I applied via Naukri.com and was interviewed before May 2022. There were 3 interview rounds.
I applied via Campus Placement and was interviewed before Jan 2023. There were 2 interview rounds.
Aptitudetest based on Quantitative Assessmeat, few DI BASED QUESTIONS
I applied via Newspaper Ad and was interviewed in Dec 2021. There were 3 interview rounds.
Aptitude and technical and english test
I applied via Internshala and was interviewed before Oct 2022. There were 2 interview rounds.
Tata Power interview questions for popular designations
I applied via Approached by Company and was interviewed before Sep 2022. There were 3 interview rounds.
Very tough and technical
Get interview-ready with Top Tata Power Interview Questions
I applied via Walk-in and was interviewed in Mar 2022. There were 2 interview rounds.
I applied via Campus Placement and was interviewed before Mar 2022. There were 3 interview rounds.
Aptitude test was based on general knowledge which can be solved with practice easily
I applied via Campus Placement and was interviewed in Nov 2021. There was 1 interview round.
The contact resistance of VCB is typically very low.
VCB stands for Vacuum Circuit Breaker.
The contact resistance is the resistance between the contacts of the breaker when it is closed.
The contact resistance of VCB is typically in the range of micro-ohms.
Low contact resistance is important for efficient operation of the breaker.
High contact resistance can cause overheating and damage to the breaker.
The contact resistan...
The resistance value of tripping & closing coil of VCB varies depending on the manufacturer and model.
The resistance value can be found in the manufacturer's manual or datasheet.
It is important to use the correct resistance value to ensure proper functioning of the VCB.
The resistance value may also vary depending on the voltage rating of the VCB.
For example, the ABB VD4 VCB has a tripping coil resistance of 50-60 ohms
The minimum height at which the safety belt should be used is determined by the height of the individual and the specific safety regulations in place.
The minimum height requirement for safety belt usage varies depending on the country and jurisdiction.
In the United States, for example, the minimum height for safety belt usage is typically around 4 feet 9 inches (145 cm).
Other factors such as age, weight, and type of ve...
Magnetic core balance test is done to measure the balance of magnetic cores in a transformer.
The test is performed by injecting a current into one winding of the transformer and measuring the voltage induced in the other winding.
The test is repeated for each winding of the transformer.
The results are compared to determine if the magnetic cores are balanced.
If the magnetic cores are not balanced, it can lead to increase...
Power factor is a measure of how effectively electrical power is being used and it affects the efficiency of electrical systems.
Power factor is the ratio of real power (kW) to apparent power (kVA) in an electrical system.
It indicates how much of the total power is being used for useful work.
A power factor of 1 means all the power is being used effectively, while a power factor less than 1 indicates inefficiency.
Low pow...
Active power is the actual power consumed by a device or system.
Active power is measured in watts (W).
It is the power that is actually doing the work.
It is the product of voltage and current in an AC circuit.
It is also known as real power.
For example, a 100W light bulb consumes 100W of active power.
Top trending discussions
The duration of Tata Power interview process can vary, but typically it takes about less than 2 weeks to complete.
based on 170 interviews
Interview experience
based on 1.4k reviews
Rating in categories
Lead Engineer
745
salaries
| ₹0 L/yr - ₹0 L/yr |
Team Lead
222
salaries
| ₹0 L/yr - ₹0 L/yr |
Assistant Manager
182
salaries
| ₹0 L/yr - ₹0 L/yr |
Manager
179
salaries
| ₹0 L/yr - ₹0 L/yr |
Graduate Engineer Trainee (Get)
130
salaries
| ₹0 L/yr - ₹0 L/yr |
Adani Power
NTPC
Reliance Power
JSW Energy