I applied via Company Website and was interviewed in Jun 2024. There was 1 interview round.
I have extensive experience working with wind turbines, including maintenance, troubleshooting, and repairs.
Performed regular maintenance checks on wind turbines to ensure optimal performance
Troubleshooted and repaired mechanical and electrical issues as needed
Worked with a team to install new wind turbines and ensure they were functioning correctly
Utilized specialized tools and equipment to perform tasks safely and ef
Site incharge oversees operations, manages resources, ensures safety, and coordinates with stakeholders.
Managing day-to-day operations at the site
Supervising and coordinating with on-site staff and contractors
Ensuring compliance with safety regulations and protocols
Managing resources effectively to meet project deadlines
Communicating with clients, vendors, and other stakeholders
Troubleshooting technical issues and prov...
I am drawn to this company for its innovative technology, commitment to customer satisfaction, and opportunities for professional growth.
The company's reputation for cutting-edge technology aligns with my passion for engineering and problem-solving.
I admire the strong focus on customer service, which is crucial in a service engineer role; I believe in building lasting relationships with clients.
The opportunity for cont...
I possess extensive technical knowledge in electronics, troubleshooting, and customer service, essential for a Service Engineer role.
Proficient in diagnosing and repairing electronic devices, such as circuit boards and sensors.
Experience with software tools for system diagnostics, like multimeters and oscilloscopes.
Strong understanding of mechanical systems, enabling effective troubleshooting of equipment.
Knowledge of ...
Top trending discussions
I applied via Walk-in and was interviewed before Sep 2020. There were 3 interview rounds.
Increasing business can be achieved through various strategies.
Identify target audience and tailor marketing efforts accordingly
Offer promotions and discounts to attract new customers
Improve customer service to retain existing customers
Expand product or service offerings to attract a wider audience
Collaborate with other businesses to reach new markets
posted on 23 Feb 2024
Plant load factor is a measure of the actual output of a power plant compared to its maximum possible output.
Plant load factor is calculated by dividing the actual energy generated by the plant over a specific period by the maximum possible energy that could have been generated during the same period.
It is expressed as a percentage and indicates how efficiently a power plant is being utilized.
A high plant load factor i...
Machine availability is the percentage of time a machine is able to be used for its intended purpose.
Machine availability is calculated by dividing the total operating time by the total time in a given period, then multiplying by 100.
For example, if a machine operates for 800 hours in a month and there are 1000 total possible operating hours, the availability would be 80%.
Factors like downtime, maintenance, and repairs
I applied via Naukri.com and was interviewed before May 2022. There were 2 interview rounds.
A line diagram of a wind turbine generator (WTG) shows the flow of energy from wind to electricity.
The diagram typically includes the rotor blades, gearbox, generator, and power electronics
The blades capture wind energy and turn the rotor, which drives the gearbox
The gearbox increases the rotational speed and sends it to the generator
The generator converts the rotational energy into electrical energy
The power electroni...
DFIG converters are used in wind turbines to convert variable frequency AC power to DC power and back to AC power.
DFIG stands for Doubly Fed Induction Generator
The converter consists of two back-to-back voltage source converters
One converter controls the rotor current and the other controls the grid current
The rotor current is controlled to maintain a constant torque on the turbine
The grid current is controlled to main...
IGBT stands for Insulated Gate Bipolar Transistor, a semiconductor device used for switching applications in power electronics.
IGBT is a type of transistor that combines the high efficiency of a bipolar junction transistor (BJT) with the high input impedance of a MOSFET.
It is commonly used in applications such as motor drives, inverters, and power supplies.
IGBTs are used for high power applications due to their ability...
posted on 24 Mar 2025
I applied via Walk-in and was interviewed in Feb 2021. There were 3 interview rounds.
To troubleshoot inverters, SCBs, transformers, and breakers, follow these pointers:
Check for loose connections and wiring
Inspect for physical damage or wear and tear
Use a multimeter to test voltage and current
Check for proper grounding
Refer to manufacturer's manual for specific troubleshooting steps
based on 2 interviews
Interview experience
based on 42 reviews
Rating in categories
Engineer
268
salaries
| ₹3 L/yr - ₹12 L/yr |
Senior Engineer
199
salaries
| ₹5 L/yr - ₹14 L/yr |
Lead Engineer
187
salaries
| ₹8.2 L/yr - ₹28.6 L/yr |
Assistant Lead Engineer
181
salaries
| ₹8.2 L/yr - ₹19 L/yr |
Buyer
108
salaries
| ₹3.2 L/yr - ₹8.8 L/yr |
Adani Power
Adani Group
NTPC
Tata Power