i
The BIM Engineers
Filter interviews by
I applied via Walk-in and was interviewed in Aug 2023. There were 2 interview rounds.
I applied via Walk-in and was interviewed in Aug 2023. There was 1 interview round.
I applied via LinkedIn and was interviewed before May 2023. There was 1 interview round.
The BIM Engineers interview questions for designations
I applied via Naukri.com and was interviewed in Nov 2021. There was 1 interview round.
Section box is used to isolate a portion of the model for viewing/editing. Scope box is used to define the boundary of a view.
Section box is used to cut a section of the model for better visibility and editing.
Scope box is used to define the boundary of a view and control the visibility of elements outside the boundary.
Section box is used in 3D views while scope box is used in plan, section, elevation views.
Section box...
Linking CAD files in Revit provides better control and flexibility.
Linked CAD files can be updated without affecting the Revit model.
Linked CAD files can be managed separately from the Revit model.
Linked CAD files can be controlled with visibility settings.
Importing CAD files can increase file size and slow down performance.
Linking CAD files allows for better collaboration with external consultants.
Linked CAD files can
There are three types of Revit file linking process: Overlay, Attachment, and Imported CAD. We use it to link external files to our Revit project.
Overlay: used to display the linked file on top of the host model
Attachment: used to attach the linked file to the host model
Imported CAD: used to import CAD files into Revit
We use linking process to collaborate with other disciplines, to reference external files, and to crea...
Top trending discussions
I applied via Walk-in and was interviewed before Feb 2022. There were 3 interview rounds.
They shared a drawing to create the bim model
posted on 25 Nov 2024
I applied via Campus Placement and was interviewed in Oct 2024. There was 1 interview round.
I joined the company because of its innovative projects and collaborative work environment.
Opportunity to work on cutting-edge projects
Collaborative work environment
Company's reputation in the industry
Career growth opportunities
Orifice std refers to standard orifice sizes used in engineering. Types of taps include flange taps, corner taps, and D and D/2 taps.
Orifice std refers to standard sizes of orifices used in flow measurement
Types of taps include flange taps, corner taps, and D and D/2 taps
Flange taps are used for large pipes, corner taps for small pipes, and D and D/2 taps for general applications
Pressure gauge operating range refers to the minimum and maximum pressure values that the gauge can accurately measure.
Pressure gauge operating range is typically specified by the manufacturer.
It is important to ensure that the pressure being measured falls within the gauge's operating range to ensure accurate readings.
For example, a pressure gauge with an operating range of 0-100 psi should not be used to measure pres
Straight length requirements for orifice flow element ensure accurate measurement by allowing flow to stabilize before reaching the element.
Straight length requirements typically range from 10 to 44 pipe diameters upstream and 5 to 22 pipe diameters downstream of the orifice.
These requirements help prevent flow disturbances and ensure accurate measurement of flow rate.
For example, if the pipe diameter is 4 inches, the ...
based on 10 interviews
1 Interview rounds
based on 30 reviews
Rating in categories
BIM Engineer
193
salaries
| ₹2.5 L/yr - ₹7.2 L/yr |
BIM Architect
103
salaries
| ₹3 L/yr - ₹7.6 L/yr |
MEP Bim Engineer
55
salaries
| ₹4 L/yr - ₹7.2 L/yr |
Senior BIM Engineer
46
salaries
| ₹4.3 L/yr - ₹10 L/yr |
BIM Modeller
44
salaries
| ₹3 L/yr - ₹7.3 L/yr |
AECOM
TCE
L&T Technology Services
Cyient