i
Sterling & Wilson
Filter interviews by
I applied via Recruitment Consulltant and was interviewed in Sep 2024. There was 1 interview round.
Pump head loss calculation parameters include friction loss, elevation change, velocity head, and fittings.
Friction loss due to pipe roughness
Elevation change between inlet and outlet
Velocity head due to fluid velocity
Losses from fittings like elbows, tees, and valves
AHU components refer to the various parts of an Air Handling Unit that work together to regulate and circulate air in a building.
Filters - to remove dust and particles from the air
Coils - for heating or cooling the air
Fans - to circulate the air
Dampers - to control the flow of air
Humidifiers/dehumidifiers - to adjust the humidity levels
Centrifugal blowers are commonly used in AHUs for their efficiency and ability to handle high volumes of air.
Centrifugal blowers are preferred for AHUs due to their ability to handle high volumes of air efficiently.
They are more energy efficient compared to other types of blowers.
Examples of centrifugal blowers commonly used in AHUs include forward curved, backward inclined, and airfoil designs.
Primary pump is the main pump responsible for the majority of the pumping work, while secondary pump is a backup pump used in case the primary pump fails.
Primary pump is the main pump in a system, while secondary pump is a backup pump.
Primary pump is responsible for the majority of the pumping work, while secondary pump is used only when needed.
Examples: In a heating system, the primary pump circulates hot water throug...
AHU valve connection refers to the connection of valves in an air handling unit for controlling the flow of air.
AHU valve connection is essential for regulating the flow of air in an air handling unit.
Valves are typically connected to the AHU ductwork to control the amount of air entering or exiting the unit.
Properly connected valves ensure efficient operation of the AHU system.
Examples of AHU valves include damper val
Chilled water pipe size requirements depend on flow rate, pressure drop, material, insulation, and system design.
Flow rate: Determine the required flow rate of chilled water in the system.
Pressure drop: Calculate the pressure drop to ensure efficient operation.
Material: Select appropriate pipe material based on temperature and pressure requirements.
Insulation: Insulate the pipes to prevent heat gain or loss.
System desi...
The chiller connection refers to the method by which a chiller unit is connected to a building's HVAC system.
Chiller connection typically involves piping to transport chilled water from the chiller to the building's air handling units.
The connection may also include electrical wiring for power supply and control signals.
Proper chiller connection is crucial for efficient cooling and proper functioning of the HVAC system
I applied via campus placement at Dr BR Ambedkar Government Polytechnic, Andaman And Nicobar Islands and was interviewed in Oct 2024. There was 1 interview round.
I applied via Company Website and was interviewed in Jul 2024. There were 3 interview rounds.
Is their has 30 min to solve 30 question
and topic has the check English , English Grammar
Check the code of Python and Data Science program
It also has 30 min and 30 Question
List is mutable, Tuple is immutable in Python.
List can be modified after creation, Tuple cannot be modified.
List is defined using square brackets [], Tuple is defined using parentheses ().
List is used for collections of items that may change, Tuple is used for fixed collections.
Example: list_example = [1, 2, 3], tuple_example = (4, 5, 6)
Yes, logistic regression can be used for multi class classification by using techniques like one-vs-rest or softmax.
Logistic regression is typically used for binary classification, but it can be extended to handle multiple classes.
One common approach is to use one-vs-rest (OvR) strategy, where a separate binary logistic regression model is trained for each class.
Another approach is to use softmax regression, which is a...
Built-in data refers to pre-existing datasets or information that is already included in a software or system.
Built-in data is typically provided by the software or system for analysis or processing.
Examples include sample datasets in statistical software like R or Python libraries like scikit-learn.
Built-in data can also refer to default datasets in databases or data warehouses.
It can save time and effort by providing
Decorators in Python are functions that modify the behavior of other functions.
Decorators are denoted by the @ symbol followed by the decorator name.
They are commonly used for logging, timing, authentication, etc.
Decorators can be used to add functionality to existing functions without modifying their code.
A lambda function is a small anonymous function defined without a name.
Lambda functions are used for creating small, one-time use functions.
They can take any number of arguments, but can only have one expression.
Lambda functions are often used in conjunction with higher-order functions like map, filter, and reduce.
Example: lambda x: x*2 defines a lambda function that doubles the input x.
Sterling & Wilson interview questions for popular designations
I applied via campus placement at Malla Reddy Engineering College, Ranga Reddy and was interviewed in May 2024. There were 2 interview rounds.
