Favourable zone in RCC refers to the region of a reinforced concrete member where the concrete is in compression and the steel is in tension.
Favourable zone is the area where the concrete is able to resist compressive forces effectively.
It is typically located at the top of a beam or slab, where the bending moment is highest.
In this zone, the steel reinforcement helps to resist tensile forces, while the concrete resist...
Lap length is the length of overlap between two reinforcing bars in a concrete structure to ensure proper transfer of loads.
Lap length is important for ensuring the continuity of reinforcement in concrete structures.
It is typically specified in building codes and design standards.
The lap length required depends on factors such as the diameter of the bars, concrete strength, and design loads.
For example, in a beam, the ...
Lapping in reinforcement involves overlapping two reinforcement bars to ensure continuity and strength in the structure.
Lapping is commonly used in construction to connect two reinforcement bars together.
The length of the lap varies depending on the design requirements and the type of reinforcement used.
Proper lapping ensures that the load is transferred effectively between the bars.
Examples of lapping include lap spli
Bearings in bridges help distribute loads and allow for movement due to temperature changes and settlement.
Bearings help distribute the loads from the superstructure to the substructure of the bridge.
They allow for movement of the bridge deck due to temperature changes, wind forces, and settlement of the foundation.
Bearings help reduce stress on the bridge components and prevent damage.
Common types of bearings used in ...
Types of expansion joints include slip joints, bellows joints, and modular joints.
Slip joints allow for movement in one direction only
Bellows joints accommodate movement in multiple directions
Modular joints are made up of separate components that can be replaced individually
Top trending discussions
posted on 15 Feb 2025
I applied via Referral and was interviewed before Jul 2023. There was 1 interview round.
I designed a critical high-rise building with complex structural requirements.
Implemented innovative seismic design techniques to ensure structural stability
Utilized advanced modeling software to analyze load distribution and optimize structural components
Collaborated with architects and construction teams to integrate design elements seamlessly
Incorporated sustainable materials and practices to enhance the building's
I applied via LinkedIn and was interviewed in Feb 2024. There were 2 interview rounds.
Static analysis deals with loads that do not change over time, while dynamic analysis considers loads that vary with time.
Static analysis is used to determine the effects of loads that do not change over time, such as dead loads and live loads.
Dynamic analysis considers loads that vary with time, such as wind loads, seismic loads, and vibrations.
Static analysis is simpler and less computationally intensive compared to ...
Spectral fatigue analysis is performed by calculating the stress response of a structure to dynamic loads over a range of frequencies.
Determine the dynamic loads acting on the structure
Calculate the stress response of the structure using spectral methods
Analyze the stress response at different frequencies to assess fatigue damage
Consider factors such as material properties, load history, and environmental conditions
Use...
I prioritize transparency, disclose the conflict, and recuse myself if necessary.
Prioritize transparency and disclose the conflict to all parties involved
Evaluate the situation and determine if recusal is necessary
Seek guidance from a supervisor or ethics committee if unsure how to proceed
My notice period is currently one month.
Notice period is one month
I am required to give one month notice before leaving my current position
I can start a new position after one month
I applied via Referral and was interviewed in Dec 2023. There was 1 interview round.
Fixed connection does not allow rotation at the base plate, while pinned connection allows rotation.
Fixed connection is rigid and does not allow rotation at the base plate.
Pinned connection allows rotation at the base plate.
Fixed connection provides more stability and resistance to lateral forces.
Pinned connection is more flexible and allows for some movement.
Examples: Fixed connection is commonly used in high-rise bui...
The rise is the vertical distance between two consecutive steps, while the tread is the horizontal distance.
The rise is typically around 7-8 inches, while the tread is usually around 10-11 inches.
The rise and tread dimensions are important for ensuring safe and comfortable stair design.
Building codes often dictate the minimum and maximum rise and tread dimensions for safety reasons.
Pitch distance in bolt refers to the distance between the centers of adjacent bolts in a bolted connection.
Pitch distance is typically measured from the center of one bolt to the center of the next bolt in a row.
It is important to maintain consistent pitch distances to ensure proper load distribution and structural integrity.
For example, in a bolted connection with a pitch distance of 2 inches, the centers of adjacent
To create a pipe rack section on both directions.
Identify the location and dimensions for the pipe rack section
Consider the load requirements and support structures
Design the pipe rack section using appropriate materials and connections
Ensure proper spacing and alignment for pipes in both directions
Yes, I have extensive experience with basements and below ground structures.
I have designed and analyzed numerous basements for residential and commercial buildings.
I am familiar with waterproofing techniques and soil mechanics related to below ground structures.
I have experience with retaining walls, foundations, and underground parking structures.
I have worked on projects involving deep excavations and shoring system...
I applied via LinkedIn and was interviewed in Oct 2023. There was 1 interview round.
Earthquake loads are calculated using seismic design codes and formulas based on the seismic hazard of the region.
Determine the seismic hazard of the region using historical data and seismic maps
Select a seismic design code such as ASCE 7 or Eurocode 8
Calculate the seismic base shear using the formula V = CsW
Distribute the seismic base shear to the structure using the appropriate load combinations
Consider the effects o...
I applied via campus placement at National Institute of Technology (NIT), Warangal and was interviewed before May 2023. There were 3 interview rounds.
Aptitude+ Technical MCQ test
BMD and SFD diagrams show internal forces in a structure, like bending moment and shear force.
BMD diagram displays variation of bending moment along the length of a beam or frame.
SFD diagram shows variation of shear force along the length of a beam or frame.
In continuous beams, BMD and SFD diagrams help in analyzing internal forces at different supports and sections.
Portal frames have different loading conditions which...
Plastic method of design is a structural engineering approach that considers the redistribution of internal forces to achieve a more efficient design.
Plastic method allows for redistribution of internal forces beyond the elastic limit of the material.
It is based on the concept of plastic hinges forming in the structure to dissipate energy.
Design is based on achieving a collapse mechanism that is ductile and predictable...
I applied via Referral
posted on 6 Aug 2022
I applied via Naukri.com and was interviewed in Feb 2022. There were 3 interview rounds.
based on 1 interview
Interview experience
based on 5 reviews
Rating in categories
Senior Engineer
133
salaries
| ₹4.2 L/yr - ₹11.1 L/yr |
Assistant Manager
126
salaries
| ₹5.2 L/yr - ₹15.5 L/yr |
Structural Engineer
94
salaries
| ₹3 L/yr - ₹7.8 L/yr |
Site Engineer
91
salaries
| ₹3 L/yr - ₹7 L/yr |
Deputy Manager
83
salaries
| ₹7 L/yr - ₹18.5 L/yr |
Larsen & Toubro Limited
GMR Group
Reliance Infrastructure
IRB Infrastructure