Q1. What do you understand by steady state stability in power system?
Steady state stability refers to the ability of a power system to maintain a stable operating condition under normal operating conditions.
Steady state stability is important for ensuring the reliability of the power system.
It is affected by factors such as load demand, generator output, and transmission line capacity.
If the power system is not in steady state stability, it can lead to voltage instability, frequency instability, and even blackouts.
Steady state stability can be...read more
Q2. What are the reading available in the commercial meter, advantage of smart meter.
Commercial meters measure energy consumption, while smart meters provide real-time data and enable remote monitoring.
Commercial meters measure energy consumption in kilowatt-hours (kWh).
Smart meters provide real-time data on energy usage and enable remote monitoring.
Smart meters can also detect power outages and help utilities quickly restore service.
Smart meters can provide detailed information on energy usage patterns, allowing consumers to make more informed decisions abou...read more
Q3. What first 5 things you will notice if we send you on a inspection of a distribution network?
The first 5 things I will notice during an inspection of a distribution network
Overall layout and organization of the distribution center
Condition of equipment and machinery used in the distribution process
Inventory levels and storage capacity
Safety measures and protocols in place
Efficiency of the distribution process and any bottlenecks
Q4. What are different types of losses in a LT Network?
Different types of losses in a LT Network include copper losses, iron losses, and stray losses.
Copper losses: Occur due to resistance in the conductors, leading to heat dissipation.
Iron losses: Result from hysteresis and eddy current losses in the transformer core.
Stray losses: Arise from leakage flux and other inefficiencies in the network.
Examples: A transformer experiencing iron losses will heat up due to hysteresis and eddy currents.
Examples: Copper losses can be reduced ...read more
Q5. Explain one and half breaker scheme
One and a half breaker scheme is a protection scheme used in power systems to provide selective tripping of faulty sections.
It involves using one full circuit breaker and one half circuit breaker to protect a section of the power system.
The full circuit breaker is used to protect the main section while the half circuit breaker is used to protect the adjacent section.
If a fault occurs in the adjacent section, the half circuit breaker trips and isolates the faulty section while...read more
Q6. Protection in distrubation system
Protection measures are necessary to ensure safety and reliability of distribution systems.
Protection devices such as fuses, circuit breakers, and relays are used to detect and isolate faults.
Grounding systems are used to protect against electrical shock and lightning strikes.
Backup power sources such as generators and batteries are used to ensure continuity of service.
Regular maintenance and testing of protection systems is essential to ensure their effectiveness.
Protection ...read more