Industrial compressors work by increasing the pressure of a gas to create mechanical energy.
Industrial compressors use a motor to draw in and compress gas, then release it at a higher pressure.
The compressed gas can be used for various industrial applications such as powering pneumatic tools or HVAC systems.
Common types of industrial compressors include reciprocating, rotary screw, and centrifugal compressors.
The overhauling procedure of a centrifugal pump involves disassembling, inspecting, repairing/replacing components, and reassembling the pump.
Start by shutting off power to the pump and draining the system
Remove the pump casing and impeller to access internal components
Inspect components for wear, damage, or corrosion
Repair or replace damaged components such as bearings, seals, or impeller
Reassemble the pump, ensuring ...
I applied via Approached by Company and was interviewed in Aug 2024. There were 2 interview rounds.
Any type of work to be solved within the time limit.
Accounting and office administration involve managing financial records, budgets, and office operations.
Maintaining accurate financial records
Preparing financial statements and reports
Managing budgets and expenses
Handling payroll and invoicing
Organizing office operations and procedures
I applied via Recruitment Consulltant and was interviewed in Jun 2024. There was 1 interview round.
The power flow at my previous company involved analyzing and optimizing the distribution of electrical power throughout the system.
Studied power flow patterns to ensure efficient distribution of electricity
Utilized software like ETAP or PSS/E for power flow analysis
Implemented measures to reduce power losses and improve system reliability
Collaborated with other engineers to address power flow issues
Regularly monitored
Operation and maintenance procedures for transformer feeders and motor feeders involve regular inspections, testing, and preventive maintenance to ensure optimal performance and safety.
Regularly inspect transformer and motor feeders for signs of wear, damage, or overheating.
Perform routine testing to check for proper voltage levels, insulation resistance, and overall functionality.
Conduct preventive maintenance such as...
A contactor is an electrical device used to switch an electrical circuit on or off, while BMR stands for Basic Maintenance Ratio in electrical engineering.
Contactor is used to control electric motors, lighting, heating, and other electrical loads
BMR is a ratio used to determine the maintenance cost of a system relative to its initial cost
Contactor typically consists of a coil, contacts, and an enclosure
BMR is calculate...
Low forward power in a generator refers to the situation where the power output of the generator is lower than expected or required.
Low forward power can be caused by issues such as mechanical problems, fuel supply issues, or electrical faults.
It can result in reduced efficiency, poor performance, and potential damage to the generator.
Regular maintenance and monitoring can help prevent and address low forward power iss...
To sync your power plant with the grid, you need to match the frequency and phase of the plant with the grid.
Ensure the frequency of the power plant matches the grid frequency (usually 50 or 60 Hz)
Synchronize the phase angle of the power plant with the grid
Use synchronization equipment such as synchronizing relays and synchroscopes
Gradually increase the power output of the plant to match the grid demand
Monitor the sync
What people are saying about Reliance Industries
I was interviewed in Jul 2024.
Aptitude, logical reasoning, and core competencies.
I have completed training in various engineering concepts and have worked on projects involving design, analysis, and implementation.
Completed training in CAD software for designing mechanical components
Worked on a project to optimize energy consumption in a manufacturing plant
Implemented a new control system for a robotic arm in a research project
Shear force and bending moment diagrams are graphical representations of internal forces in a structural element.
Shear force diagram shows the variation of shear force along the length of the beam.
Bending moment diagram shows the variation of bending moment along the length of the beam.
Shear force is the force that acts parallel to the cross-section of the beam, while bending moment is the moment that causes bending of...
Tests of bricks and cement are essential for ensuring quality and durability in construction projects.
Bricks can be tested for compressive strength, water absorption, efflorescence, and dimensions.
Cement can be tested for fineness, setting time, compressive strength, and soundness.
Various standard tests like compressive strength test, water absorption test, and soundness test are conducted to assess the quality of bric...
Reliance Industries interview questions for popular designations
I applied via Company Website and was interviewed in Mar 2024. There were 2 interview rounds.
Gear box replacement work
Get interview-ready with Top Reliance Industries Interview Questions
ROI analysis involves evaluating the return on investment for a particular project or initiative.
Calculate ROI by dividing the net profit of the investment by the initial cost of the investment.
Example: If a company invests $10,000 in a marketing campaign and generates $50,000 in revenue, the ROI would be ($50,000 - $10,000) / $10,000 = 4 or 400%.
ROI analysis helps in determining the effectiveness and profitability of ...
ROI, how to cope up problem.situation solution
I was interviewed in Sep 2024.
Questions were basic and should have very clear and precise knowledge about the topics.
Inrush current is the high current drawn by an electrical device when it is first turned on.
Inrush current occurs when the impedance of the device is low at startup, causing a surge in current flow.
It can cause voltage drops, tripping of circuit breakers, and damage to components.
Common examples include when a motor starts up or when a power supply is turned on.
Symmetrical faults have balanced currents and voltages, while unsymmetrical faults have unbalanced currents and voltages.
Symmetrical faults have equal currents and voltages on all phases, such as three-phase short circuit faults.
Unsymmetrical faults have different currents and voltages on different phases, such as single-phase faults or line-to-ground faults.
Symmetrical faults are easier to analyze and protect against ...
I applied via Company Website and was interviewed in Aug 2024. There was 1 interview round.
posted on 30 Oct 2024
Related to branch + general maths
Heat treatment process involves heating and cooling metals to alter their physical and mechanical properties.
Heating the metal to a specific temperature
Holding the metal at that temperature for a certain period of time
Cooling the metal at a controlled rate
Types of heat treatment include annealing, tempering, quenching, and normalizing
I applied via LinkedIn and was interviewed in Aug 2024. There were 2 interview rounds.
The duration of Reliance Industries interview process can vary, but typically it takes about less than 2 weeks to complete.
based on 1.2k interviews
Interview experience
based on 16.1k reviews
Rating in categories
Navi Mumbai
5-10 Yrs
Not Disclosed
Navi Mumbai
3-8 Yrs
Not Disclosed
Manager
3.4k
salaries
| â‚ą0 L/yr - â‚ą0 L/yr |
Field Executive
2.7k
salaries
| â‚ą0 L/yr - â‚ą0 L/yr |
Assistant Manager
2.7k
salaries
| â‚ą0 L/yr - â‚ą0 L/yr |
Senior Manager
2.5k
salaries
| â‚ą0 L/yr - â‚ą0 L/yr |
Deputy Manager
1.1k
salaries
| â‚ą0 L/yr - â‚ą0 L/yr |
Tata Group
Adani Group
Hindustan Unilever
Bharti Enterprises