Erection and testing of transformers involves careful installation, connection, and verification of performance parameters.
1. Site Preparation: Ensure the foundation is level and capable of supporting the transformer weight.
2. Unloading: Use cranes or forklifts to safely unload the transformer from transport vehicles.
3. Positioning: Align the transformer with the designated installation area, ensuring proper clearance ...
Erecting a power panel involves careful planning, installation, and safety measures to ensure proper functionality and compliance.
1. Site Preparation: Ensure the installation site is clean, level, and free from obstructions.
2. Equipment Check: Verify that all components of the power panel are present and undamaged.
3. Mounting: Securely mount the panel to a wall or a dedicated structure using appropriate fasteners.
4. El...
Cable laying involves planning, installation, and securing cables for electrical systems, ensuring safety and efficiency.
Plan the route: Assess the area for obstacles and determine the most efficient path for the cables.
Select appropriate cables: Choose cables based on voltage, current capacity, and environmental conditions.
Use proper tools: Employ tools like cable pullers, trenchers, and splicing kits for effective in...
Generator rotor tests ensure the rotor's integrity and performance, crucial for reliable generator operation.
Visual Inspection: Check for physical damage, cracks, or corrosion on the rotor surface.
Insulation Resistance Test: Measure insulation resistance between rotor windings and ground using a megohmmeter.
Winding Resistance Test: Use a micro-ohmmeter to measure the resistance of rotor windings to ensure they are with...
Testing and commissioning of HT & LT panels ensure safety, reliability, and performance of electrical systems.
Visual Inspection: Check for physical damage, proper labeling, and cleanliness of the panel.
Insulation Resistance Testing: Use a megohmmeter to measure insulation resistance to ensure safety.
Functional Testing: Verify the operation of circuit breakers, relays, and other protective devices.
Voltage and Curren...
I design, develop, and test electrical systems and equipment.
Designing electrical systems for buildings or products
Developing prototypes and testing them for functionality
Collaborating with other engineers and technicians
Troubleshooting and resolving electrical issues
Staying updated on industry trends and advancements
I applied via Recruitment Consulltant and was interviewed in Dec 2023. There was 1 interview round.
What people are saying about Reliance Industries
I applied via Company Website and was interviewed in Apr 2023. There were 2 interview rounds.
Reliance Industries interview questions for designations
I applied via Company Website and was interviewed in Mar 2023. There were 3 interview rounds.
Electrical maintenance sap work manpower cordinet
Get interview-ready with Top Reliance Industries Interview Questions
I was interviewed before Feb 2024.
Electrical Equipment & sld of the compaany
I am a dedicated Electrical Engineer with a strong background in designing and implementing electrical systems.
Graduated with a degree in Electrical Engineering from XYZ University
Experienced in designing and testing electrical systems for commercial buildings
Proficient in using CAD software for schematic design
Strong problem-solving skills and attention to detail
Completed internships at ABC Company and gained hands-on
I applied via Approached by Company and was interviewed before Jan 2023. There were 2 interview rounds.
I applied via Campus Placement and was interviewed in Oct 2021. There was 1 interview round.
Ohm's law states that the current through a conductor between two points is directly proportional to the voltage across the two points.
Ohm's law is represented by the equation I = V/R, where I is the current, V is the voltage, and R is the resistance.
It is used to calculate the current flowing through a circuit given the voltage and resistance.
It can also be used to calculate the resistance of a circuit given the volta...
A relay is an electrically operated switch that uses an electromagnet to mechanically control the opening and closing of contacts.
Relays are commonly used in electrical systems to control high-power devices with low-power signals.
They can be used to control motors, lights, solenoids, and other electrical components.
Relays have an input coil that generates a magnetic field when current flows through it, causing the cont...
I applied via Naukri.com and was interviewed in Jun 2021. There were 3 interview rounds.
based on 17 interviews
2 Interview rounds
based on 107 reviews
Rating in categories
Manager
3.4k
salaries
| ₹0 L/yr - ₹0 L/yr |
Field Executive
2.7k
salaries
| ₹0 L/yr - ₹0 L/yr |
Assistant Manager
2.7k
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Manager
2.5k
salaries
| ₹0 L/yr - ₹0 L/yr |
Deputy Manager
1.1k
salaries
| ₹0 L/yr - ₹0 L/yr |
Tata Group
Adani Group
Hindustan Unilever
Bharti Enterprises