Total enf for a certain conditions refers to the total energy consumption for specific circumstances.
Calculate the total energy consumption by summing up the individual energy consumption values for each condition.
Consider factors such as duration, power rating, and efficiency when calculating total energy consumption.
Example: Total energy consumption for a week of running a 100W light bulb for 8 hours a day.
Get interview-ready with Top Sterling & Wilson Interview Questions
I applied via Approached by Company and was interviewed in Jun 2024. There was 1 interview round.
Slump cone top diameter is the diameter of the top opening of a slump cone used to measure the consistency of concrete.
Slump cone top diameter is typically around 4 inches.
It is an important factor in determining the workability of concrete.
The slump cone test involves filling the cone with concrete, then lifting the cone to see how much the concrete slumps.
A larger top diameter of the slump cone indicates a higher wor
The M30 concrete compressive strength is typically around 30 MPa.
M30 concrete is a mix design with a characteristic compressive strength of 30 MPa.
It is commonly used in construction for various structural elements.
The strength of M30 concrete can vary based on factors like water-cement ratio, curing conditions, and quality of materials.
I applied via Recruitment Consulltant and was interviewed in Feb 2024. There was 1 interview round.
CAD is 2D design software while BIM is 3D modeling software with added information for building components.
CAD (Computer-Aided Design) is primarily used for 2D drafting and design.
BIM (Building Information Modeling) is used for 3D modeling with added information about building components such as materials, dimensions, and costs.
CAD focuses on individual drawings or components, while BIM allows for a more holistic view ...
Prepare an rvt family by creating a new family template, setting up parameters, adding necessary components, and testing for functionality.
Create a new family template in Revit
Set up parameters for the family
Add necessary components such as geometry, dimensions, and materials
Test the family for functionality within a project
Supporting BIM files on the construction site involves ensuring access, coordination, and utilization of the digital models for efficient project management.
Provide training to on-site staff on how to access and use BIM files
Ensure all stakeholders have access to the most updated BIM files
Coordinate with subcontractors to integrate their models into the overall BIM model
Use BIM for clash detection and coordination meet...
I applied via Approached by Company and was interviewed in Jun 2024. There was 1 interview round.
The top diameter of a slump cone is typically 4 inches.
The top diameter of a slump cone is usually 4 inches.
The slump cone is used to measure the consistency of fresh concrete.
The top diameter of the slump cone affects the flow of the concrete mix.
A larger top diameter will result in a higher slump value.
Thermo-Mechanically Treated
TMT stands for Thermo-Mechanically Treated
TMT bars are commonly used in construction for reinforcement
The process involves heating the steel bars and then rapidly cooling them to increase their strength
I applied via Approached by Company and was interviewed in Aug 2024. There was 1 interview round.
I applied via Naukri.com and was interviewed in Nov 2023. There was 1 interview round.
A control module is a device that manages and regulates the operation of a system, while a relay module is a device that controls the flow of electrical current.
Control modules are responsible for monitoring and adjusting various parameters in a system, such as temperature, pressure, or speed.
Relay modules act as switches that open or close circuits to control the flow of electrical current.
Control modules are typicall...
The system architecture of FAS (Fire Alarm System) and BMS (Building Management System) involves the integration of various components and subsystems to ensure efficient monitoring and control of fire safety and building operations.
FAS system architecture typically includes fire detectors, control panels, notification devices, and communication interfaces.
BMS system architecture typically includes sensors, controllers,...
BOQ quantity for FAS system can be calculated by determining the required components and their quantities.
Identify the components needed for the FAS system
Determine the quantity of each component required based on project specifications
Consider factors such as system size, layout, and design requirements
Calculate the total quantity by summing up the quantities of all components
Example: If the FAS system requires 10 smo...
Interview experience
based on 1.6k reviews
Rating in categories
Electrical Engineer
270
salaries
| ₹1.8 L/yr - ₹7.6 L/yr |
Senior Engineer
240
salaries
| ₹3.1 L/yr - ₹10 L/yr |
Project Engineer
218
salaries
| ₹2.4 L/yr - ₹8.5 L/yr |
Assistant Manager
187
salaries
| ₹4.1 L/yr - ₹15.5 L/yr |
Deputy Manager
143
salaries
| ₹5.7 L/yr - ₹18 L/yr |
Larsen & Toubro Limited
Tata Power
Thermax Limited
BHEL