 90 degree angles.
A 90 degree angle is formed when two lines intersect at a right angle.
In a square, all four angles are 90 degrees.
In a rectangle, opposite angles are 90 degrees.
In a right triangle, one angle is always 90 degrees.
Static load test is used to measure the load capacity of a structure under a constant load, while dynamic load test is used to measure the response of a structure to varying loads.
Static load test involves applying a constant load to a structure and measuring its response over time.
Dynamic load test involves applying varying loads to a structure to simulate real-life conditions.
Static load test helps determine the maxi...
The number of tolerance of pile load test depends on the specific project requirements and standards.
The number of tolerance of pile load test can vary based on the project specifications and standards.
Typically, a tolerance of +/- 5% to +/- 10% is considered acceptable for pile load tests.
Some projects may have more stringent tolerance requirements depending on the criticality of the structure.
It is important to refer...
Bentonite has a range density of 17-22 lb/gal and is used in civil engineering for drilling fluid, grouting, and sealing purposes.
Range density of bentonite is typically between 17-22 lb/gal.
Bentonite is used in civil engineering for various purposes such as drilling fluid, grouting, and sealing.
The range density of bentonite is important for determining its effectiveness in different applications.
Higher range density ...
posted on 13 Jan 2025
Easy questions. Take preperation for better performance
Designing a pump foundation involves considering factors like soil conditions, load requirements, and structural stability.
Evaluate soil conditions to determine bearing capacity
Calculate loads from the pump and surrounding equipment
Design foundation to distribute loads evenly and prevent settlement
Consider factors like seismic activity and environmental conditions
Use appropriate materials and construction techniques fo...
Designing pipe racks involves several steps to ensure structural integrity and functionality.
Determine the layout and location of the pipe rack based on piping requirements and site constraints
Calculate the loads and stresses on the pipe rack to ensure it can support the weight of the pipes and withstand external forces
Select appropriate materials and structural components for the pipe rack based on the design requirem...
posted on 27 Jun 2022
I applied via Company Website and was interviewed in Dec 2021. There were 3 interview rounds.
I'm Selected For Road & Infrastructure. So, they an one program for complete road work activities and assign relationships & baseline, etc in Primavera P6 Software.
It was an Nice & Technically improve every inch of our ideas and do fast as possible to get cleared on it.
I applied via Walk-in and was interviewed before Jan 2022. There were 2 interview rounds.
I am unable to provide my previous salary as it is confidential. However, I am expecting a competitive salary based on my qualifications and experience.
My previous salary is confidential and I am unable to disclose it.
I am expecting a salary that is commensurate with my qualifications and experience.
I am open to discussing salary expectations during the negotiation process.
I believe that a competitive salary is importa...
based on 1 interview
Interview experience
based on 1 review
Rating in categories
Safety Officer
36
salaries
| ₹3 L/yr - ₹9.6 L/yr |
Mechanical Supervisor
23
salaries
| ₹4.5 L/yr - ₹14 L/yr |
HSE Supervisor
17
salaries
| ₹5.6 L/yr - ₹20 L/yr |
HSE Officer
16
salaries
| ₹3 L/yr - ₹12.8 L/yr |
Planning Engineer
14
salaries
| ₹10 L/yr - ₹28.1 L/yr |
Larsen & Toubro Limited
TCS
BHEL
Thermax Limited