Detectors in HPLC include UV-Vis, fluorescence, refractive index, and mass spectrometry.
UV-Vis detector measures absorbance of UV or visible light by the analyte.
Fluorescence detector measures fluorescence emitted by the analyte when excited by light.
Refractive index detector measures changes in refractive index of the eluent.
Mass spectrometry detector measures mass-to-charge ratio of ions produced from analyte.
UV and FTIR principles are analytical techniques used for identifying and analyzing chemical compounds based on their absorption of ultraviolet-visible light and infrared radiation, respectively.
UV spectroscopy involves measuring the absorption of UV or visible light by a sample to determine its concentration or purity.
FTIR spectroscopy measures the absorption of infrared radiation by a sample to identify functional gr...
posted on 1 Nov 2023
I applied via Walk-in and was interviewed in Oct 2023. There were 2 interview rounds.
Precautions for UV analysis include wearing protective gear, calibrating equipment, and avoiding contamination.
Wear appropriate protective gear such as gloves, goggles, and lab coat to prevent exposure to UV radiation.
Calibrate UV equipment regularly to ensure accurate readings.
Avoid contamination by cleaning all surfaces and equipment thoroughly before starting the analysis.
Handle UV-sensitive samples carefully to pre...
KBr is used in IR analysis to prepare samples for analysis by creating a transparent pellet.
KBr is used as a diluent to mix with the sample being analyzed
It helps to create a transparent pellet which allows for accurate analysis of the sample
KBr has a wide transmission range in the infrared spectrum
It is chemically inert and does not interfere with the sample being analyzed
I applied via Campus Placement and was interviewed before Nov 2020. There were 3 interview rounds.
I applied via Walk-in and was interviewed before Jan 2019. There were 3 interview rounds.
I applied via Naukri.com and was interviewed before Jun 2021. There were 2 interview rounds.
I applied via Walk-in and was interviewed in Oct 2020. There were 3 interview rounds.
I applied via Naukri.com and was interviewed before Aug 2020. There were 4 interview rounds.
Flows of Validation refers to the process of verifying and confirming the accuracy and integrity of data or information.
Flows of Validation involve checking data for errors, inconsistencies, and completeness.
Validation can be done through various methods such as data sampling, cross-referencing, and data reconciliation.
Examples of validation processes include validating financial transactions, validating user input in ...
The mean of Direct impact and No impact systems is undefined.
Direct impact and No impact systems are not comparable in terms of impact.
Direct impact systems have a significant impact on the organization or process, while No impact systems have no impact.
Therefore, calculating the mean of these two types of systems is not meaningful.
It is important to evaluate the impact of each system separately and make decisions acco
The impact of set values of parameters on product quality
Set values of parameters can have a direct impact on product quality
If the set values do not affect the product quality, it is considered non-impactful
Examples of parameters that can affect product quality include temperature, pressure, and time
Proper calibration and monitoring of parameters can ensure consistent product quality
Risk assessment is the process of identifying, analyzing and evaluating potential risks to an organization or project.
Helps in identifying potential risks and their impact
Enables prioritization of risks based on their severity
Assists in developing strategies to mitigate or manage risks
Provides a framework for decision-making and resource allocation
Examples: financial risk assessment, cybersecurity risk assessment, proj
I applied via Campus Placement and was interviewed before Aug 2021. There were 2 interview rounds.
GMP and do discuss all its related problems and compliance
I applied via Naukri.com and was interviewed in Jul 2020. There were 3 interview rounds.
I applied via Approached by Company and was interviewed before Dec 2021. There were 3 interview rounds.
I was the Senior Producer at XYZ Productions.
Position: Senior Producer
Organogram: [Your position] - 2 lines above and 2 lines below
Example: Senior Producer - 2 lines above: Executive Producer, Line Producer; 2 lines below: Associate Producer, Production Coordinator
The number of classes in a sterile area varies depending on the industry and regulations.
The number of classes in a sterile area can range from 1 to 100+.
In the pharmaceutical industry, there are typically four classes of sterile areas: Class A, Class B, Class C, and Class D.
Each class has different requirements for air cleanliness and particle count.
For example, Class A areas have the strictest requirements and are us...
HVAC stands for Heating, Ventilation, and Air Conditioning. CFU stands for Colony Forming Unit. CFM stands for Cubic Feet per Minute. ACPH stands for Air Changes per Hour. HEPA stands for High Efficiency Particulate Air. LAF stands for Laminar Air Flow.
HVAC - system for controlling temperature, humidity, and air quality in buildings
CFU - unit of measurement for the number of viable microorganisms in a sample
CFM - unit ...
based on 1 interview
Interview experience
based on 6 reviews
Rating in categories
Executive
816
salaries
| ₹3 L/yr - ₹6.2 L/yr |
Senior Executive
471
salaries
| ₹3.8 L/yr - ₹10.1 L/yr |
Team Lead
185
salaries
| ₹6 L/yr - ₹16 L/yr |
Senior Team Leader
93
salaries
| ₹11.4 L/yr - ₹20.9 L/yr |
Assistant Manager
69
salaries
| ₹7.5 L/yr - ₹14 L/yr |
Hetero
Abbott
Micro Labs
Ajanta Pharma