Filter interviews by
Orifice std refers to standard orifice sizes used in engineering. Types of taps include flange taps, corner taps, and D and D/2 taps.
Orifice std refers to standard sizes of orifices used in flow measurement
Types of taps include flange taps, corner taps, and D and D/2 taps
Flange taps are used for large pipes, corner taps for small pipes, and D and D/2 taps for general applications
Pressure gauge operating range refers to the minimum and maximum pressure values that the gauge can accurately measure.
Pressure gauge operating range is typically specified by the manufacturer.
It is important to ensure that the pressure being measured falls within the gauge's operating range to ensure accurate readings.
For example, a pressure gauge with an operating range of 0-100 psi should not be used to measure pres
Straight length requirements for orifice flow element ensure accurate measurement by allowing flow to stabilize before reaching the element.
Straight length requirements typically range from 10 to 44 pipe diameters upstream and 5 to 22 pipe diameters downstream of the orifice.
These requirements help prevent flow disturbances and ensure accurate measurement of flow rate.
For example, if the pipe diameter is 4 inches, the ...
Top trending discussions
posted on 8 Aug 2021
I applied via Recruitment Consultant and was interviewed in Feb 2020. There were 5 interview rounds.
I applied via LinkedIn and was interviewed in Apr 2023. There were 2 interview rounds.
Various pressure tests are conducted on valves including hydrostatic test, pneumatic test, and cryogenic test.
Hydrostatic test is conducted by filling the valve with water and pressurizing it to a specified pressure to check for leaks.
Pneumatic test involves using air or nitrogen to pressurize the valve and check for leaks or defects.
Cryogenic test is performed at low temperatures to ensure the valve can withstand extr...
Safety considerations in designing piping systems are crucial for preventing accidents and ensuring the integrity of the system.
Ensuring proper material selection to withstand the intended pressure and temperature conditions
Implementing proper support and restraint systems to prevent excessive stress and vibration
Incorporating adequate access points for maintenance and inspection
Following relevant codes and standards s...
posted on 21 Oct 2023
Pushover analysis is a nonlinear static analysis method used to evaluate the seismic performance of structures.
Pushover analysis involves applying a series of lateral loads to a structure and observing its response.
It is used to determine the capacity of a structure to resist seismic forces and identify potential failure modes.
The analysis is based on the assumption that the structure will undergo inelastic behavior du...
To draw bending moment and shear force of a standard portal frame, one needs to analyze the frame's geometry and loading conditions.
Identify the geometry of the portal frame
Determine the loading conditions on the frame
Calculate the reactions at the supports
Draw the shear force and bending moment diagrams
Label the diagrams with values and units
An influence line diagram shows the variation of a response function at a specific point due to a unit load moving along the structure.
Influence lines are used to determine the maximum or minimum response of a structure.
They are commonly used in civil engineering for designing bridges and other structures.
The diagram is drawn by considering the structure as a series of beams and calculating the deflection or reaction a...
I applied via Naukri.com and was interviewed before Nov 2019. There was 1 interview round.
Design parameters for steel structure
Load capacity and distribution
Material strength and durability
Environmental factors such as wind and seismic activity
Connection details and joint design
Fire resistance and protection measures
I have 5 years of exposure to STAAD software.
I have used STAAD for various structural analysis and design projects.
I am proficient in using STAAD for modeling, analysis, and design of steel and concrete structures.
I have experience in using STAAD for seismic analysis and design of structures.
I have also used STAAD for foundation design and analysis.
I keep myself updated with the latest versions and features of STAAD so
I applied via Referral and was interviewed in Oct 2022. There were 2 interview rounds.
I applied via Company Website and was interviewed before Jan 2022. There were 3 interview rounds.
based on 1 interview
Interview experience
based on 7 reviews
Rating in categories
Electrical Engineer
92
salaries
| ₹4.8 L/yr - ₹10.1 L/yr |
Electrical Designer
54
salaries
| ₹4 L/yr - ₹13.8 L/yr |
Senior Associate Engineer
53
salaries
| ₹7.5 L/yr - ₹12 L/yr |
Project Control Engineer
50
salaries
| ₹5.5 L/yr - ₹10 L/yr |
Senior Electrical Engineer
36
salaries
| ₹8 L/yr - ₹20.1 L/yr |
AECOM
AtkinsRealis
Saipem
Nasser S. Al Hajri Corporation