i
Reliance Industries
Proud winner of ABECA 2024 - AmbitionBox Employee Choice Awards
Filter interviews by
I applied via LinkedIn and was interviewed in Mar 2023. There were 2 interview rounds.
Transformer loss refers to the energy that is dissipated as heat in a transformer during the process of converting electrical energy from one voltage level to another.
Transformer loss includes copper loss (I²R loss) in the windings and core loss (eddy current and hysteresis losses) in the transformer core.
Copper loss occurs due to the resistance of the copper windings, leading to heat generation.
Core loss is caused by ...
The type of relay used in switchyard and line is a protective relay.
Protective relays are used to detect abnormal conditions in the electrical system and initiate corrective actions.
Common types of protective relays include overcurrent relays, distance relays, and differential relays.
These relays help to protect equipment and prevent damage to the electrical system.
Examples of relay manufacturers include Siemens, ABB,
Pilotwire relay is a device used in electrical systems to detect faults and isolate them to prevent damage.
Pilotwire relay is a protective relay used in power systems.
It operates by detecting abnormal conditions such as overcurrent or short circuits.
Once a fault is detected, the pilotwire relay sends a signal to trip the circuit breaker and isolate the fault.
It helps in preventing damage to equipment and ensuring safet...
Substation capacity can be decided based on load demand, future growth projections, available space, and budget constraints.
Consider current load demand to determine initial capacity requirements
Factor in future growth projections to ensure capacity will meet long-term needs
Evaluate available space for equipment installation and expansion
Take budget constraints into account when selecting substation capacity
Consult wit...
Oil test for transformers is a diagnostic test to assess the condition of the insulating oil used in transformers.
Oil test helps in detecting any contamination or degradation of the insulating oil.
Common oil tests include Dissolved Gas Analysis (DGA), Dielectric Strength Test, and Water Content Test.
Results of oil tests can indicate potential issues with the transformer, such as overheating or insulation breakdown.
Regu...
The first pole to clear factor of a breaker is the time it takes for the breaker to trip and disconnect the circuit in case of a fault.
The first pole to clear factor is the time delay of the breaker.
Shorter time delays indicate faster tripping of the breaker in case of a fault.
Factors affecting the first pole to clear include the type of fault, current magnitude, and breaker design.
For example, a high current fault may...
I coordinate relay by ensuring clear communication, setting timelines, assigning tasks, and monitoring progress.
Clear communication with all team members involved
Setting clear timelines and deadlines for each task
Assigning specific tasks to team members based on their strengths and expertise
Regularly monitoring progress and providing support or guidance as needed
LBB Protection stands for Life, Body, and Business Protection. It refers to insurance policies that provide coverage for individuals and businesses in case of unexpected events.
LBB Protection includes life insurance, health insurance, disability insurance, and business insurance.
Life insurance provides financial protection to the family in case of the policyholder's death.
Health insurance covers medical expenses for il...
I appeared for an interview in Jan 2025.
I am a motivated and dedicated individual with a passion for construction management.
I have a strong background in construction and project management.
I am detail-oriented and have excellent organizational skills.
I am a team player and have experience working with diverse teams.
I am always looking for opportunities to learn and grow in the field of construction management.
There are several types of support types used for piping fixing, including clamps, hangers, and anchors.
Clamps are used to hold pipes in place and prevent movement.
Hangers are used to support the weight of the pipes from above.
Anchors are used to secure pipes to a structure to prevent movement.
Other types of support types include guides, shoes, and struts.
I have extensive experience in planning, managing, and executing various activities related to piping material issues for contracts, fabrication, welding, inspection work, and mechanical completion in the construction industry.
Engaged in planning and managing piping material issues for contracts
Worked with materials such as carbon steel, alloy steel, stainless steel, and cast iron water pipelines
Provided services invol...
I appeared for an interview in Feb 2025.
Erection and testing of transformers involves careful installation, connection, and verification of performance parameters.
