i
Transasia Bio-Medicals
Filter interviews by
Top trending discussions
posted on 18 Oct 2024
The fill volume formula calculates the volume of liquid or gas that can be held in a container.
The fill volume formula is typically calculated by multiplying the area of the base of the container by its height.
For example, the fill volume of a cylindrical tank can be calculated using the formula V = πr^2h, where r is the radius of the base and h is the height of the tank.
Different shapes of containers will have differe...
Dynamic pass box allows for continuous transfer of materials while static pass box requires manual transfer.
Dynamic pass box has a conveyor belt for continuous transfer of materials.
Static pass box requires manual transfer of materials.
Dynamic pass box is more efficient for high volume transfer.
Static pass box is suitable for low volume transfer or when contamination risk is high.
Examples: Pharmaceutical industry uses ...
Clean room areas are classified based on the level of cleanliness required for the specific activities performed within them.
Clean room areas are classified using ISO standards, with Class 1 being the cleanest and Class 9 being the least clean.
The classification is based on the maximum allowable concentration of particles per cubic meter of air.
Examples of clean room areas include semiconductor manufacturing facilities...
AMV guidelines and method validation parameters are essential for ensuring the accuracy and reliability of analytical methods.
AMV guidelines provide a framework for validating analytical methods to ensure they meet the required standards.
Method validation parameters include specificity, accuracy, precision, linearity, range, and robustness.
Examples of method validation parameters include determining the limit of detect...
LOD and LOQ values are determined based on signal-to-noise ratio and standard deviation of the response.
LOD (Limit of Detection) is the lowest concentration of an analyte that can be reliably detected but not necessarily quantified.
LOQ (Limit of Quantification) is the lowest concentration of an analyte that can be reliably measured and quantified.
LOD is typically determined as 3 times the standard deviation of the blan...
I applied via Company Website and was interviewed in Jul 2024. There was 1 interview round.
Cognitive test and questions
posted on 23 May 2024
I applied via Naukri.com and was interviewed in Apr 2024. There was 1 interview round.
posted on 20 Jun 2024
About HR related assignment
posted on 18 Jul 2024
I applied via Referral and was interviewed in Dec 2023. There was 1 interview round.
based on 1 interview
Interview experience
Assistant Manager
70
salaries
| ₹5.8 L/yr - ₹14.5 L/yr |
Service Engineer
68
salaries
| ₹2.4 L/yr - ₹6.2 L/yr |
Area Sales Manager
66
salaries
| ₹6.2 L/yr - ₹11.6 L/yr |
Sales Executive
49
salaries
| ₹3 L/yr - ₹5.8 L/yr |
Senior Service Engineer
47
salaries
| ₹5 L/yr - ₹9.1 L/yr |
Trivitron Healthcare
Agappe Diagnostics
Span Diagnostics
J Mitra And Co