Filter interviews by
I applied via Naukri.com and was interviewed in May 2024. There were 7 interview rounds.
Slump of pile concrete on site refers to the consistency or workability of the concrete mixture used for pile construction.
Slump is a measure of the consistency of concrete before it sets. It is typically measured in millimeters.
A higher slump indicates a more workable concrete mixture, while a lower slump indicates a stiffer mixture.
Slump tests should be conducted regularly on site to ensure the concrete meets the req...
Pre-tensioning is done before casting concrete while post-tensioning is done after casting concrete.
Pre-tensioning involves tensioning the tendons before the concrete is poured, creating compression in the concrete once it hardens.
Post-tensioning involves tensioning the tendons after the concrete has hardened, allowing for greater control over the amount of tension applied.
Pre-tensioning is typically used in precast co...
Minimum diameter of reinforcement used in a culvert is typically 10mm.
Minimum diameter of reinforcement in culverts is usually 10mm
Reinforcement diameter may vary based on design requirements
Larger diameter reinforcement may be used for higher load capacities
Types of grade cement include OPC, PPC, PSC, and SRC.
Ordinary Portland Cement (OPC) is the most commonly used type of cement.
Portland Pozzolana Cement (PPC) contains pozzolanic materials like fly ash.
Portland Slag Cement (PSC) contains granulated blast furnace slag.
Sulphate Resistant Cement (SRC) is used in construction exposed to sulphates.
Water-cement ratio (w/c) of concrete for pile is typically between 0.4 to 0.6.
Water-cement ratio affects the strength and durability of concrete.
Lower w/c ratio results in higher strength but may be difficult to work with.
Higher w/c ratio may lead to lower strength and durability.
For piles, a w/c ratio of 0.45 to 0.55 is commonly used.
Proper curing is essential to achieve desired strength and durability.
Top trending discussions
I applied via Naukri.com and was interviewed in May 2024. There were 2 interview rounds.
Under and over reinforcement in beams and columns refers to the amount of reinforcement provided in relation to the required strength of the structure.
Under reinforcement occurs when the amount of reinforcement provided is less than what is required for the structure to carry the design loads.
Over reinforcement occurs when the amount of reinforcement provided is more than what is required for the structure, leading to ...
NDT tests of members are done to ensure structural integrity and safety.
NDT tests are non-destructive tests used to evaluate the properties of a material, component, or system without causing damage.
These tests help in detecting defects such as cracks, voids, and discontinuities that may compromise the structural integrity of the members.
By conducting NDT tests, engineers can ensure the safety and reliability of struct...
I applied via Approached by Company and was interviewed in Jul 2024. There was 1 interview round.
I applied via Walk-in and was interviewed before Aug 2023. There was 1 interview round.
I applied via Recruitment Consulltant and was interviewed in Mar 2023. There were 2 interview rounds.
I am currently working at a construction site in downtown city.
Construction site in downtown city
Working on a high-rise building project
Coordinating with architects, contractors, and workers
Ensuring adherence to safety regulations and project timelines
posted on 19 Jul 2022
I applied via Company Website and was interviewed in Jun 2022. There were 2 interview rounds.
I applied via Recruitment Consulltant
The SI unit of inductance is Henry (H).
Inductance is the property of an electrical circuit that opposes a change in current.
It is measured in Henry (H) and is named after American scientist Joseph Henry.
Inductance is used in various electrical components such as transformers, inductors, and motors.
The symbol for inductance is L and it is measured in units of Henry per meter squared (H/m^2).
Highmast and street lights , Towers , Control panel trouble shoot
Aptitude test like mathematics question ,reasoning & our department like mechanical engineer
Round was quite easy, for mechanical they had turbo machinery and heat transfer questions and basic SOM,TOM,MD,MF
Lifts work on the principle of pulleys and counterweights while ACs work on the principle of refrigeration.
Lifts use a motor to move a counterweight that balances the weight of the lift car and its occupants.
ACs use a compressor to compress and expand refrigerant gas to absorb and release heat.
Types of ACs include window ACs, split ACs, central ACs, and portable ACs.
Window ACs are mounted on windows and cool a single r...
I applied via Referral and was interviewed in Sep 2023. There were 2 interview rounds.
Interview experience
based on 1 review
Rating in categories
Site Engineer
9
salaries
| ₹2.5 L/yr - ₹5.4 L/yr |
Assistant Engineer
4
salaries
| ₹3.2 L/yr - ₹3.8 L/yr |
Senior Quantity Surveyor
4
salaries
| ₹6.5 L/yr - ₹7.7 L/yr |
Civil Site Engineer
4
salaries
| ₹2.4 L/yr - ₹3.6 L/yr |
Channel Sales Manager
4
salaries
| ₹9.1 L/yr - ₹10 L/yr |
JLL
CBRE
NoBroker
Square Yards