1. Site Preparation: Ensure the foundation is level and capable of supporting the transformer weight.
2. Unloading: Use cranes or forklifts to safely unload the transformer from transport vehicles.
3. Positioning: Align the transformer with the designated installation area, ensuring proper clearance ...
Erecting a power panel involves careful planning, installation, and safety measures to ensure proper functionality and compliance.
1. Site Preparation: Ensure the installation site is clean, level, and free from obstructions.
2. Equipment Check: Verify that all components of the power panel are present and undamaged.
3. Mounting: Securely mount the panel to a wall or a dedicated structure using appropriate fasteners.
4. El...
Cable laying involves planning, installation, and securing cables for electrical systems, ensuring safety and efficiency.
Plan the route: Assess the area for obstacles and determine the most efficient path for the cables.
Select appropriate cables: Choose cables based on voltage, current capacity, and environmental conditions.
Use proper tools: Employ tools like cable pullers, trenchers, and splicing kits for effective in...
Generator rotor tests ensure the rotor's integrity and performance, crucial for reliable generator operation.
Visual Inspection: Check for physical damage, cracks, or corrosion on the rotor surface.
Insulation Resistance Test: Measure insulation resistance between rotor windings and ground using a megohmmeter.
Winding Resistance Test: Use a micro-ohmmeter to measure the resistance of rotor windings to ensure they are with...
Testing and commissioning of HT & LT panels ensure safety, reliability, and performance of electrical systems.
Visual Inspection: Check for physical damage, proper labeling, and cleanliness of the panel.
Insulation Resistance Testing: Use a megohmmeter to measure insulation resistance to ensure safety.
Functional Testing: Verify the operation of circuit breakers, relays, and other protective devices.
Voltage and Curren...
What people are saying about Reliance Industries
I applied via Company Website and was interviewed in Dec 2024. There were 4 interview rounds.
Denier doff shedule wise daily routine test, new pack change test, abnormal test. Denier change test. Special sample test daily schedule wise test following
Testing purpose group discussion and best quality this product and best opportunity
Denier doff shedule and new pack test and and PQC proper testing par shift wise follow up
Reliance Industries interview questions for popular designations
I appeared for an interview in Jan 2025.
Get interview-ready with Top Reliance Industries Interview Questions
I appeared for an interview in Jan 2025.
I appeared for an interview in Feb 2025.
I have extensive experience in team management, customer service, and operational efficiency, making me a strong candidate for this role.
Managed a team of 15 in a fast-paced environment, improving productivity by 20%.
Implemented a new scheduling system that reduced customer wait times by 30%.
Trained staff on customer service best practices, resulting in a 95% satisfaction rating.
Conducted regular performance reviews to
Group discussion with HR.
General aptitude, basic Maths and English
I appeared for an interview in Mar 2025, where I was asked the following questions.
I lead my security team by fostering communication, training, and proactive measures to ensure a safe environment.
Establish clear communication channels: Regular team meetings to discuss updates and concerns.
Implement training programs: Conduct drills and workshops to keep the team prepared for various scenarios.
Encourage teamwork: Foster a collaborative environment where team members support each other.
Utilize technol...
I appeared for an interview in Feb 2025.
The duration of Reliance Industries interview process can vary, but typically it takes about less than 2 weeks to complete.
based on 1.2k interviews
Interview experience
based on 16.6k reviews
Rating in categories
Manager
3.4k
salaries
| ₹5.4 L/yr - ₹19.4 L/yr |
Field Executive
2.7k
salaries
| ₹1.8 L/yr - ₹9.5 L/yr |
Assistant Manager
2.7k
salaries
| ₹1.8 L/yr - ₹10 L/yr |
Senior Manager
2.5k
salaries
| ₹8 L/yr - ₹28 L/yr |
Deputy Manager
1.2k
salaries
| ₹3.5 L/yr - ₹14 L/yr |
Indian Oil Corporation
Shell
Bharat Petroleum
Hindustan Petroleum